CBR3713I Permanent I/O error in library library-name, for volume volser. Sense not available.
Explanation
An error has been detected during processing of
volume volser in library library-name,
which returned a permanent I/O error. Library sense information is
not available. One of the following situations exists:
- The error was not a unit check.
- The error was a unit check, but the sense record could not be read.
- The sense record did not describe a library related error.
System action
The library request fails. OAM processing continues.
System programmer response
Search problem reporting databases for a fix for the problem. If no fix exists, contact the IBM® Support Center to report the permanent I/O error. Resubmit the library request when the error is corrected.
Source
Object Access Method (OAM)
Routing Code
2,3,5
Descriptor Code
4