Function To add one or more RJE workstations.
You cannot use this command to add an RJE workstation with a number
higher than that either previously defined by RMTNUM= on the TPDEF
initialization statement or the highest numbered RJE workstation defined by RMT(nnnnn) initialization
statements.
This command can be used to add BSC and SNA RJE
workstations.
Not all parameters are applicable to each type
of workstation. The parameter descriptions indicate applicability
to each type and differences as appropriate. Parameters applicable
to BSC-only and SNA-only workstations are listed here.
Parameters
applicable to BSC RJE workstations only: - BLOCK=
- BUFEXPAN=
- HTABS=
- MFORM=
- MRF2780=
- MULTILV=
- RECFM=
- SHARABLE=
- TRANSPAR=
Parameters applicable to SNA RJE workstations only:
- Autolog=
- COMPACT=
- LUNAME=
- SETUP=
Syntax
>>-$ADD--RMT--+-nnnnn--+---------------+-------------------+---->
| '- ---+-nnnnn-+-' |
| '-*-----' |
| .-,--------------------------------. |
| V | |
'-(------+-nnnnn-+--+---------------+---+--)-'
'-*-----' '- ---+-nnnnn-+-'
'-*-----'
>--+------------------------+--+----------------------+--------->
'-,--Autolog--=--+-No--+-' '-,--BLOCK--=--+-No--+-'
'-Yes-' '-Yes-'
>--+-----------------------+--+------------------------+-------->
'-,--BUFEXPAN--=--+-0-+-' '-,--BUFSIZE--=--bufsize-'
+-1-+
'-2-'
>--+------------------------+--+-------------------------+------>
'-,--COMPACT--=--+-No--+-' '-,--COMPRESS--=--+-No--+-'
'-Yes-' '-Yes-'
>--+------------------------+--+---------------------+---------->
'-,--CONDEST--=--condest-' '-,--CONS--=--+-No--+-'
'-Yes-'
>--+------------------------------+----------------------------->
'-,--DEVTYPE--=--+-AS/400----+-'
+-AS400-----+
+-LUTYPE1---+
+-M20-2-----+
+-M20-4-----+
+-M20-5-----+
+-M20-6-----+
+-S/3-------+
+-S/36------+
+-S/360-----+
+-S/370-----+
+-SYSTEM/3--+
+-SYSTEM/36-+
+-SYSTEM3---+
+-SYSTEM36--+
+-S360------+
+-S370------+
+-1130------+
+-2770------+
+-2780------+
+-2922------+
+-3740------+
+-3780------+
'-3781------'
>--+--------------------------+--+----------------------+------->
'-,--Discintv--=--discintv-' '-,--HTABS--=--+-No--+-'
'-Yes-'
>--+------------------+--+----------------------------+--------->
'-,--LINE--=--line-' '-,--LOCAL190--=--+-ACTION-+-'
'-INFO---'
>--+--------------------+--+----------------------+------------->
'-,--LOGON--=--logon-' '-,--LUNAME--=--luname-'
>--+--------------------+--+------------------------+----------->
'-,--MFORM--=--+-J-+-' '-,--MRF2780--=--+-No--+-'
+-M-+ '-Yes-'
'-T-'
>--+-----------------------+--+------------------------+-------->
'-,--MSGPRT--=--+-No--+-' '-,--MULTILV--=--+-No--+-'
'-Yes-' '-Yes-'
>--+----------------------+--+----------------------+----------->
'-,--NUMPRt--=--numprt-' '-,--NUMPUn--=--numpun-'
>--+----------------------+--+--------------------------+------->
'-,--NUMRDr--=--numrdr-' '-,--Password--=--password-'
>--+---------------------------+--+-----------------------+----->
'-,--RECFM--=--+-FIXED----+-' '-,--RMT150--=--+-No--+-'
'-VARIABLE-' '-Yes-'
>--+--------------------------+--+-----------------------+------>
'-,--Routecde--=--routecde-' '-,--SETUP--=--+-MSG--+-'
'-PDIR-'
>--+------------------------------+----------------------------->
'-,--+-SHARable--+--=--+-No--+-'
'-SHAREable-' '-Yes-'
>--+-------------------------+--+------------------------+-----><
'-,--TRANSPAR--=--+-No--+-' '-,--WAITIME--=--waitime-'
'-Yes-'
Parameters - (nnnnn)
- The subscript defining the RJE workstations affected by this command.
