CBR2001I   Volumes volser-1 and volser-2 not found in library library-name.

Explanation

OAM has attempted to mount a library-resident optical volume in order to read or write a data object on the volume. The library slot where the volume resides, according to information in the optical configuration database, is empty or contains a different volume. This error is probably the result of improper manual movement of library volumes. In the message text, volser-1 and volser-2 are replaced by the volume serial numbers of the missing volume and its opposite side volume, and library-name is replaced by the name of the library in which the volumes should reside.

System action

OAM marks the volumes lost. If the current request is non-specific, an attempt is made to locate another suitable volume. If no other volume is found, or if the current request is for the specific volume, OAM fails the request. Any future specific request for either volume fails.

Operator response

Notify the system programmer.

System programmer response

Determine where the volumes are actually located.

For 9246 libraries:
  • If the lost volumes are in a shelf location, reenter the volumes into the library in which they are needed.
  • If the lost volumes are in an offline library drive, vary the drive online. The volume and slot table entries in the optical configuration database may be incorrect. Follow the procedure for volumes in an incorrect slot.
  • If the lost volumes are in an operator accessible drive, vary the drive offline, remove the volumes from the operator accessible drive and reenter the volumes into the library in which they are needed. The volume and slot table entries in the optical configuration database may be incorrect. Follow the procedure for volumes in an incorrect slot.
  • If the lost volumes are in an incorrect slot, stop the OAM address space. Using interactive DB2® services, update the volume table and slot table entries in the optical configuration database to present the correct information. Start the OAM address space. If the volumes are in the wrong library, eject the volumes and reenter them into the library in which they are needed.
For 3995 libraries:
  • If the lost volumes are in a shelf location, reenter the volumes into the library in which they are needed.
  • If the lost volumes are in an offline library drive, vary the drive online. Perform a remap for that library.
  • If the lost volumes are in an offline operator accessible drive, vary the drive online, remove the volumes from the drive and reenter the volumes into the library in which they are needed.
  • If the volumes are in an incorrect slot, perform a remap for that library.

Source

Object Access Method (OAM)

Routing Code

4,6

Descriptor Code

4