IOS564I
ACTIVE TELEPROCESSING DEVICE

Explanation

The operator entered a command to vary a path online for one of the following teleprocessing devices:
  • 2701
  • 2702
  • 2703

The device was active, but the system could not validate the device.

System action

The system does not vary the path online.

Operator response

Wait for I/O activity to the device to complete. Enter the command again.

Source

Input/output supervisor (IOS)

Module

IECVIOPM

Routing code

1

Descriptor code

4