|
Function To specify characteristics for
one or more RJE workstations.
This command can be used to add
BSC and SNA RJE workstations.
Not all parameters are applicable
to each type of workstation. The parameter descriptions indicate applicability
to each type and differences as appropriate. Parameters applicable
to BSC-only and SNA-only workstations are listed here.
Parameters
applicable to BSC RJE workstations only: - BLOCK=
- BUFEXPAN=
- HTABS=
- MFORM=
- MRF2780=
- MULTILV=
- RECFM=
- SHARABLE=
- TRANSPAR=
Parameters applicable to SNA RJE workstations only:
- Autolog=
- COMPACT=
- LUNAME=
- SETUP=
Most of the parameter specifications that can be changed
on this command require that the RJE workstation be inactive. Issue
the $D ACTRMT(nnnnn) command to obtain status
of active RJE workstations before issuing the $T RMT(nnnnn) command.
Syntax
>>-$T--RMT--+-nnnnn--+---------------+-------------------+------>
| '- ---+-nnnnn-+-' |
| '-*-----' |
| .-,--------------------------------. |
| V | |
'-(------+-nnnnn-+--+---------------+---+--)-'
'-*-----' '- ---+-nnnnn-+-'
'-*-----'
>--+---------------------------------+-------------------------->
'-| Selection limiting keywords |-'
>--+---------------------------+-------------------------------><
'-| Modification keywords |-'
Modification keywords
|--+------------------------+--+----------------------+--------->
'-,--Autolog--=--+-No--+-' '-,--BLOCK--=--+-No--+-'
'-Yes-' '-Yes-'
>--+-----------------------+--+------------------------+-------->
'-,--BUFEXPAN--=--+-0-+-' '-,--BUFSIZE--=--bufsize-'
+-1-+
'-2-'
>--+------------------------+--+-------------------------+------>
'-,--COMPACT--=--+-No--+-' '-,--COMPRESS--=--+-No--+-'
'-Yes-' '-Yes-'
>--+------------------------+--+---------------------+---------->
'-,--CONDEST--=--condest-' '-,--CONS--=--+-No--+-'
'-Yes-'
>--+------------------------------+----------------------------->
'-,--DEVTYPE--=--+-AS/400----+-'
+-AS400-----+
+-LUTYPE1---+
+-M20-2-----+
+-M20-4-----+
+-M20-5-----+
+-M20-6-----+
+-S/3-------+
+-S/36------+
+-S/360-----+
+-S/370-----+
+-SYSTEM/3--+
+-SYSTEM/36-+
+-SYSTEM3---+
+-SYSTEM36--+
+-S360------+
+-S370------+
+-1130------+
+-2770------+
+-2780------+
+-2922------+
+-3740------+
+-3780------+
'-3781------'
>--+--------------------------+--+----------------------+------->
'-,--Discintv--=--discintv-' '-,--HTABS--=--+-No--+-'
'-Yes-'
>--+------------------+--+----------------------------+--------->
'-,--LINE--=--line-' '-,--LOCAL190--=--+-ACTION-+-'
'-INFO---'
>--+--------------------+--+----------------------+------------->
'-,--LOGON--=--logon-' '-,--LUNAME--=--luname-'
>--+--------------------+--+------------------------+----------->
'-,--MFORM--=--+-J-+-' '-,--MRF2780--=--+-No--+-'
+-M-+ '-Yes-'
'-T-'
>--+-----------------------+--+------------------------+-------->
'-,--MSGPRT--=--+-No--+-' '-,--MULTILV--=--+-No--+-'
'-Yes-' '-Yes-'
>--+----------------------+--+----------------------+----------->
'-,--NUMPRt--=--numprt-' '-,--NUMPUn--=--numpun-'
>--+----------------------+--+--------------------------+------->
'-,--NUMRDr--=--numrdr-' '-,--Password--=--password-'
>--+---------------------------+--+-----------------------+----->
'-,--RECFM--=--+-FIXED----+-' '-,--RMT150--=--+-No--+-'
'-VARIABLE-' '-Yes-'
>--+--------------------------+--+-----------------------+------>
'-,--Routecde--=--routecde-' '-,--SETUP--=--+-MSG--+-'
'-PDIR-'
>--+------------------------------+----------------------------->
'-,--+-SHARable--+--=--+-No--+-'
'-SHAREable-' '-Yes-'
>--+-------------------------+--+------------------------+------|
'-,--TRANSPAR--=--+-No--+-' '-,--WAITIME--=--waitime-'
