CBR3713I   Permanent I/O error in library library-name, for volume volser. Sense not available.

Explanation

An error has been detected during processing of volume volser in library library-name, which returned a permanent I/O error. Library sense information is not available. One of the following situations exists:
  • The error was not a unit check.
  • The error was a unit check, but the sense record could not be read.
  • The sense record did not describe a library related error.

System action

The library request fails. OAM processing continues.

System programmer response

Search problem reporting databases for a fix for the problem. If no fix exists, contact the IBM® Support Center to report the permanent I/O error. Resubmit the library request when the error is corrected.

Source

Object Access Method (OAM)

Routing Code

2,3,5

Descriptor Code

4