IOSHC099I
CHECK(IBMIOS,IOS_DYNAMIC_ROUTING) cannot be processed because
an unexpected error in module modname.Diagnosis
area:diagnostic-data
IOSHC100I
Captured UCB protection is currently state and
in the expected state.
IOSHC101E
Captured UCB overlay protection is expected to be expect but
is actually actual.
IOSHC102I
31-bit IOS blocks are currently
state and in the
expected state.
IOSHC103E
31-bit IOS blocks are expected to be expect but
are actually actual.
IOSHC104I
The MIDAW facility is currently
state and in the expected
state.
IOSHC105E
The MIDAW facility is expected to be expect but
is actually actual.
IOSHC106I
The MIDAW facility is not available on this processor.
IOSHC110I
No command response (CMR) time exceptions have been detected.
IOSHC111I
Check results may be based on previous parameter values.
New parameters will take effect the next time control unit data is
gathered.
IOSHC112E
Analysis of command response (CMR) time detected one or more
control units with an exception.
IOSHC113I
Command Response Time ReportThe following control
units show inconsistent average command response (CMR) time based
on these parameters: THRESHOLD = thresholdRATIO
= x CMR TIME EXCEPTION
DETECTED AT: timeCONTROL UNIT = cuND
= node ENTRY EXIT CU I/O AVG CHPID LINK LINK INTF RATE CMR chpid el dl intf iort cmr chpid el dl intf iort cmr
IOSHC117I
No fabric health exceptions have been detected.
IOSHC120I
Fabric Health ReportThe following fabric health
issues have been detected:Fabric health exception detected
at: mm/dd/yyyy hh.mm.ss.nnnCHPID= cc Entry
link=el Exit link=dl Suspect
port=s-portSource to
destination routing information follows:Switch
Domain=dd, Type=director-type
GroupPort Type From To
Agg Dyn Speed Miscaa Entry Chan Chan nn nn xxxG
Dynamic Exit CU CU .. .. Static
Alt=nn ddaa ddaa Agg-nn
Agg-nn Mult Dyn-nnHealth
information follows:Fabric Health=fabric-health-infoSwitch
Domain=dd, Health=switch-health-info
%Util %Delay Error Count Opt SignalPort
Health Trn/Rcv Trn/Rcv Trn/Recv Trn/Recvaa
health-info nnn/nnn nnn/nnn nnnnn/nnnnn ±nnnn/±nnnn
IOSHC130I
No I/O rate exceptions have been detected
IOSHC131I
Check results may be based on previous parameter values.
New parameters will take effect the next time control unit data is
gathered.
IOSHC132E
Analysis of I/O rates detected one or more control units
with an exception.
IOSHC133I
I/O Rate Report The following control units
show inconsistent I/O rates based on these parameters: THRESHOLD
= thresholdRATIO = ratioI/O
RATE EXCEPTION DETECTED AT: timeCONTROL
UNIT = cu ND = node
ENTRY EXIT CU I/O AVG IOR CHPID LINK
LINK INTF RATE CMR EXC chpid el dl intf
iort cmr chpid el dl intf iort cmr
exc
IOSHC140I
Dynamic routing is not enabled in the SAN
IOSHC141I
Dynamic routing is enabled in the SAN and no inconsistencies
were detected
IOSHC142E
Dynamic routing inconsistencies were detected
IOSHC143I
Dynamic routing is enabled in the SAN but not supported by
the processor
IOSHC144I
Dynamic routing is enabled in the SAN but not supported by
the following controller(s):
IOSHC145I
The following do not support dynamic routing. This is allowed
in the current environment, however it could result in I/O errors
if dynamic routing were to be enabled in the SAN.