CBR4113I   No libraries defined to AOM.

Explanation

An error has been detected during Library Automation Communication Services (LACS) processing for the MOUNT or DEMOUNT function. The asynchronous operations manager (AOM) has rejected the mount or demount order with an indication that no libraries have been defined to AOM. Synchronization has been lost between the caller of LACS and AOM.

System action

LACS is abnormally terminated with system completion code 0B6-1C. When execution resumes following the ABEND, the LACS request fails with a permanent error return code. Messages issued by the caller of LACS are written concurrently with this message.

Operator response

Contact the system programmer.

System programmer response

Follow the instructions for system completion code 0B6.

Source

Object Access Method (OAM)

Routing Code

Set by the caller.

Descriptor Code

Set by the caller.