'-Yes-'
Selection limiting keywords
|--+------------------------------------+----------------------->
'-,----/----Autolog--+-=--+--+-No--+-'
'-^=-' '-Yes-'
>--+----------------------------------+------------------------->
'-,----/----BLOCK--+-=--+--+-No--+-'
'-^=-' '-Yes-'
>--+------------------------------------+----------------------->
'-,----/----COMPACT--+-=--+--+-No--+-'
'-^=-' '-Yes-'
>--+-------------------------------------+----------------------|
'-,----/----COMPRESS--+-=--+--+-No--+-'
'-^=-' '-Yes-'
|--+------------------------------------+----------------------->
'-,----/----CONDEST--+-=--+--condest-'
+-^=-+
+->--+
'-<--'
>--+---------------------------------+-------------------------->
'-,----/----CONS--+-=--+--+-No--+-'
'-^=-' '-Yes-'
>--+------------------------------------------+----------------->
'-,----/----DEVTYPE--+-=--+--+-AS/400----+-'
'-^=-' +-AS400-----+
+-LUTYPE1---+
+-M20-2-----+
+-M20-4-----+
+-M20-5-----+
+-M20-6-----+
+-S/3-------+
+-S/36------+
+-S/360-----+
+-S/370-----+
+-SYSTEM/3--+
+-SYSTEM/36-+
+-SYSTEM3---+
+-SYSTEM36--+
+-S360------+
+-S370------+
+-1130------+
+-2770------+
+-2780------+
+-2922------+
+-3740------+
+-3780------+
'-3781------'
>--+----------------------------------+------------------------->
'-,----/----HTABS--+-=--+--+-No--+-'
'-^=-' '-Yes-'
>--+------------------------------+----------------------------->
'-,----/----LINE--+-=--+--line-'
+-^=-+
+->--+
'-<--'
>--+----------------------------------------+------------------->
'-,----/----LOCAL190--+-=--+--+-ACTION-+-'
'-^=-' '-INFO---'
>--+--------------------------------+--------------------------->
'-,----/----LOGON--+-=--+--logon-'
+-^=-+
+->--+
'-<--'
>--+----------------------------------+------------------------->
'-,----/----LUNAME--+-=--+--luname-'
+-^=-+
+->--+
'-<--'
>--+--------------------------------+--------------------------->
'-,----/----MFORM--+-=--+--+-J-+-'
'-^=-' +-M-+
'-T-'
>--+------------------------------------+----------------------->
'-,----/----MRF2780--+-=--+--+-No--+-'
'-^=-' '-Yes-'
>--+-----------------------------------+------------------------>
'-,----/----MSGPRT--+-=--+--+-No--+-'
'-^=-' '-Yes-'
>--+------------------------------------+----------------------->
'-,----/----MULTILV--+-=--+--+-No--+-'
'-^=-' '-Yes-'
>--+----------------------------------+------------------------->
'-,----/----NUMPRt--+-=--+--numprt-'
+-^=-+
+->--+
'-<--'
>--+----------------------------------+------------------------->
'-,----/----NUMPUn--+-=--+--numpun-'
+-^=-+
+->--+
'-<--'
>--+----------------------------------+------------------------->
'-,----/----NUMRDr--+-=--+--numrdr-'
+-^=-+
+->--+
'-<--'
>--+---------------------------------------+-------------------->
'-,----/----RECFM--+-=--+--+-FIXED----+-'
'-^=-' '-VARIABLE-'
>--+-----------------------------------+------------------------>
'-,----/----RMT150--+-=--+--+-No--+-'
'-^=-' '-Yes-'
>--+--------------------------------------+--------------------->
'-,----/----Routecde--+-=--+--routecde-'
+-^=-+
+->--+
'-<--'
>--+-----------------------------------+------------------------>
'-,----/----SETUP--+-=--+--+-MSG--+-'
'-^=-' '-PDIR-'
>--+------------------------------------------+----------------->
'-,--+---/----SHARable--+--+-=--+--+-No--+-'
'---/----SHAREable-' '-^=-' '-Yes-'
>--+-------------------------------------+---------------------->
'-,----/----TRANSPAR--+-=--+--+-No--+-'
'-^=-' '-Yes-'
>--+------------------------------------+-----------------------|
'-,----/----WAITIME--+-=--+--waitime-'
+-^=-+
+->--+
'-<--'
Parameters - nnnnn
- The
subscript defining the RJE workstations affected by this command.
