CBR4426D Mount pending for volume volser on drive drive-name. Reply 'R' to retry or 'C' to cancel this request.
Explanation
An OAM cartridge insertion pending time limit has been exceeded. OAM has requested a cartridge load into a drive and has not been able to detect this load.
System action
OAM processing waits for a response from the operator.
Operator response
If OAM cancels this request, reply 'C' to
this message. OAM processing continues and the application that is
requesting this mount is informed. Note that if the operator responds
with 'C,' the volume volser will be marked lost, and no more
requests that require this volume will be done until the
MODIFY OAM,UPDATE,VOLUME,volser,LOSTFLAG,OFF
command
is issued, or the OAM address space is stopped and restarted to clear
the lost status that is associated with this volume.In some cases this message will be preceded by CBR4442I (the volume is being reinitialized). Canceling the mount during a reinitialization will result in both sides of the cartridge having to be reinitialized the next time the cartridge is mounted.
If OAM should continue the load request for this volume, reply 'R' to this message.
Review message CBR4400A, CBR4413I or CBR4430A for the mount request.
Source
Object Access Method (OAM)
Routing Code
2, 4, 6
Descriptor Code
2