The subscript may specify a 1- to 5-digit RJE
workstation identifier or a range of identifiers as defined by an RMT(nnnnn) initialization statement. For information
about specifying a range for this subscript, see Command syntax conventions.
- Autolog={No|Yes}
- For SNA RJE workstations only, specifies whether the SNA
RJE workstation can be automatically connected (logged on) when output
(print/punch) or messages are queued for transmission to the RJE workstation.
The RJE workstation is allowed to log on only if:
- This command also specifies a logical unit name through the LUNAME=
parameter on the corresponding RMTnnnn initialization statement.
- A JES2 line has been started and is available.
- The maximum number of sessions specified at initialization (with
the SESSIONS parameter on the TPDEF statement) has not been exceeded.
- BLOCK={No|Yes}
- For BSC RJE workstations only, specifies whether this workstation
has a blocked (YES) or unblocked (NO) data record format.
- BUFEXPAN= {0|1|2}
- For BSC 2770 RJE workstations only, specifies whether this
2770 terminal has a buffer-expansion feature. If you do not specify
a value, JES2 provides no buffer expansion.
- 0
- This terminal does not have the buffer-expansion feature.
- 1
- This terminal has the buffer-expansion feature and implies an
RJE workstation buffer of 264 bytes.
- 2
- This terminal has the additional buffer-expansion feature and
implies an RJE workstation buffer of 520 bytes.
Note: If an attached printer has a PRWIDTH= parameter
greater than 120 bytes, specify BUFEXPAN=1 or 2.
- BUFSIZE=bufsize
- For BSC RJE workstations, specifies the largest buffer
(127 to the BELOWBUF=(SIZE=) parameter value on the TPDEF initialization
statement) that can be either sent from or received by this workstation.
BUFSIZE= enforces minimum buffer size specification based on device
type for BSC RJE workstations.
For SNA RJE workstations,
specifies the largest buffer (256 to the EXTBUF=(SIZE=) parameter
value on the TPDEF initialization statement) that can be either sent
from or received by this SNA RJE workstation.
If you do not
specify this parameter, JES2 provides the following defaults for the
following device types: Table 1. JES2
BUFSIZE Defaults for RJE WorkstationsWorkstation |
Type |
BUFSIZE Value |
---|
SNA |
N/A |
256 |
Multileaving Terminals
and Systems
|
N/A |
MBUFSIZE= value on TPDEF statement
|
Hardware Terminal |
2770 without
buffer expansion
(BUFEXPAN=0)
|
127 |
Hardware Terminal |
2770 with
buffer expansion
(BUFEXPAN=1)
|
264 |
Hardware Terminal |
2770 with additional
buffer expansion
(BUFEXPAN=2)
|
520 |
Hardware Terminal |
2780 |
400 |
Hardware Terminal |
3780 |
520 |
Hardware Terminal |
3781 |
520 |
- COMPACT={No|Yes}
- For SNA RJE workstations only, specifies whether (YES)
or not (NO) this RJE workstation or terminal allows JES2 to send a
compaction table for use with a printer or punch data set.
Use
the COMPACT initialization statement to define compaction tables.
If more than one session is active and COMPACT=YES, all sessions are
eligible to receive a compaction table.
- COMPRESS={No|Yes}
- Specifies whether (YES) or not (NO) this RJE workstation uses
the compression/expansion feature.
For BSC RJE (2770 and 3780)
workstations, specifies if COMPRESS=YES is specified on both the
LINE(nnnn) initialization statement and the remote device (print,
punch, and reader) initialization statement (R(nnnn).XXm), the COMPRESS=
parameter on this command determines whether JES2 uses the compression/expansion
feature. If you specify COMPRESS=YES, JES2 forces HTABS=NO.
If
COMPRESS=NO on the LINE(nnnn) statement, JES2 ignores this parameter.
For
SNA RJE workstations, if COMPACT=YES is specified, JES2 forces
compression.
- CONDEST=condest
- The route code (1 to the value of RMTNUM= on the TPDEF initialization
statement) that is used for responses to commands entered from this
RJE workstation. The value specified should be the number of a defined
RJE workstation.
- CONS={No|Yes}
- Specifies whether (YES) or not (NO) this RJE workstation has an
operator console or is simulating an operator console through the &PRTCONS
RMT generation statement. For SNA RJE workstations, you should
specify this parameter only if the RJE workstation has an operator
console.
If JES2 determines that this remote workstation cannot
have a console, it forces CONS=NO.
