(2748, 2757, 2763, 2778, 2780, 2782, 5703, 5709) Reference codes

If the error is reported on the control panel, the unit reference code is characters 5 through 8 of the top 16 character line of function 11. If the error is reported on the console, the unit reference code is the 4 rightmost characters of word 1.

Find the unit reference code in the following table.

For more on the Failing Item column entries, see Table 2. Failing Items Details, which follows the reference code table below.

Table 1. (2748, 2757, 2763, 2778, 2780, 2782, 5703, 5709) Reference codes

Reference Code Description/Action Perform all actions before exchanging Failing Items Failing Item
1310 I/O processor resource not available

The I/O processor error log is being filled faster than the errors are being reported to the system. Check other errors reported to the system and correct them.


3006 System bus error
3020 I/O processor detected a SCSI bus configuration error

Error occurred on SCSI bus 0. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices.

3021 I/O processor detected a SCSI bus configuration error

Error occurred on SCSI bus 1. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices.

3022 I/O processor detected a SCSI bus configuration error

Error occurred on SCSI bus 2. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices.

3023 I/O processor detected a SCSI bus configuration error

Error occurred on SCSI bus 3. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices.

3100 I/O processor card detected interface error

Error occurred on SCSI bus 0.

Perform IOPIP13.

3101 I/O processor card detected interface error

Error occurred on SCSI bus 1.

Perform IOPIP13.

3102 I/O processor card detected interface error

Error occurred on SCSI bus 2.

Perform IOPIP13.

3103 I/O processor card detected interface error

Error occurred on SCSI bus 3.

Perform IOPIP13.

3120 I/O Processor detected that the bus is not operational

A device was added to SCSI bus 0 of the I/O Adapter and caused the bus to become not operational. Remove the device.

3121 I/O Processor detected that the bus is not operational

A device was added to SCSI bus 1 of the I/O Adapter and caused the bus to become not operational. Remove the device.

3122 I/O Processor detected that the bus is not operational

A device was added to SCSI bus 2 of the I/O Adapter and caused the bus to become not operational. Remove the device.

3123 I/O Processor detected that the bus is not operational

A device was added to SCSI bus 3 of the I/O Adapter and caused the bus to become not operational. Remove the device.

3140 I/O Processor detected that the bus is now operational

This reference code and the 3120 reference code that occurred before it require no service action, since SCSI bus 0 is now operational.


3141 I/O Processor detected that the bus is now operational

This reference code and the 3121 reference code that occurred before it require no service action, since SCSI bus 1 is now operational.


3142 I/O Processor detected that the bus is now operational

This reference code and the 3122 reference code that occurred before it require no service action, since SCSI bus 2 is now operational.


3143 I/O Processor detected that the bus is now operational

This reference code and the 3123 reference code that occurred before it require no service action, since SCSI bus 3 is now operational.


3150 I/O processor detected a SCSI bus configuration error

Internal and external SCSI cables are connected to SCSI bus 0 at the same time. Correct the SCSI bus 0 configuration.

3151 I/O processor detected a SCSI bus configuration error

Internal and external SCSI cables are connected to SCSI bus 1 at the same time. Correct the SCSI bus 1 configuration.

3400 I/O processor card detected device error
3401 Device backplane problem
3501 I/O processor Licensed Internal Code error
3600 to 3601 System log entry only, no service action required

8008 A permanent cache battery pack failure occurred

NOTE: Under a certain configuration, this SRC may not represent an error that requires a service action. Depending on the configuration of the system, the Storage IOA may have been altered and/or the Storage IOA Cache may have been disabled to allow attachment of OEM Storage that emulates a Load Source drive. If this is the case, this error will be posted each time the IOA is IPLed and it can be ignored.

8009 Impending cache battery pack failure
8012 Attached read cache devices exceed capacity supported by IOA

Reduce the number of read caches on the IOA.

8100 I/O processor Licensed Internal Code error
8130 IOA detected recoverable device bus error

An error occurred on SCSI bus 0. No action is required. This reference code is logged for information only.


8131 IOA detected recoverable device bus error

An error occurred on SCSI bus 1. No action is required. This reference code is logged for information only.


8132 IOA detected recoverable device bus error

An error occurred on SCSI bus 2. No action is required. This reference code is logged for information only.


8133 IOA detected recoverable device bus error

An error occurred on SCSI bus 3. No action is required. This reference code is logged for information only.


8140 IOA detected recoverable device bus error

No action is required. This reference code is logged for information only.


8141 IOA detected recoverable device error

No action is required. This reference code is logged for information only.


8145 A recoverable I/O processor error occurred.
8146 Disk device detected recoverable error
8150 A permanent I/O processor failure occurred

NOTE: Under a certain configuration, this SRC may not represent an error that requires a service action. Depending on the configuration of the system, the Storage IOA may have been altered and/or the Storage IOA Cache may have been disabled to allow attachment of OEM Storage that emulates a Load Source drive. If this is the case, this error will be posted each time the IOA is IPLed and it can be ignored.

8151 I/O processor Licensed Internal Code error
8155 to 8156 A permanent I/O processor failure occurred
8157 I/O adapter card error

Display the Service Action Log entry for this SRC. If the Failing Item indicates I/O adapter, then replace the I/O adapter. If the Failing Item indicates SVCDOCS, then do NOT replace the I/O adapter. This is a recoverable error. Perform the following for the I/O processor that the I/O adapter is attached to:

1. If the I/O Processor is not operable and disk units are attached, use Hardware Service Manager to re-IPL the IOP. Other resources attached to the IOP may then need to be Varied On.

