CBR6221I   Volume volser-1 in library library-name audited. Wrong volume volser-2 found in slot.

Explanation

Volume volser-1 was audited. Volume volser-2 was found in the slot where volser-1 should have been. If the audit request originated in ISMF, this message is issued to the TSO user ID of the storage administrator who initiated the audit request.

In the message text:
volser-1
The volume serial number that was requested for audit.
volser-2
The volume serial number of the volume found in volser-1's slot.
library-name
The library name.

System action

The volume error status fields for volume volser-1 and volume volser-2 are updated to reflect the error.

System programmer response

Audit volume volser-2 because the cartridges may have been swapped. If this is the case, issuing remap for the library will correct this problem.

Source

Object Access Method (OAM)

Routing Code

2,3,4,5,6

Descriptor Code

4