For more on the Failing Item column entries, see Table 2. Failing Items Details, which follows the reference code table below.
Table 1. (2749, 2767, 2768, 2842, 2843, 2844, 284B, 5702, 570B) Reference codes
Reference Code | Description/Action Perform all actions before exchanging Failing Items | Failing Item |
---|---|---|
0A17 | A permanent I/O processor failure occurred | |
0A22 | I/O processor detected a storage transfer error | |
102E | Out of alternate sectors for disk storage | |
1306 | I/O processor card or Licensed Internal Code error
A microprocessor exception occurred on the I/O processor. |
|
1307 | I/O processor resource not available | |
1310 | I/O processor resource not available
The I/O processor error log is being filled faster than the errors are being reported to the system. Check other errors reported to the system and correct them. |
|
1317 | I/O processor card error
Display the Service Action Log entry for this SRC. If the Failing Item indicates IOP, then replace the IOP. If the Failing Item indicates SVCDOCS, then do NOT replace the IOP. This is a recoverable error. Perform the following: 1. If the I/O Processor is not operable and disk units are attached, use Hardware Service Manager to re-IPL the IOP. Other resources attached to the IOP may then need to be Varied On. 2. If disk units are not attached, perform the VRYCFG RESET(*YES) command to reset the IOP and Vary On attached resources. |
|
2200 | I/O processor Licensed Internal Code error | |
2201 | Removable media error during IPL | |
2202 | Removable media error during IPL | |
3000 | A permanent I/O processor failure occurred | |
3001 | Not valid condition in I/O Processor Licensed Internal Code
The Licensed Internal Code found a condition that should not have occurred. |
|
3002 | Addressed device failed to respond to selection
Perform IOPIP16. |
|
3006 | System bus error | |
3020 | I/O processor detected a SCSI bus configuration error
Error occurred on SCSI bus 0. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. |
|
3021 | I/O processor detected a SCSI bus configuration error
Error occurred on SCSI bus 1. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. |
|
3022 | I/O processor detected a SCSI bus configuration error
Error occurred on SCSI bus 2. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. |
|
3023 | I/O processor detected a SCSI bus configuration error
Error occurred on SCSI bus 3. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. |
|
3080 | I/O processor Licensed Internal Code error | |
3081 | System log entry only, no service action required |
|
3084 | I/O processor card or Licensed Internal Code error
A microprocessor exception occurred on the I/O processor. |
|
3087 | I/O processor resource not available
The Licensed Internal Code could not allocate resources on the I/O processor card. |
|
3100 | I/O processor card detected interface error
Error occurred on SCSI bus 0. Perform IOPIP13. |
|
3101 | I/O processor card detected interface error
Error occurred on SCSI bus 1. Perform IOPIP13. |
|
3102 | I/O processor card detected interface error
Error occurred on SCSI bus 2. Perform IOPIP13. |
|
3103 | I/O processor card detected interface error
Error occurred on SCSI bus 3. Perform IOPIP13. |
|
3109 | I/O processor timed out a device command
Perform IOPIP16. |
|
3110 | I/O processor card detected interface error
Perform IOPIP16. |
|
3120 | I/O Processor detected that the bus is not operational
A device was added to SCSI bus 0 of the I/O Adapter and caused the bus to become not operational. Remove the device. |
|
3121 | I/O Processor detected that the bus is not operational
A device was added to SCSI bus 1 of the I/O Adapter and caused the bus to become not operational. Remove the device. |
|
3122 | I/O Processor detected that the bus is not operational
A device was added to SCSI bus 2 of the I/O Adapter and caused the bus to become not operational. Remove the device. |
|
3123 | I/O Processor detected that the bus is not operational
A device was added to SCSI bus 3 of the I/O Adapter and caused the bus to become not operational. Remove the device. |
|
3136 | The removable media device is assigned elsewhere | |
3140 | I/O Processor detected that the bus is now operational
This reference code and the 3120 reference code that occurred before it require no service action, since SCSI bus 0 is now operational. |
|
3141 | I/O Processor detected that the bus is now operational
This reference code and the 3121 reference code that occurred before it require no service action, since SCSI bus 1 is now operational. |
|
3142 | I/O Processor detected that the bus is now operational
This reference code and the 3122 reference code that occurred before it require no service action, since SCSI bus 2 is now operational. |
|
3143 | I/O Processor detected that the bus is now operational
This reference code and the 3123 reference code that occurred before it require no service action, since SCSI bus 3 is now operational. |
|
3150 | I/O processor detected a SCSI bus configuration error
Internal and external SCSI cables are connected to SCSI bus 0 at the same time. Correct the SCSI bus 0 configuration. |
|
3151 | I/O processor detected a SCSI bus configuration error
Internal and external SCSI cables are connected to SCSI bus 1 at the same time. Correct the SCSI bus 1 configuration. |
|
3200 | A tape/CD or disk device reported a failure | |
3203 | Disk media format bad | |
3205, 3215 | Disk sector read error
Disk unit data may need to be reloaded, but the disk unit does not need to be replaced. |
|
3250 | Disk unit requires initialization before use.