The subscript may specify a 1- to 5-digit RJE
workstation identifier or a range of identifiers as defined by an RMT(nnnnn) initialization statement. For information
about specifying a range for this subscript, see Command syntax conventions.
- Autolog={No|Yes}
- For
SNA RJE workstations only, specifies whether the SNA RJE workstation
can be automatically connected (logged on) when output (print/punch)
or messages are queued for transmission to the RJE workstation. The
RJE workstation is allowed to log on only if:
- This command also specifies a logical unit name through the LUNAME=
parameter on the corresponding RMTnn initialization statement.
- A JES2 line has been started and is available.
- The maximum number of sessions specified at initialization (with
the SESSIONS parameter on the TPDEF statement) has not been exceeded.
- BLOCK={No|Yes}
- For
BSC RJE workstations only, specifies whether this workstation
has a blocked (YES) or unblocked (NO) data record format.
Note: You
can change the value of this parameter only when the RJE workstation
is inactive.
- BUFEXPAN= {0|1|2}
- For
BSC 2770 RJE workstations only specifies whether this 2770 terminal
has a buffer-expansion feature.
- 0
- This terminal does not have the buffer-expansion feature.
- 1
- This terminal has the buffer-expansion feature and implies an
RJE workstation buffer of 264 bytes.
- 2
- This terminal has the additional buffer-expansion feature and
implies an RJE workstation buffer of 520 bytes.
Note: - You can change the value of this parameter only when the RJE workstation
is inactive.
- If an attached printer has a PRWIDTH= parameter greater than 120
bytes, specify BUFEXPAN=1 or 2.
- BUFSIZE=bufsize
- For
BSC RJE workstations, specifies the largest buffer (127 to the
BELOWBUF=(SIZE=) parameter value on the TPDEF initialization statement)
that can be either sent from or received by this workstation.
BUFSIZE=
enforces minimum buffer size specification based on device type for
BSC RJE workstations.
For SNA RJE workstations, specifies
the largest buffer (256 to the EXTBUF=(SIZE=) parameter value on the
TPDEF initialization statement) that can be either sent from or received
by this SNA RJE workstation.
The following table provides
the minimum buffer size requirements for various RJE workstation types.
If you specify a value less than that listed here, JES2 increases
BUFSIZE= to this minimum value. Table 1. JES2
BUFSIZE Minimum Buffer Size Requirements for RJE WorkstationsWorkstation |
Type |
BUFSIZE Value |
---|
SNA |
N/A |
256 |
Multileaving
Terminals
and Systems
|
N/A |
MBUFSIZE= value
on TPDEF statement
|
Hardware Terminal |
2770 without
buffer expansion
(BUFEXPAN=0)
|
127 |
Hardware Terminal |
2770 with
buffer expansion
(BUFEXPAN=1)
|
264 |
Hardware Terminal |
2770 with additional
buffer expansion
(BUFEXPAN=2)
|
520 |
Hardware Terminal |
2780 |
400 |
Hardware Terminal |
3780 |
520 |
Hardware Terminal |
3781 |
520 |
Note: You can change the value of this parameter only
when the RJE workstation is inactive.
- COMPACT={No|Yes}
- For
SNA RJE workstations only, specifies whether (YES) or not (NO)
this RJE workstation or terminal allows JES2 to send a compaction
table for use with a printer or punch data set.
Use the COMPACT
initialization statement to define compaction tables. If more than
one session is active and COMPACT=YES, all sessions are eligible to
receive a compaction table.
Note: You can change the value of
this parameter only when the RJE workstation is inactive.
- COMPRESS={No|Yes}
- Specifies
whether (YES) or not (NO) this RJE workstation uses the compression/expansion
feature.
For BSC RJE (2770 and 3780) workstations, if COMPRESS=YES
is specified on both the LINE(nn) initialization statement and the
remote device (print, punch, and reader) initialization statement
(R(nn).XXm), the COMPRESS= parameter on this command determines whether
JES2 uses the compression/expansion feature. If you specify COMPRESS=YES,
JES2 forces HTABS=NO.
