(B075) Workstation adapter console reference codes

The workstation adapter console detected a failure.

  1. Look at characters 5 through 8 of the top 16 character line of function 11 (4 rightmost characters of word 1). These 4 characters are the unit reference code.
  2. Find the unit reference code in the following table.

For more on the Failing Item column entries, see Table 2. Workstation adapter console failing items details, which follows the reference code table below.

Table 1. (B075) Workstation adapter console reference codes

Reference Code Description/Action Perform all actions before exchanging Failing Items Failing Item
0101 WS IOP detected error when transmitting data

Perform WSCIP01.

0103 WS IOP detected parity error from device

Perform WSCIP01.

0104 Device detected parity error from WS IOP

Perform WSCIP01.

0105 WS IOP detected error when transmitting data

Perform WSCIP01.

0106 WS IOP detected wrong data from device

Perform WSCIP01.

0107 WS IOP detected wrong address from device

Perform WSCIP01.

FI00601
GXC7777
FI00730
0108 WS IOP detected device power turned off, and then on

Perform WSCIP01.

GXCEEEE
FI00601
0109 WS IOP detected wrong device response to start command

Perform WSCIP01.

0111 WS IOP detected wrong keyboard scan code from display

Perform WSCIP01.

0120 Device detected wrong command or device ID from WS IOP

Perform WSCIP01.

0121 Device detected not valid value from WS IOP

Perform WSCIP01.

0122 Device detected storage or data overrun

Perform WSCIP01.

0123 Device detected null or attribute exception error

Perform WSCIP01.

0124 Device detected wrong start command from WS IOP

Perform WSCIP01.

0125 WS IOP detected wrong exception response from device

Perform WSCIP01.

0126 WS IOP detected not valid pass-through command

Perform WSCIP01.

GXC9999
FI00730
0149 WS IOP detected wrong request or response from device

Perform WSCIP01.

0190 WS IOP detected no status change from device

Perform WSCIP01.

FI00601
GXC7777
FI00730
0191 WS IOP detected busy time-out from device

Perform WSCIP01.

0201 WS IOP detected error when transmitting data

Perform WSCIP01.

0203 WS IOP detected parity error from device

Perform WSCIP01.

0204 Device detected parity error from WS IOP

Perform WSCIP01.

0205 WS IOP detected error when transmitting data

Perform WSCIP01.

0206 WS IOP detected wrong data from device

Perform WSCIP01.

0207 WS IOP detected wrong address from device

Perform WSCIP01.

FI00604
GXC7777
FI00730
0208 WS IOP detected device power turned off, and then on
GXCEEEE
FI00604
0209 WS IOP detected wrong device response to start command
0211 Printer detected equipment error
0221 Device detected not valid value from WS IOP
0224 Device detected wrong start command from WS IOP
0225 WS IOP detected wrong exception response from device
0290 WS IOP detected no status change from device
0291 WS IOP detected busy time-out from device
5000 Wrong command sent by Licensed Internal Code
AJDG301
5001 Procedure error in Licensed Internal Code
AJDG301
5002 Procedure error in Licensed Internal Code

Procedure error in machine instructions

CXCTEMP
AJDG301
5006 Procedure error in Licensed Internal Code
AJDG301
5007 Procedure error in Licensed Internal Code
AJDG301
CXCMSTA
5009 Incorrect command value sent by Licensed Internal Code
AJDG301
500A Procedure error in Licensed Internal Code
AJDG301
500D Incorrect command value sent by Licensed Internal Code
AJDG301
CXCMAXI
5022 Procedure error in Licensed Internal Code
AJDG301
5206 Communications controller storage not available
CXCBUSY
56EA Clear-to-send signal dropped on modem interface
GXCLINK
FI00704
CXCCTSV
FI00719
FI00701
56ED Data-set-ready turn-on time-out on modem interface
56F1 Data-set-ready dropped on modem interface
5710 Nonproductive receive time-out while receiving from remote
5712 No data received from remote equipment; time-out
AJLAG01
CXCENCD
CXCINAT
GXCLINK
FI00704
FI00705
FI00700
CXCSTAD
FI00701
CXCDTAR
FI00719
CXCMRTY
5715 Remote equipment did not respond causing an idle-time-out
GXCLINK
CXCRPTO
FI00701
FI00704
CXCMRTY
FI00705
CXCENCD
FI00700
CXCDTAR
FI00719
5718 Retry limit reached for sending frames to remote equipment
5719 Retry limit reached for sending frames to remote equipment
5720 Retry limit reached for sending poll frame to remote
FI00700
CXCMODU
5721 Could not send frame to remote equipment; local problem
5722 Wrong command value sent by OS/400 licensed program
AJLAG01
CXCSTAD
A000 Too many devices active on the workstation IOP
GXCBBBB
B000 WS IOP fails to report part, model and serial number

Perform WSCIP01.

C000, D000 WS IOP error not known
AJLAG01
D001 Wrong or no external communications cable installed
FI00631
AJLAG01
F003 WS IOA buffer utilization threshold exceeded temporarily
AJLAG01
FFFF User believes there is a problem

Reference code FFFF is assigned by the ANZPRB (Analyze Problems) for user-detected errors. Run ANZPRB again if the problem still exists or look in the problem log (WRKPRB) for possible failing FRUs.

UXCFF00

Table 2. Workstation adapter console failing items details

Failing Item Description Document Description
AJDG301 Vertical Licensed Internal Code Service Functions; APAR or LICTR
AJLAG01 Licensed Internal Code Service Functions; APAR or LICTR
CXCBUSY Too many communications lines in use Communications Configuration
CXCCONF Configuration or OS/400 licensed program Communications Configuration
CXCCPTO CNNPOLLTMR value in CRTLINSDLC command Communications Configuration
CXCCTSV CTSTMR value in CRTLINSDLC command Communications Configuration
CXCDTAR LINESPEED value in CRTLINSDLC command Communications Configuration
CXCENCD NRZI value in CRTLINSDLC command Communications Configuration
CXCINAT INACTTMR value in CRTLINSDLC command Communications Configuration
CXCMAXI MAXFRAME value in CRTLINSDLC command Communications Configuration
CXCMODU MODULUS value in CRTLINSDLC command Communications Configuration
CXCMRTY FRAMERTY value in CRTLINSDLC command Communications Configuration
CXCMSTA MAXCTL value in CRTLINSDLC command Communications Configuration
CXCNPRT NPRDRCVTMR value in CRTLINSDLC command Communications Configuration
CXCRPTO IDLTMR value in CRTLINSDLC command Communications Configuration
CXCSNDT SHMNODE value in CRTLINSDLC command Communications Configuration
CXCSTAD STNADR value in CRTCTL_____command Communications Configuration
CXCTEMP No failure found Communications Configuration
GXC7777 Electrical interference
GXC8888 Other workstation on port is failing
GXC9999 Error occurred with pass-through command
GXCBBBB Too many devices are active on the workstation IOP
GXCEEEE Active device turned off
GXCLINK Communications network equipment
UXCFF00 User suspected problem

Send feedback |  Rate this page