(B008) Reference codes

This SRC might indicate a communications error.

Find the unit reference code in the following table. For more on the Failing Item column entries, see Table 2. Failing items details, which follows the reference code table below.

Table 1. (B008) Reference codes

Reference Code Description/Action Perform all actions before exchanging Failing Items Failing Item
1200 Communications controller task ended abnormally; type 1
1201 Communications controller task ended abnormally; type 2
1202 Communications controller task ended abnormally; type 3
1701 Disconnect mode frame received
1702 Disconnect mode frame received during link activation
1703 Disconnect mode frame received when transmitting information
1704 Frame reject type W received
1705 Frame reject type X received
1706 Frame reject type Y received
1707 Frame reject type Z received
1708 Frame reject type W sent
1709 Frame reject type X sent
170A Frame reject type Y sent
170B Frame reject type Z sent
170C Frame retry limit reached
170D Set-asynchronous-balance-mode frame received in data mode
170E Wrong response received from remote equipment
2651 First call failed, retrying call; no CFI from modem
2652 First call failed, retrying call; CFI AB from modem
2653 First call failed, retrying call; CFI DE from modem
2654 First call failed, retrying call; CFI ET from modem
2656 First call failed, retrying call; CFI NT from modem
2657 First call failed, retrying call; CFI RT from modem
2660 Call failed, retrying call; Non-standard CFI from modem
450A Incorrect command value sent by Licensed Internal Code
4590 Wrong telephone number specified in system configuration
4592 No number specified in controller description
4594 Wrong telephone number specified in system configuration
5000 Wrong command received by communications controller
5002 Wrong procedure followed by I/O card Licensed Internal Code
5008 Procedure error in Licensed Internal Code
5009, 500B to 500C Wrong command value received by communications IOP
500D Wrong data length received by communications controller
500E to 500F Wrong command value received by communications IOP
5010 Wrong reset option received by communications controller
5011 Wrong command value received by communications IOP
5012 Wrong session ID received by communications controller
5014 Wrong command value received by communications IOP
5015 Communications line already in use
5016 Wrong command value received by communications IOP
5017 Wrong storage value received by communications controller
5018 Wrong trace type received by communications controller
5019 Wrong trace length received by communications controller
501A Communications controller temporary storage area too small
501B Wrong ID length value sent by vertical LIC
501C, 501E to 501F Wrong command value received by communications IOP
5022 Port already in use
5023 Procedure error in Licensed Internal Code
5024 DTE/DCE role negotiation not valid for leased line
50E0 Wrong or no external communications cable installed
50E1 Port already in use
50E3 Wrong command value sent by OS/400 licensed program
50E4 Wrong command value sent by OS/400 licensed program
50E5 Wrong adapter type value sent by Licensed Internal Code
50E6 Wrong slot number value sent by Licensed Internal Code
50E7 Incorrect command value sent by Licensed Internal Code
50E8 to 50E9, 50EC to 50EE Wrong command value sent by OS/400 licensed program
50F1 Communications adapter card not installed
50F2 V.25 adapter not installed
50F5 Network uncontrolled-not-ready warning; information only
50F6 Network controlled-not-ready warning; information only
50F7 Data-set-ready changed to not active; for information only
5203 I/O card Licensed Internal Code resource not available
5206 Communications controller storage not available
52E0 Incorrect command used by I/O card Licensed Internal Code
52E1 Wrong procedure followed by I/O card Licensed Internal Code
52E2 I/O card Licensed Internal Code resource not available
52E3 Wrong response sent by I/O card Licensed Internal Code
52E4 Wrong command value sent by OS/400 licensed program
52E5 Wrong command value received by communications IOP
52E7 X.21 network not in the ready or receive-data state
52E8 Error when releasing communications controller storage
52E9 Error when assigning communications controller storage
52EA I/O card Licensed Internal Code error
5301 Adapter card receive error
5302 Adapter card transmit error
5401 Communications IOP interrupt not expected
5410 Data-set-ready error on modem interface
5472 Data-line-occupied initially 'on' error
5474 Automatic call unit has data-line-occupied error
5476 Automatic call unit has present-next-digit error
54E1 Port not operational
5600 Clear-to-send off; error limit per 256 reached
5601 Data-set-ready state changed; error limit per 256 reached
5602 Clear-to-send state changed; error limit per 256 reached
5603 Carrier-detect state changed; error limit per 256 reached
560B Data-set-ready error; error limit per 256 reached
5630 Automatic call unit has distant-station-connected error
5632 Automatic call unit has data-set-ready error
5651 Call failed, no Call Failure Indication from modem
56E8 Clear-to-send not active on modem interface
56E9 Clear-to-send signal failed to drop on modem interface
56EA Clear-to-send signal dropped on modem interface
56EB Carrier-detect dropped on modem interface
56EC Data-set-ready signal turn-off time-out
56ED Data-set-ready signal turn-on time-out
56F1 Data-set-ready dropped on modem interface
5718 SABM response or UA command received
5719 Protocol mismatch during link initialization
5721 Could not send frame to remote equipment; local problem
57E0 Frame check error; error limit per 256 reached
57E1 Overrun error; error limit per 256 reached
57E2 Short frame error; error limit per 256 reached
57E3 Abnormal end received; error limit per 256 reached
57E4 Underrun threshold error; limit per 256 reached
57E5 Long frame; error limit per 256 reached
57F0 Send sequence counter error; error limit per 256 reached
57F1 Receive sequence counter error; error limit per 256 reached
57F2 Response time-out error; error limit per 256 reached
5886 Automatic call unit switched link time-out; no answer
5E01 Call error; incoming call received during outgoing call
6320 Automatic call unit has abandon-call attempt
6322 Abandon call retry error; incorrect number length
6870 Automatic call unit power turned off
8011 IOP activation failed.