If COMPRESS=NO on the LINE(nn) statement,
JES2 ignores this parameter.
For SNA RJE workstations,
if COMPACT=YES is specified, JES2 forces compression.
Note: You
can change the value of this parameter only when the RJE workstation
is inactive.
- CONDEST=condest
- The
route code (1 to the value of RMTNUM= on the TPDEF initialization
statement) that is used for responses to commands entered from this
RJE workstation. The value specified should be the number of a defined
RJE workstation.
- CONS={No|Yes}
- Specifies
whether (YES) or not (NO) this RJE workstation has an operator console
or is simulating an operator console through the &PRTCONS RMT
generation statement.
For SNA RJE workstations, you should
specify this parameter only if the RJE workstation has an operator
console.
If JES2 determines that this RJE workstation cannot
have a console, it forces CONS=NO.
Note: You can change the value
of this parameter only when the RJE workstation is inactive.
- DEVTYPE={type}
- Specifies the type of processor at this RJE workstation.
The
following types apply: - LUTYPE1
- For SNA RJE workstations, specifies that the workstation
can be accessed only through a logical line. If DEVTYPE= is changed
to a valid value other than LUTYPE1, this SNA remote workstation will
be changed to a BSC remote workstations.
- 2770|2780|3780|3781
- For BSC RJE workstations, specifies a hardware terminal.
- 2922|M20-2|M20-4|M20-5|M20-6
- For BSC RJE workstations, specifies a multileaving workstation.
- AS/400®|S/36|S/360|S/370|S/3
- For BSC RJE workstations, specifies a system.
Note: - If you define a workstation that is not explicitly supported by
JES2 but does emulate one of the types listed above, consult the documentation
for that terminal so you set characteristics (such as buffer sizes)
appropriately.
- To ensure that punch output is directed to the proper device,
specify ‘3781' to define remote 3780 terminals that contain punches.
- You can change the value of this parameter only when the RJE workstation
is inactive.
- Changing this parameter to a different type (particularly between
BSC and SNA types) causes certain restrictions on other parameters
(such as BUFSIZE=). Review carefully all parameters to ensure that
this command is valid. For further information concerning parameter
requirements for the RMT(nn) statement, refer to z/OS JES2 Initialization and Tuning Reference, SA32-0992.
- Discintv=discintv
- For
BSC RJE workstations, specifies the time interval in seconds (0
to 8160) after which, if there has been no successful text transmission
in either direction, JES2 disconnects this RJE workstation from the
processing unit.
For SNA RJE workstations, specifies the maximum interval
in seconds (0 to 8160) after which, if there has been no successful
text transmission in either direction, JES2 ends the session between
the SNA RJE workstation and the processing unit. - JES2 rounds this value to the next highest multiple of 32.
- 0 indicates that this terminal is not to be disconnected
- Error recovery tries and idle time do not count as successful
text transmission.
- If automatic disconnect is not specified, the remote terminal
remains connected until the operator signs it off.
- HTABS={No|Yes}
- For
BSC RJE workstations only, specifies whether (YES) or not (NO)
this 2770 or 2780 terminal has the horizontal format-control feature.
If you specify COMPRESS=YES, this parameter is forced to HTABS=NO.
Note: You
can change the value of this parameter only when the RJE workstation
is inactive.
- LINE=line
- Specifies
the number (0-65535) of the teleprocessing (BSC) or logical (SNA)
line that are both connected and dedicated to this terminal.
For BSC RJE workstations, if you specify LINE=0, JES2 provides
a nondedicated RJE workstation, which can use any nondedicated BSC
line that requires a /*SIGNON JCL statement to start.
For
SNA RJE workstations, if you specify LINE=0, JES2 provides a nondedicated RJE
workstation, which can use any nondedicated SNA line. If you
specify LINE= as a value other than 0, you must also specify the UNIT=SNA
parameter on the LINE(nn) initialization statement.
Note: You
can change the value of this parameter only when the RJE workstation
is inactive.
- LOCAL190={ACTION|INFO}
- Specifies
the type of operator setup messages ($HASP190) that JES2 issues at
the local processor console for this RJE workstation. If you do not
specify this parameter, JES2 provides a default of ACTION.
- ACTION
- Specifies that operator setup messages issued at the local console
for this remote device are action messages (messages that require
an operator action to delete them from the console).
