CBR2718I   Audit request rejected. Volume volser has the wrong media type for audit processing.

Explanation

The volume information for volume volser indicates an incorrect media type for audit processing. Audit processing is performed only on volumes of cartridges stored in six models (3995-111, 3995-112, 3995-113, 3995-131, 3995-132, 3995-133) of optical disk libraries. If the audit request originated in ISMF, this message is issued to the TSO user ID of the storage administrator who initiated the audit request.

System action

OAM processing continues.

System programmer response

Display the volume using the D SMS,VOL command or, if the audit request originated in ISMF, verify that the ISMF mountable optical volume list from which the audit request was submitted is current.

Source

Object Access Method (OAM)

Routing Code

2,3,4,5,6

Descriptor Code

4