The MDMCNTRYID parameter in Network Attributes is not set. Use the CHGNETA command to set MDMCNTRYID.

8013 IOP activation failed.

The MDMCNTRYID parameter in Network Attributes is not valid for this adapter. Use the CHGNETA command to change the MDMCNTRYID value.

8020 User suspected communications problem.

D230 ISDN channel hardware not operational
74F1624
FI00730
DA00 The I/O card LIC detected an internal error
DA01 The I/O card LIC detected an internal error
FFFF User suspected communications problem.

Table 2. Failing items details

Failing Item Description Document Description
74F1624 ISDN channel hardware Repair and Parts; removal and installation procedures
AJDG301 Licensed Internal Code See the service documentation for instructions.
IOA Communications adapter card Repair and Parts; removal and installation procedures
IOP Communications I/O processor card Repair and Parts; removal and installation procedures
UJ0E3 Communications network equipment
UJ0E9 Communications network equipment
UJA35 CNNNBR value in CRTLINX25___command Communications Configuration
UJE34 Configuration or OS/400 licensed program Communications Configuration
UJE34 No failure found Communications Configuration
UJJ35 MAXPKTSIZE in CRTLINX25 command Communications Configuration
UJJ35 ACRSRCNAME value in CRTLINX25 command Communications Configuration
UJJ35 FRAMERTY value in CRTLINX25 command Communications Configuration
UJJ35 X25DCE value in CRTLINX25 command Communications Configuration
UJJ35 DSRDRPTMR value in the CRTLINX25 command Communications Configuration
UJJ35 INTERFACE value in CRTLINX25 command Communications Configuration
UJJ35 DFTWDWSIZE value in CRTLINX25 command Communications Configuration
UJJ35 RMTANSTMR value in the CRTLINX25 command Communications Configuration
UJJ35 IDLTMR value in CRTLINX25 command Communications Configuration
UJJ35 RSRCNAME value in CRTLINX25 command Communications Configuration
UJJ35 DIALRTY value in CRTCTL____ command Communications Configuration
UJJ35 CTSTMR value in CRTLINX25 command Communications Configuration
USER User suspected communications problem.

Send feedback |  Rate this page