If you do not specify this
parameter, JES2 provides a default of CONS=NO. The CONS=NO value does
not stop JES2 from sending data destined to a console.
- DEVTYPE=type
- Specifies the type of processor at this RJE workstation. If this
parameter is not specified, terminal type 2770 (BSC workstation) is
used.
The following types apply: - LUTYPE1
- For SNA RJE workstations, specifies that the workstation
can be accessed only through a logical line. (This is the only valid
SNA specification for DEVTYPE=.)
- 2770|2780|3740|3780|3781
- For BSC RJE workstations, specifies a hardware terminal.
- 1130|2922|M20-2|M20-4|M20-5|M20-6
- For BSC RJE workstations, specifies a multileaving workstation.
- AS400|AS/400®|SYSTEM36|SYSTEM/36| S/36|S360|S/360|S370|S/370|SYSTEM3|SYSTEM/3|S/3
- For BSC RJE workstations, specify a system.
Note: - If you define a workstation that is not explicitly supported by
JES2 but does emulate one of the types listed above, consult the documentation
for that terminal so you set characteristics (such as buffer sizes)
appropriately.
- Specify a 3740 hardware terminal as a 2780.
- To ensure that punch output is directed to the proper device,
specify ‘3781' to define remote 3780 terminals that contain punches.
- Discintv=discintv
- For BSC RJE workstations, specifies the time interval in
seconds (0 to 8160) after which, if there has been no successful text
transmission in either direction, JES2 disconnects this RJE workstation
from the processing unit.
For SNA RJE workstations, specifies
the maximum interval in seconds (0 to 8160) after which, if
there has been no successful text transmission in either direction,
JES2 ends the session between the SNA RJE workstation and the processing
unit. - JES2 rounds this value to the next highest multiple of 32.
- 0 indicates that this terminal is not to be disconnected
- Error recovery tries and idle time do not count as successful
text transmission.
- If automatic disconnect is not specified, the remote terminal
remains connected until the operator signs it off.
- HTABS={No|Yes}
- For BSC RJE workstations only, specifies whether (YES)
or not (NO) this 2770 or 2780 terminal has the horizontal format-control
feature.
If you specify COMPRESS=YES, this parameter is forced
to HTABS=NO.
- LINE=line
- Specifies the number (0-65535) of the teleprocessing
(BSC) or logical (SNA) lines that are both connected and dedicated to
this terminal.
For BSC RJE workstations, if you specify
LINE=0, JES2 provides a nondedicated RJE workstation, which
can use any nondedicated BSC line. A /*SIGNON JCL statement
is required to start the RJE workstation.
For SNA RJE workstations,
if you specify LINE=0, JES2 provides a nondedicated RJE workstation,
which can use any nondedicated SNA line. If you specify LINE=
as a value other than 0, you must also specify the UNIT=SNA parameter
on the LINE(nnnn) initialization statement.
- LOCAL190={ACTION|INFO}
- Specifies the type of operator setup messages ($HASP190) that
JES2 issues at the local processor console for this RJE workstation.
If you do not specify this parameter, JES2 provides a default of ACTION.
- ACTION
- Specifies that operator setup messages issued at the local console
for this remote device are action messages (messages that require
an operator action to delete them from the console).
- INFO
- Specifies operator setup messages issued at the local console
for this remote device as information messages (messages that
do not require an operator action to delete them from the console).
- LOGON=logon
- Specifies the number (1-999) of the local LOGON DCT which should
be used when starting a JES2-initiated session with this SNA remote
(autologon or $S RMT). The default value of 0 indicates that LOGON2
is to be used unless it is not defined, in which case the lowest numbered
logon is to be used.
- LUNAME=luname
- For SNA RJE workstations only, specifies the logical unit
name of this RJE workstation or terminal. If you specify this parameter,
it must match the name defined to VTAM® at
system initialization.
If you use the automatic logon capability
(Autolog=YES), you must specify an LUNAME= value. If the logical
unit associated with the logical unit name is not the first of the
terminal's logical units to logon to JES2, the LUNAME associated with
the session comes from the name pointed to by the parameter list that VTAM passes
to the JES2 logon exit.
- MFORM={J|M|T}
- For BSC RJE workstations only, specifies the amount of
information to be displayed in JES2 remote console messages for this
RJE workstation.
- J
- JES2 job-related messages including the jobname and job ID of
the issuer.
- M
- JES2 job-related message text only.