- INFO
- Specifies operator setup messages issued at the local console
for this remote device as information messages (messages that
do not require an operator action to delete them from the console).
- LOGON=logon
- Specifies
the number (1-999) of the local LOGON DCT which should be used when
specifying connections to the application. The default value of 0
indicates that the LOGON DCT defined with the lowest number is to
be used.
- LUNAME=luname
- For
SNA RJE workstations only, specifies the logical unit name of
this RJE workstation or terminal. If you specify this parameter,
it must match the name defined to VTAM® at
system initialization in SYS1.VTAMLST.
If you use the automatic
logon capability (Autolog=YES), you must specify an LUNAME= value.
If the logical unit associated with the logical unit name is not
the first of the terminal's logical units to logon to JES2, the LUNAME
associated with the session comes from the name pointed to by the
parameter list that VTAM passes to the JES2 logon exit.
Note: You
can change the value of this parameter only when the RJE workstation
is inactive.
- MFORM={J|M|T}
- For
BSC RJE workstations only, specifies the amount of information
to be displayed in JES2 remote console messages for this RJE workstation.
- J
- JES2 job-related messages including the jobname and job ID of
the issuer.
- M
- JES2 job-related message text only.
- T
- JES2 job-related messages including a time stamp, the jobname,
and job ID of the issuer.
- MRF2780={No|Yes}
- For
BSC RJE workstations only, specifies whether (YES) or not (NO)
this 2780 terminal has the multiple-record feature.
Note: You can
change the value of this parameter only when the RJE workstation is
inactive.
- MSGPRT={No|Yes}
- For
BSC remotes, specifies whether (YES) or not (NO) JES2 prints messages
routed to a printer attached to the console of an RJE workstation.
- NO
- Specifies that JES2 discards messages if the RJE workstation console
is not available.
Specify NO if you would rather discard messages
instead of printing them on the first available printer at the remote.
For
BSC RJE workstations, this parameter only has meaning for an RJE
workstation that does not have a console.
- YES
- Specifies that JES2 prints messages if the remote console is unavailable.
For example, the remote console might not exist, be signed on, or
have enough messages queued to it to exceed the RMTMSG= parameter
on the TPDEF initialization statement.
For BSC RJE workstations,
note that once a message is spooled for an RJE workstation, that message
can only be printed; it cannot be displayed on an RJE workstation
console.
- MULTILV={No|Yes}
- For
BSC RJE workstations only, specifies whether (YES) or not (NO)
this RJE workstation uses the BSC multileaving interfaces. If MULTILV=YES,
you must specify a multileaving workstation. MULTILV=NO defines this
RJE workstation as a BSC hardware terminal.
Note: You can change
the value of this parameter only when the RJE workstation is inactive.
- NUMPRt=numprt
- Specifies
the number (0-7) of printers (BSC) or logical printers (SNA) at this
RJE workstation. JES2 provides the defaults specified on the R(nn).PR(m)
initialization statement for new printers if NUMPRT= is increased.
Use the $T R(nn).PR(m) command to change any characteristics of
each printer.
For BSC RJE workstations, JES2 can use
values greater than 1 only when you specify MULTILV=YES. If you specify
MULTILV=NO, JES2 uses a value of NUMPRT=1. A maximum total of eight
printers and punches can be defined.
Note: If you specify this
parameter as 0, JES2 resets it to 1.
For SNA RJE workstations,
a maximum total of eight printers, punches, and a console can be specified.
The maximum value for NUMPRT= is 6 if you also specify CONS=YES.
Specify
NUMPRT=0 if you want no printers on this SNA RJE workstation. Note: - You can change the value of this parameter only when the RJE workstation
is inactive.
- You must specify at least one device (printer, punch, reader,
or SNA console) on the RMT definition.
- NUMPUn=numpun
- Specifies
the number (0-7) of card punches (BSC) or logical card punches (SNA)
at this RJE workstation or terminal. You must specify at least one
device (printer, punch, reader, or SNA console) on the remote definition.
JES2 provides the defaults specified on the R(nn).PU(m) initialization
statement for new punches if NUMPUN= is increased. Then you can use
the $T R(nn).PU(m) command to change any characteristics of each punch.
For BSC RJE workstations, a maximum total of eight printers
and punches can be defined. If you specify MULTILV=NO and this parameter
is specified greater than 1, JES2 uses only 1.