Perform a D-IPL and work on errors found in the log. |
|
3300 | Storage unit detected a media problem
Perform IOPIP01. |
|
3400 | I/O processor card detected device error
NOTE: If external devices are attached check EXTSCSI and DEVTERM first. |
|
3401 | Device backplane problem | |
3501 | I/O processor Licensed Internal Code error | |
3600 to 3601 | System log entry only, no service action required |
|
6070 | A permanent I/O processor failure occurred | |
6071 | I/O processor Licensed Internal Code error | |
6072 | I/O processor Licensed Internal Code error | |
6073 | IPL device not ready | |
6075 | I/O processor resource not available | |
6076 | I/O processor card detected media error | |
6081 to 6083 | I/O processor Licensed Internal Code error | |
6085 | I/O processor Licensed Internal Code error | |
6200 | A permanent IOA hardware error occurred | |
6201 | IOA LID is not valid | |
6602 | An I/O processor Licensed Internal Code error occurred. | |
8000 | A permanent IOP or cache adaptor card failure occurred.
Note:
DO NOT replace both FRUs at the same time. Exchange
the FRUs one at a time in the order shown. |
|
8002 | A permanent cache adaptor card failure occurred.
Note:
DO NOT replace both FRUs at the same time. Exchange
the FRUs one at a time in the order shown. |
|
8004 | Voltage drop detected on I/O processor 5 volt power supply. | |
8005 | A recoverable IOP or cache adaptor card error occurred.
Note:
DO NOT replace both FRUs at the same time. Exchange
the FRUs one at a time in the order shown. |
|
8007 | A recoverable cache adaptor card error occurred.
Note:
DO NOT replace both FRUs at the same time. Exchange
the FRUs one at a time in the order shown. |
|
8010 to 8011 | A permanent cache adaptor card failure occurred.
The cache adaptor card may be missing, broken or incompatible. Note:
DO NOT replace both FRUs at the same time. Exchange
the FRUs one at a time in the order shown. |
|
8100 | I/O processor Licensed Internal Code error | |
8130 | IOA detected recoverable device bus error
An error occurred on SCSI bus 0. No action is required. This reference code is logged for information only. |
|
8131 | IOA detected recoverable device bus error
An error occurred on SCSI bus 1. No action is required. This reference code is logged for information only. |
|
8132 | IOA detected recoverable device bus error
An error occurred on SCSI bus 2. No action is required. This reference code is logged for information only. |
|
8133 | IOA detected recoverable device bus error
An error occurred on SCSI bus 3. No action is required. This reference code is logged for information only. |
|
8140 | IOA detected recoverable device bus error
No action is required. This reference code is logged for information only. |
|
8141 | IOA detected recoverable device error
No action is required. This reference code is logged for information only. |
|
8145 | A recoverable I/O processor error occurred. | |
8146 | Disk device detected recoverable error | |
8150 | A permanent I/O processor failure occurred | |
8151 | I/O processor Licensed Internal Code error | |
8155 to 8156 | A permanent I/O processor failure occurred | |
8157 | I/O adapter card error
Display the Service Action Log entry for this SRC. If the Failing Item indicates I/O adapter, then replace the I/O adapter. If the Failing Item indicates SVCDOCS, then do NOT replace the I/O adapter. This is a recoverable error. Perform the following for the I/O processor that the I/O adapter is attached to: 1. If the I/O Processor is not operable and disk units are attached, use Hardware Service Manager to re-IPL the IOP. Other resources attached to the IOP may then need to be Varied On. 2. If disk units are not attached, perform the VRYCFG RESET(*YES) command to reset the IOP and Vary On attached resources. |
|
8200 | I/O processor Licensed Internal Code error | |
8300 | I/O processor card or Licensed Internal Code error
A microprocessor exception occurred on the I/O processor. |
|
8301 | Not valid condition in I/O Processor Licensed Internal Code
The Licensed Internal Code found a condition that should not have occurred. |
|
8400 | I/O processor Licensed Internal Code error | |
9000 | I/O processor card detected device error | |
9001 | I/O processor card detected device configuration error
Perform IOPIP33. |
|
9002 | I/O processor card detected device error
Perform IOPIP16. |
|
9008 | I/O card does not support functions expected by devices
Perform IOPIP25. |
|
9009 | Call your next level of support for assistance | |
9010 | Cache data associated with attached devices cannot be found
Perform IOPIP31. |
|
9011 | Cache data belongs to devices other than those attached
Perform IOPIP32. |
|
9012 | IOP requires a cache adaptor card but cannot find it.
The cache adapter card is missing or broken. Perform IOPIP29. |
|
9013 | The IOP and attached cache adaptor card are not compatible.
Perform IOPIP19. |
|
9020 to 9021 | Array not functional due to present hardware configuration.
Perform IOPIP20. |
|
9022 to 9024 | Array not functional due to present hardware configuration.
