IOS092I
[INITIALIZATION ESTAE FAILED | INTERNAL PROCESSING ERROR] MIH NOT {RUNNING | UPDATED}

Explanation

In response to the SET IOS=xx or SETIOS MIH,… command, the system displays this message.

The message text contains one of the following variations:
INITIALIZATION ESTAE FAILED, MIH NOT RUNNING
The system did not start any timers at system initialization.
INITIALIZATION ESTAE FAILED, MIH NOT UPDATED
The SET or SETIOS command produced no changes.
INTERNAL PROCESSING ERROR, MIH NOT RUNNING
An internal error occurred at system initialization. The system may not have started one or more timers.
INTERNAL PROCESSING ERROR, MIH NOT UPDATED
During command processing, an internal error occurred.

System action

If NOT RUNNING appears in the message text, the system does not monitor devices. If NOT UPDATED appears, the system continues to monitor devices.

Operator response

Use the DISPLAY command to determine the state of the missing interrupt handler (MIH). Notify the system programmer.

System programmer response

Search problem reporting databases for a fix for the problem. If no fix exists, contact the IBM® Support Center.

Source

Input/output supervisor (IOS)