For SNA
RJE workstations, a maximum total of eight printers, punches,
and a console can be defined. SNA RJE workstations can support as
many as seven punch data streams.
Note: You can change the value
of this parameter only when the RJE workstation is inactive.
- NUMRDr=numrdr
- Specifies
the number (0-7) of card readers (BSC) or logical card readers (SNA)
at this RJE workstation or terminal. SNA RJE workstations can support
as many as seven reader data streams. You must specify at least one
device (printer, punch, reader, or SNA console) on the remote definition.
JES2 provides the defaults specified on the R(nn).RD(m) initialization
statement for new readers if NUMRDR= is increased. Then you can use
the $T R(nn).RD(m) command to change any characteristics of each reader.
For BSC workstations, if you specify MULTILV=NO, this parameter
is set to 1. If you set this parameter to 0, JES2 resets it to 1.
Note: You
can change the value of this parameter only when the RJE workstation
is inactive.
- Password=password
- The
1- to 8-character security password used to prevent unauthorized RJE
workstation users from using the resources of this RJE workstation.
If you do not specify this parameter, JES2 provides no password.
If you specify a null password (P=), JES2 deletes the previously assigned
password.
Note: Be certain to make a note of those passwords
assigned because there is no facility for displaying the passwords
in effect.
- RECFM={FIXED|VARIABLE}
- For
BSC RJE workstations only, specifies whether the data record for
this terminal is fixed-length (FIXED) or variable-length (VARIABLE).
Note: You can change the value of this parameter only when the RJE
workstation is inactive.
- RMT150={No|Yes}
- Specifies
$HASP150 message routing as follows:
- No
- The $HASP150 message is sent only to the local operator.
- Yes
- If this RJE workstation has a console, the $HASP150 message is
first sent to this console and then to the local operator.
Note: - For SYSTEM36 (S/36) terminals, if you specify CONS=YES, MULTILV=YES,
and RMT150=YES, the remote printer pauses to ensure that the $HASP150
message arrives at the console before the data sets begin to print.
- For SNA RJE workstations, this parameter is valid only if CONS=YES.
- This parameter is not valid for hardware terminals.
- Routecde=routecde
- Specifies
the route code (1 to 32767) assigned to this terminal and its associated
printers, punches and readers. (However, you can specify one route
code for the RJE workstation and different ones for the printers and
punches to meet unique installation requirements.) If you do not assign
a Routecde= value, JES2 assigns the number of this terminal (RMT(nn))
as its route code.
Note: - You can change the value of this parameter only when the RJE workstation
is inactive.
- If you are changing the value of this parameter to a value not
equivalent to nn of RMT(nn), you must first complete
the following steps:
- Change the routing for all work from the previous RJE workstation
routing to the new RJE workstation routing.
- Determine if you need to change the Routecde= parameter for this
RJE workstation's associated remote devices (printers, punches, readers,
or console).
- SETUP={MSG|PDIR}
- For
SNA RJE workstations only, specifies setup information as follows:
- MSG
- Specifies that JES2 must inform the remote operator of any setup
requirements through the $HASP190 message. After setup is complete,
the operator must enter a $S command to start JES2 transmission.
- PDIR
- Specifies that JES2 constructs and sends a peripheral data information
record (PDIR) to the RJE workstation. The RJE workstation must process
the data set header and generate any required messages. This setting
allows spooling of data and generation of multiple copies of a data
set at the RJE workstation.
Note: You can change the value of this parameter
only when the RJE workstation is inactive.
- SHARable|SHAREable={No|YES}
- For
BSC RJE workstations only, specifies whether (YES) or not (NO)
JES2 allows the LINE= parameter value to be used by other RJE workstations.
(If LINE=0, JES2 ignores this parameter.)
- NO
- Indicates that no other RJE workstations can specify and use the
LINE= value and no /*SIGNON JCL statement is needed to start the remote.
- YES
- Indicates that multiple RMT definitions can also specify and use
(share) the line specified on LINE= and a /*SIGNON JCL statement is
required to start one of these RJE workstations.
Note: - You can change the value of this parameter only when the RJE workstation
is inactive.
- If you change the LINE= parameter specification and you do not
specify this parameter, JES2 sets this parameter to SHARABLE=YES.
