Troubleshooting ServeRAID controller issues

Troubleshooting


Problem

ServeRAID controller troubleshooting information

Resolving The Problem

Note: ServeRAID controllers in cluster or fault-tolerant environments require additional troubleshooting techniques which are detailed in the User's Reference (SRAID.PDF) contained in the BOOKS directory of the ServeRAID Support CD.

If you need definitions:

  1. To begin troubleshooting, check the following top issues. If your issue is listed, select the link, otherwise proceed to step 2.

    Bad Stripe table entries
    DDD - Recovery from a single disk drive failure
    DDD - Recovery from multiple disk drive failures
    Drive(s) not responding or found in new location bootup error
    Erratic system performance, DDD, lost configuration, or errors
    Force flashing firmware causes configuration problems
    Logical drive migration (changing RAID level, or adding drives)
    Operating system crashes after hot-swap HDD replacement
    POST error 1801 when multiple RAID adapters installed
    Predictive Failure Analysis (PFA) alert on HDD
    Startup error messages
    ServeRAID-7t SATA controller overview
    ServeRAID and SCSI controller sales and marketing


  2. Ensure you are using the latest ServeRAID software code.

  3. Check for any known RETAIN tips for your controller

  4. Capture the ServeRAID logs to send to the Support Center if you need further assistance. Flashing the ServeRAID controller will erase the ServeRAID logs, so make sure to obtain these before flashing the adapter.

    How to Capture the ServeRAID configuration and event logs

  5. Ensure that all hard disks are replaced according to IBM procedures and guidelines, see "Removing ServeRAID hot-swap hard disk drives improperly may cause damage"

  6. If these steps have not solved your problem:
    Refer to your system's Hardware Maintenance Manual, or refer to "Need more help?"

Need more help?
Please select one of the the following options for further assistance:

//www.ibm.com/i/v14/icons/fw.gif Support forums
//www.ibm.com/i/v14/icons/fw.gif Submit a technical question
Before you call IBM Service

 

Document Location

Worldwide

Operating System

System x Hardware Options:Operating system independent / None