CBR2158I Eject failed for volumes volser-1 and volser-2, Return Code=return-code.
Explanation
If an optical cartridge is library
resident, it must be ejected as part of reinitialization processing
if it was one of the following:
- The source volume of a Move Volume utility with DELETE option specified.
- The source volume of a Volume Recovery utility with DELETE option specified.
- A write-once cartridge selected by the OAM Storage Management Component shelf manager for expiration.
The return code listed here is an internal OAM return code, and intended for diagnostic purposes only.
System action
The reinitialization request is failed.
System programmer response
If the problem recurs and if the program is not in error, search problem reporting databases for a fix for the problem. If no fix exists, contact the IBM® Support Center.
Source
Object Access Method (OAM)
Routing Code
2,4,6
Descriptor Code
4