z/OS MVS System Messages, Vol 5 (EDG-GFS)
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


EDG6425E

z/OS MVS System Messages, Vol 5 (EDG-GFS)
SA38-0672-00

EDG6425E
JOURNAL INPUT CONTAINS DATA SETS OUT OF SEQUENCE - CONCATENATION NUMBER number

Explanation

During EDGBKUP recovery of the DFSMSrmm control data set, DFSMSrmm found that the journal consisted of concatenated, multiple data sets, and that the correct concatenation sequence has not been used.

This is the result of either using the wrong journal backups or the wrong data set sequence.

In the message text:
number
The number of the data set in the list of concatenated data sets. The first data set in the list is concatenation number 0.

During SMFIN forward recovery, journal records are created from SMF records. This might have caused the JOURNAL DD entry specified in the message to have been created.

System action

The EDGBKUP utility continues with the forward recovery request, sets return code 8, and updates the control records of the recovered DFSMSrmm control data set to indicate recovery is in error.

Operator response

None.

System programmer response

Check that the correct journal backup copies have been used for this recovery request. Ignore this error if you understand exactly why the situation has happened. For example, you might have lost a particular backup of the journal. If you are not expecting the error, you should select the correct backups and retry recovery. Run the EDGUTIL utility with VERIFY(ALL). When this completes with return code zero, the DFSMSrmm control data set error indicators are reset.

Source

DFSMSrmm

Module

EDGBKUP

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2014