CBR0181I   Unknown library name library-name specified for volume volser.

Explanation

One of the following statements is true for the library name library-name specified for storage group storage-group-name:
  • The library is not defined in the SMS ACDS.
  • The library definition in the SMS ACDS contained errors.
  • The library is defined in the SMS ACDS, however it is connected to more than one system in a sysplex, and this instance of OAM does not belong to an OAMplex; therefore, any optical libraries connected to more than one system are ignored.

System action

The volume is not added to the optical configuration. OAM initialization continues.

Operator response

Notify the system programmer.

System programmer response

If the library name in the volume definition is in error, correct the library name in the Volume Table in the DB2® optical configuration database, using SPUFI. If the library definition is missing from the SMS CDS, add the definition using the ISMF Storage Administrator library define panel. If the library definition is in error, follow the instructions for the message describing that error. If a new configuration is being activated, and if the volume is not to be part of that configuration, no action is necessary.

Source

Object Access Method (OAM)

Routing Code

2

Descriptor Code

4