CBR4453I Unknown pseudo-library name plibrary-name specified for volume volser. The current library name for this volume is olibrary-name.
Explanation
An invalid pseudo-library name was detected when
demounting volume volser from an operator accessible
drive. One of the following statements is true for the pseudo-library
name plibrary-name associated with this volser:
- The plibrary-name is blank.
- The plibrary-name is not defined in the SMS ACDS.
System action
The volume is demounted from the operator accessible drive, but the volume, and its opposite side, are marked as LOST volumes. The volume and its opposite side will not be used until the LOST flag has been cleared and the pseudo-library name has been reset.
Operator response
Notify the system programmer.
System programmer response
The plibrary-name contains the value in the PLIBARY column of the DB2® VOLUME table for the row associated with this volser. The olibrary-name contains the value in the OLIBARY column of the DB2 VOLUME table for the row associated with this volser.
If
the olibrary-name displayed in message CBR4453I
is a real library (not a pseudo library), you can use either of the
following actions to clear the LOST flag and reset the pseudo-library
associated with this volser and its opposite side:
- Enter the cartridge into the real optical library specified by olibrary-name. Cartridge entry clears the LOST flag, and the PLIBRARY will be set at the time the volume is ejected from the real library. The volume can be used as soon as cartridge entry has completed.
- Perform a REMAP on the real optical library identified by olibrary-name. The remap will result in synching up the volume's LOCATION, PLIBRARY and OLIBRARY values in the DB2 VOLUME table for both sides of the platter.
The following alternative method for clearing this condition
can be used regardless of whether the library identified by olibary-name is
a real library or not.
- Stop OAM and SPUFI the OLIBRARY and PLIBRARY values to a valid
pseudo-library name and LOCATION to 'S' in the rows associated with
this volser and its opposite side in the VOLUME
table of the DB2 optical configuration
database, and then start OAM. Note: For shelf resident volumes, both the OLIBRARY and PLIBRARY values should have the same pseudo-library name.
Source
Object Access Method (OAM)
Routing Code
2
Descriptor Code
4