- T
- JES2 job-related messages including a time stamp, the jobname,
and job ID of the issuer.
- MRF2780={No|Yes}
- For BSC RJE workstations only, specifies whether (YES)
or not (NO) this 2780 terminal has the multiple-record feature.
- MSGPRT={No|Yes}
- For BSC RJE workstations, specifies whether (YES) or not
(NO) JES2 prints messages routed to a printer attached to the console
of an RJE workstation.
- NO
- Specifies that JES2 discards messages if the RJE workstation console
is not available.
Specify NO if you would rather discard messages
instead of printing them on the first available printer at the remote.
For
BSC RJE workstations, this parameter only has meaning for an RJE
workstation that does not have a console.
- YES
- Specifies that JES2 prints messages if the remote console is unavailable.
For example, the remote console might not exist, be signed on, or
have enough messages queued to it to exceed the RMTMSG= parameter
on the TPDEF initialization statement.
For BSC RJE workstations,
note that once a message is spooled for an RJE workstation, that message
can only be printed; it cannot be displayed on an RJE workstation
console.
- MULTILV={No|Yes}
- For BSC RJE workstations only, specifies whether (YES)
or not (NO) this RJE workstation uses the BSC multileaving interfaces.
If MULTILV=YES, you must specify a multileaving workstation. MULTILV=NO
defines this RJE workstation as a BSC hardware terminal.
- NUMPRt=numprt
- Specifies the number (0-7) of printers (BSC) or logical printers
(SNA) at this RJE workstation or terminal. JES2 provides the defaults
specified on the R(nnnn).PR(m) initialization statement.
Use the
$T R(nnnn).PR(m) command to change any characteristics of each printer.
For
BSC RJE workstations, JES2 can use values greater than 1 only
when you specify MULTILV=YES. If you specify MULTILV=NO, JES2 uses
a value of NUMPRT=1. A maximum total of eight printers and punches
can be defined.
For SNA RJE workstations, a maximum
total of eight printers, punches, and a console can be specified.
You must specify at least one device on the RMT(nnnn) definition.
If
you do not specify a value, JES2 provides a default of NUMPRT=1. Specify
NUMPRT=0 if you want no printers on this RJE workstation or terminal.
- NUMPUn=numpun
- Specifies the number (0-7) of card punches (BSC) or logical card
punches (SNA) at this RJE workstation or terminal. You must specify
at least one device (printer, punch, or reader) on the remote definition.
JES2 provides the defaults specified on the R(nnnn).PU(m) initialization
statement. Then you can use the $T R(nnnn).PU(m) command to change
any characteristics of each punch.
For BSC RJE workstations,
a maximum total of eight printers and punches can be defined. If you
specify MULTILV=NO and this parameter is specified greater than 1,
JES2 uses only 1.
For SNA RJE workstations, a maximum
total of eight printers, punches, and a console can be defined. SNA
RJE workstations can support as many as seven reader data streams.
- NUMRDr=numrdr
- Specifies the number (0-7) of card readers (BSC) or logical card
readers (SNA) at this RJE workstation or terminal. SNA RJE workstations
can support as many as seven reader data streams. You must specify
at least one device (printer, punch, or reader) on the remote definition.
JES2 provides the defaults specified on the R(nnnn).RD(m) initialization
statement. Then you can use the $T R(nnnn).RD(m) command to change
any characteristics of each reader.
If you do not specify a value,
JES2 provides a default of NUMRDR=1.
- Password=password
- The 1 to 8 character security password used to prevent unauthorized
RJE workstation users from using the resources of this RJE workstation.
If you do not specify this parameter, JES2 provides no password.
Note: Be
certain to make a note of those passwords assigned because there is
no facility for displaying the passwords in effect.
- RECFM={FIXED|VARIABLE}
- For BSC RJE workstations only, specifies whether the data
record for this terminal is fixed-length (FIXED) or variable-length
(VARIABLE).
- RMT150={No|Yes}
- Specifies $HASP150 message routing as follows:
- Y
- If this RJE workstation has a console, the $HASP150 message is
first sent to this console and then to the local operator.
- N
- The $HASP150 message is sent only to the local operator.
Note: - For SYSTEM36 (S/36) terminals, if you specify CONS=YES, MULTILV=YES,
and RMT150=YES, the remote printer pauses to ensure that the $HASP150
message arrives at the console before the data sets begin to print.
- For SNA RJE workstations, this parameter is valid only if CONS=YES.