Perform IOPIP22. |
|
9025 | Disk unit is not supported at its physical location.
Perform IOPIP21. |
|
9026 | Array not functional due to present hardware configuration.
Perform IOPIP22. |
|
9027 | Array not functional due to present hardware configuration.
Perform IOPIP34. |
|
9028 | Incorrect hardware configuration change has been detected.
Reduce the number of arrays on IOP. Either move all devices in an array to another IOP that supports arrays, or stop an array on this IOP. |
|
9029 | Incorrect hardware configuration change has been detected.
Contact your next level of support. |
|
902F | Array addendum Product Activity Log entry
This entry contains additional array information for 90xx reference codes when the array contains more than 10 members. Use the 90xx entry that occurred at the same time as this reference code as the starting point for this problem. |
|
9030 | Array no longer protected due to missing or failed disk unit
Perform IOPIP21. |
|
9031 | Automatic rebuild initiated for array
Either a previous rebuild was interrupted and was automatically restarted, or a hot spare disk unit was used to automatically rebuild the array. Look for other reference codes and take action on them. |
|
9040 | Array protection temporarily suspended
No action required. Protection will be automatically restarted. |
|
9041 | Background array parity check detected and corrected errors
Call your next level of support to report the problem. |
|
9050 | Required cache data cannot be located for a disk unit.
Perform IOPIP30. |
|
9051 | IOP cache data exists for a missing or failed device.
If all configured units are missing, a 9054 reference code may appear in the product activity log. If so, perform the action indicated for the 9054 reference code. Otherwise, perform IOPIP27. |
|
9052 | Cache data exists for device that has been modified.
Perform IOPIP28. |
|
9053 | IOP resources not available due to previous problems.
Take action on other IOP reference codes which have surfaced. If you cannot get to SST or DST, and cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other IOP reference codes and take action on them. |
|
9054 | IOP resources not available due to previous problems.
Power off the system and remove all new or replacement disk units. IPL the system to DST. If you cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other IOP reference codes and take action on them. |
|
9081 | I/O processor card detected device error | |
9082 | I/O processor card detected device error
Perform IOPIP16. |
|
9090 | Disk unit has been modified after the last known status.
Re-IPL the system. If any reference codes are surfaced, go to List of system reference codes and use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. |
|
9091 | Incorrect hardware configuration change has been detected.
Re-IPL the system. If any reference codes are surfaced, go to List of system reference codes and use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. |
|
9092 | Disk unit requires initialization before use.
Perform IOPIP26. |
|
B3B1 to B3B7 | A permanent I/O processor failure occurred | |
B3B8 | Multi-adapter bridge error detected. | |
B3B9 | A permanent I/O processor failure occurred | |
B3E0 to B3E1 | I/O processor detected a fault condition. | |
B410 to B411 | A permanent I/O processor failure occurred | |
B412 | Tape/CD or disk bus interface error occurred
Perform IOPIP16. |
|
B935 | Unknown hardware detected | |
BE00 | I/O processor detected a fault condition. | |
FF3D | I/O adapter detected a recoverable error | |
FF6D | I/O processor detected a recoverable system bus error |
Table 2. Failing items details
Failing Item | Description | Document Description |
---|---|---|
AJDG301 | Vertical Licensed Internal Code | Service Functions; APAR or LICTR |
AJDGP01 | I/O card Licensed Internal Code | Service Functions; APAR or LICTR |
AJDGP01 | I/O processor Licensed Internal Code | Service Functions; APAR or LICTR |
ANYBRDG | System I/O bus or any attached card | See the service documentation for instructions. |
ANYBUS | IOP card bus error | See the service documentation for instructions. |
BACKPLN | Card Enclosure or Planar Board | See the service documentation for instructions. |
CACHBAT | Cache battery pack | See the service documentation for instructions. |
CACHE | Cache adaptor card | See the service documentation for instructions. |
CMPRES1 | Compressed device and compression IOA are not compatible | See the service documentation for instructions. |
CTLPNL | Control panel, or the interface to the Control panel | See the service documentation for instructions. |
DEVBPLN | Device backplane | See the service documentation for instructions. |
DEVTERM | Terminating plug | See the service documentation for instructions. |
FCIOA | Fibre Channel IOA | See the service documentation for instructions. |
IOACNFG | Configuration error | See the service documentation for instructions. |
IOP | I/O processor card | See the service documentation for instructions. |
MA_BRDG | Multi-adapter bridge | See the service documentation for instructions. |
MEDIA | Defective media | See the service documentation for instructions. |
OPT_CLN | Fiber optic cleaning kit | See the service documentation for instructions. |
PCIBUS | Any PCI card on the PCI bus | See the service documentation for instructions. |
STORIOA | Storage I/O adapter | See the service documentation for instructions. |
SVCDOCS | Customer engineer directed to system problem analysis | See the service documentation for instructions. |
USER | System Operator/User | See the service documentation for instructions. |