- TRANSPAR={No|Yes}
- For
BSC RJE workstations only, specifies whether (YES) or not (NO)
this RJE workstation has the text-transparency feature. To use this
feature, you must also specify TRANSPAR=YES on the LINE(nn) initialization
statement.
Note: You can change the value of this parameter only
when the RJE workstation is inactive.
- WAITIME=waitime
- The
length of time in seconds (0-30), that the RJE workstation access
method (RTAM) should wait after completing the processing of any input
stream, printed output stream, or punched output stream to allow the
operator to enter an input stream at this RJE workstation.
For
SNA RJE workstations, if WAITIME= is set too low (note the default
of 1 second), contention might occur during SNA logon processing,
which results in $HASP094 messages and the termination of the SNA
session. Increase this parameter to allow the RJE workstation adequate
time to respond during logon processing so that proper LU type 1 protocol
is followed.
Authority Required This command requires device authority.
The description of the $T RDRnn command explains how to ensure that
the authority of the appropriate MVS™ system
command group is assigned.
This command requires update security
access authority. For a description of assigning command input authority,
see z/OS JES2 Initialization and Tuning Guide, SA32-0991.
Scope Single member. The values
supplied for this command will be in effect for this member only.
Depending
on your installation's setup, however, you might want this command
to be applied to all members of the MAS (to ensure a consistent environment
across the MAS). If so, you can use the MVS ROUTE
*ALL command to issue this command to all active members (if the JES2
command character is the same on all members). See z/OS MVS System Commands, SA38-0666 for
more information on using the ROUTE *ALL command.
Messages The $HASP879 message displays
the status of the specified remote device and its current characteristics.
Examples 1 $trmt1,d=8000,password=newpas,msgprt=n
$HASP879 RMT(1) DEVTYPE=S/360,STATUS=INACTIVE,BUFSIZE=400,
$HASP879 CONDEST=1,CONS=YES,DISCINTV=8000,LINE=0,
$HASP879 LOCAL190=ACTION,MFORM=T,MSGPRT=NO,MULTILV=YES,
$HASP879 NUMPRT=2,NUMPUN=1,NUMRDR=1,PASSWORD=(SET),
$HASP879 RMT150=NO,ROUTECDE=1,TRANSPAR=NO,WAITIME=1
JES2 sets RJE workstation 1 to automatic connect/disconnect
mode. If no session activity takes place for 8000 consecutive seconds,
JES2 automatically disconnects the RJE workstation. The password (NEWPAS)
does not appear in the $HASP879 message. MSGPRT=NO specifies that
JES2 is to discard remote console messages spooled for later display
at a remote printer. 2 $t rmt141,local190=action,mform=m,waitime=15
$HASP879 RMT(141) DEVTYPE=S/360,STATUS=INACTIVE,BUFSIZE=400,
$HASP879 CONDEST=1,CONS=YES,DISCINTV=8000,LINE=0,
$HASP879 LOCAL190=ACTION,MFORM=M,MSGPRT=NO,MULTILV=YES,
$HASP879 NUMPRT=2,NUMPUN=1,NUMRDR=1,PASSWORD=(SET),
$HASP879 RMT150=NO,ROUTECDE=1,TRANSPAR=NO,WAITIME=15
The results of this command are: - JES2 displays only the message text when job related messages
are sent to BSC RJE workstation 141.
- The operator setup messages issued at the local console for this
remote device are flagged as action messages (messages that require
an operator action to delete them from the console).
- RTAM waits 15 seconds after completing the processing of any input
stream or output stream, to allow the operator to enter an input stream
at this RJE workstation.
3 $t rmt6,luname=lu3770pc
$HASP879 RMT(6) DEVTYPE=LUTYPE1,STATUS=INACTIVE,AUTOLOG=NO,
$HASP879 BUFSIZE=256,COMPACT=NO,COMPRESS=YES,CONDEST=6,
$HASP879 CONS=NO,DISCINTV=0,LINE=0,LOCAL190=ACTION,
$HASP879 LUNAME=LU3770PC,MFORM=T,MSGPRT=YES,NUMPRT=1,
$HASP879 NUMPUN=0,NUMRDR=1,PASSWORD=(NOTSET),RMT150=NO,
$HASP879 ROUTECDE=6,SETUP=MSG,START=NO,WAITIME=1
JES2 sets the logical unit name of SNA RJE workstation
6 to ‘lu3770pc'.
|