- This parameter is not valid for hardware terminals. Refer to the
DEVTYPE= parameter for a list of valid hardware terminal types for
SNA RJE workstations.
- Routecde=routecde
- Specifies the route code (1 to 32767) assigned to this terminal
and its associated printers, punches and readers. If you do not assign
a Routecde= value, JES2 assigns the number of this terminal (RMT(nnnn))
as its route code.
New output created can take advantage
of this route code immediately but existing output might require the
$R command to be selected by this destination.
- SETUP={MSG|PDIR}
- For SNA RJE workstations only, specifies setup information
as follows:
- MSG
- Specifies that JES2 must inform the remote operator of any setup
requirements through the $HASP190 message. After setup is complete,
the operator must enter a $S command to start JES2 transmission.
- PDIR
- Specifies that JES2 constructs and sends a peripheral data information
record (PDIR) to the RJE workstation. The RJE workstation must process
the data set header and generate any required messages. This setting
allows spooling of data and generation of multiple copies of a data
set at the RJE workstation.
- SHARable|SHAREable={No|Yes}
- For BSC RJE workstations only, specifies whether (YES)
or not (NO) JES2 allows the LINE= parameter value to be used by other
RJE workstations. (If LINE=0, JES2 ignores this parameter.)
- NO
- Indicates that no other RJE workstations can specify and use the
LINE= value and no /*SIGNON JCL statement is needed to start the remote.
- YES
- Indicates that multiple RMT definitions can also specify and use
(share) the line specified on LINE= and a /*SIGNON JCL statement is
required to start one of these RJE workstations.
- TRANSPAR={No|Yes}
- For BSC RJE workstations only, specifies whether (YES)
or not (NO) this RJE workstation has the text-transparency feature.
To use this feature, you must also specify TRANSPAR=YES on the LINE(nnnn)
initialization statement.
- WAITIME=waitime
- The length of time in seconds (0-30), that the RJE workstation
access method (RTAM) should wait after completing the processing of
any input stream, printed output stream, or punched output stream
to allow the operator to enter an input stream at this RJE workstation.
For SNA RJE workstations, if WAITIME= is set too low (note
the default of 1 second), contention might occur during SNA logon
processing, which results in $HASP094 messages and the termination
of the SNA session. Increase this parameter to allow the RJE workstation
adequate time to respond during logon processing so that proper LU
type 1 protocol is followed.
Authority Required This command requires device authority.
The description of the $T RDRnn command explains how to ensure that
the authority of the appropriate MVS™ system
command group is assigned.
This command requires control security
access authority. For a description of assigning command input authority,
see z/OS JES2 Initialization and Tuning Guide, SA32-0991.
Scope Single member. The values
supplied for this command will be in effect for this member only.
Messages The $HASP879 message displays
the status of the specified RJE workstation.
Examples 1 $addrmt83,devtype=2780,transpar=n
$HASP879 RMT(83) DEVTYPE=2780,STATUS=INACTIVE,BUFEXPAN=O,
BLOCK=YES,BUFSIZE=400,COMPRESS=NO,
CONDEST=83,DISCINTV=0,HTABS=NO,LINE=0
LOCAL190=ACTION,MFORM=T,MRF2780=NO,
MSGPRT=YES,MULTILV=NO,NUMPRT=1,NUMPUN=0,
NUMRDR=1,PASSWORD=(NOTSET),RECFM=VARIABLE,
RMT150=NO,ROUTECDE=83,TRANSPAR=NO,WAITIME=1
JES2 adds BSC RJE workstation 83 with a hardware terminal
that does not have the text transparency feature. 2 $addrmt11,devtype=lutype1,numpun=7,cons=n,numprt=1
$HASP879 RMT(11) DEVTYPE=LUTYPE1,STATUS=INACTIVE,AUTOLOG=NO,
BUFSIZE=256,COMPACT=NO,COMPRESS=NO,
CONDEST=11,CONS=NO,DISCINTV=0,LINE=0,
LOCAL190=ACTION,LUNAME=,MFORM=T,MSGPRT=YES,
NUMPRT=1,NUMPUN=7,NUMRDR=1,
PASSWORD=(NOTSET),RMT150=NO,ROUTECDE=11,
SETUP=MSG,START=NO,WAITIME=1
The results of this command are: - JES2 creates an SNA RJE workstation with seven punches, one printer,
and no console.
- Because the RJE workstation has no console, JES2 spools messages
to the printer.
|