2. If disk units are not attached, perform the VRYCFG RESET(*YES) command to reset the IOP and Vary On attached resources.

8200 I/O processor Licensed Internal Code error
9000 I/O processor card detected device error
9001 I/O processor card detected device configuration error

Perform IOPIP33.

9002 I/O processor card detected device error

Perform IOPIP16.

9008 I/O card does not support functions expected by devices

Perform IOPIP25.

9009 Call your next level of support for assistance
9010 Cache data associated with attached devices cannot be found

Perform IOPIP31.

9011 Cache data belongs to devices other than those attached

Perform IOPIP32.

9014 Mode jumper overridden due to cache data in conflicting mode

See JOVERRIDE.

9015 Mode jumper missing

See JMISSING.

9020 to 9021 Array not functional due to present hardware configuration.

Perform IOPIP20.

9022 to 9024 Array not functional due to present hardware configuration.

Perform IOPIP22.

9025 Disk unit is not supported at its physical location.

Perform IOPIP21.

9026 Array not functional due to present hardware configuration.

Perform IOPIP22.

9027 Array not functional due to present hardware configuration.

Perform IOPIP34.

9028 Incorrect hardware configuration change has been detected.

Reduce the number of arrays on IOP. Either move all devices in an array to another IOP that supports arrays, or stop an array on this IOP.

9029 Incorrect hardware configuration change has been detected.

Contact your next level of support.

902F Array addendum Product Activity Log entry

This entry contains additional array information for 90xx reference codes when the array contains more than 10 array members. Use the 90xx entry that occurred at the same time as this reference code as the starting point for this problem.


9030 Array no longer protected due to missing or failed disk unit

Perform IOPIP21.

9031 Automatic rebuild initiated for array

Either a previous rebuild was interrupted and was automatically restarted, or a hot spare disk unit was used to automatically rebuild the array. Look for other reference codes and take action on them.


9032 A disk unit in an array is missing or failed

The array is still protected, but the disk unit should be replaced.

Perform IOPIP21.

9040 Array protection temporarily suspended

No action required. Protection will be automatically restarted.


9041 Background array parity check detected and corrected errors

Call your next level of support to report the problem.

9042 An array parity error has been detected and corrected

Call your next level of support to report the problem.

9050 Required cache data cannot be located for a disk unit.

Perform IOPIP30.

9051 IOP cache data exists for a missing or failed device.

If all configured units are missing, a 9054 reference code may appear in the product activity log. If so, perform the action indicated for the 9054 reference code.

Otherwise, perform IOPIP27.

9052 Cache data exists for device that has been modified.

Contact your next level of support.

9053 IOP resources not available due to previous problems.

Take action on other IOP reference codes which have surfaced.

If you cannot get to SST or DST, and cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other IOP reference codes and take action on them.

9054 IOP resources not available due to previous problems.

Power off the system and remove all new or replacement disk units. IPL the system to DST. If you cannot perform a type A or B IPL, perform a type D IPL from removable media.

Look for Product Activity Log entries for other IOP reference codes and take action on them.

9071 Link from IOA to auxiliary cache IOA went operational

No service action required.


9072 Link from IOA to auxiliary cache IOA went non-operational

No service action required.


9073 Incompatible or non-operational auxiliary cache IOA attached

Perform IOPIP40.

9081 I/O processor card detected device error
9082 I/O processor card detected device error

Perform IOPIP16.

9090 Disk unit has been modified after the last known status.

Re-IPL the system. If any reference codes are surfaced, go to List of system reference codes and use the new reference code as the entry point to the problem.

If you cannot resolve the problem, contact your next level of support.

9091 Incorrect hardware configuration change has been detected.

Re-IPL the system. If any reference codes are surfaced, go to List of system reference codes and use the new reference code as the entry point to the problem.

If you cannot resolve the problem, contact your next level of support.

9092 Disk unit requires initialization before use.

Perform IOPIP26.

9093 Read cache device not in correct format

Contact your next level of support.

B934 Incompatible hardware detected.
FF3D I/O adapter detected a recoverable error
FF6D I/O processor detected a recoverable system bus error

Table 2. Failing items details

Failing Item Description Document Description
AJDGP01 I/O processor Licensed Internal Code Service Functions; APAR or LICTR
ANYBRDG System I/O bus or any attached card See the service documentation for instructions.
ANYBUS IOP card bus error See the service documentation for instructions.
BACKPLN Card Enclosure or Planar Board See the service documentation for instructions.
CACHBAT Cache battery pack See the service documentation for instructions.
DEVBPLN Device backplane See the service documentation for instructions.
DEVTERM Terminating plug See the service documentation for instructions.
IOP I/O processor card See the service documentation for instructions.
NEXTLVL Call your next level of support for assistance See the service documentation for instructions.
PCIBUS Any PCI card on the PCI bus See the service documentation for instructions.
STORIOA Storage I/O adapter See the service documentation for instructions.
SVCDOCS Customer engineer directed to system problem analysis See the service documentation for instructions.
USER System Operator/User See the service documentation for instructions.