EDG6425E z/OS MVS System Messages, Vol 5 (EDG-GFS) SA38-0672-00 |
|
EDG6425E JOURNAL INPUT CONTAINS DATA SETS OUT OF SEQUENCE - CONCATENATION
NUMBER number ExplanationDuring EDGBKUP recovery of the DFSMSrmm control data set, DFSMSrmm found that the journal consisted of concatenated, multiple data sets, and that the correct concatenation sequence has not been used. This is the result of either using the wrong journal backups or the wrong data set sequence. In the message
text:
During SMFIN forward recovery, journal records are created from SMF records. This might have caused the JOURNAL DD entry specified in the message to have been created. System actionThe EDGBKUP utility continues with the forward recovery request, sets return code 8, and updates the control records of the recovered DFSMSrmm control data set to indicate recovery is in error. Operator responseNone. System programmer responseCheck that the correct journal backup copies have been used for this recovery request. Ignore this error if you understand exactly why the situation has happened. For example, you might have lost a particular backup of the journal. If you are not expecting the error, you should select the correct backups and retry recovery. Run the EDGUTIL utility with VERIFY(ALL). When this completes with return code zero, the DFSMSrmm control data set error indicators are reset. SourceDFSMSrmm ModuleEDGBKUP |