(2749, 2767, 2768, 2842, 2843, 2844, 284B, 5702, 570B) Reference codes

  1. If the error is reported on the control panel, the unit reference code is characters 5 through 8 of the top 16 character line of function 11. If the error is reported on the console, the unit reference code is the 4 rightmost characters of word 1.
  2. Find the unit reference code in the following table.
Attention: The 673x is a read cache. Perform all actions required for 673x as a disk drive and logic card except where separate 673x cache instructions are provided.

For more on the Failing Item column entries, see Table 2. Failing Items Details, which follows the reference code table below.

Table 1. (2749, 2767, 2768, 2842, 2843, 2844, 284B, 5702, 570B) Reference codes

Reference Code Description/Action Perform all actions before exchanging Failing Items Failing Item
0A17 A permanent I/O processor failure occurred
0A22 I/O processor detected a storage transfer error
102E Out of alternate sectors for disk storage
1306 I/O processor card or Licensed Internal Code error

A microprocessor exception occurred on the I/O processor.

1307 I/O processor resource not available
1310 I/O processor resource not available

The I/O processor error log is being filled faster than the errors are being reported to the system. Check other errors reported to the system and correct them.


1317 I/O processor card error

Display the Service Action Log entry for this SRC. If the Failing Item indicates IOP, then replace the IOP. If the Failing Item indicates SVCDOCS, then do NOT replace the IOP. This is a recoverable error. Perform the following:

1. If the I/O Processor is not operable and disk units are attached, use Hardware Service Manager to re-IPL the IOP. Other resources attached to the IOP may then need to be Varied On.

2. If disk units are not attached, perform the VRYCFG RESET(*YES) command to reset the IOP and Vary On attached resources.

2200 I/O processor Licensed Internal Code error
2201 Removable media error during IPL
2202 Removable media error during IPL
3000 A permanent I/O processor failure occurred
3001 Not valid condition in I/O Processor Licensed Internal Code

The Licensed Internal Code found a condition that should not have occurred.

3002 Addressed device failed to respond to selection

Perform IOPIP16.

3006 System bus error
3020 I/O processor detected a SCSI bus configuration error

Error occurred on SCSI bus 0. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices.

3021 I/O processor detected a SCSI bus configuration error

Error occurred on SCSI bus 1. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices.

3022 I/O processor detected a SCSI bus configuration error

Error occurred on SCSI bus 2. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices.

3023 I/O processor detected a SCSI bus configuration error

Error occurred on SCSI bus 3. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices.

3080 I/O processor Licensed Internal Code error
3081 System log entry only, no service action required

3084 I/O processor card or Licensed Internal Code error

A microprocessor exception occurred on the I/O processor.

3087 I/O processor resource not available

The Licensed Internal Code could not allocate resources on the I/O processor card.

3100 I/O processor card detected interface error

Error occurred on SCSI bus 0.

Perform IOPIP13.

3101 I/O processor card detected interface error

Error occurred on SCSI bus 1.

Perform IOPIP13.

3102 I/O processor card detected interface error

Error occurred on SCSI bus 2.

Perform IOPIP13.

3103 I/O processor card detected interface error

Error occurred on SCSI bus 3.

Perform IOPIP13.

3109 I/O processor timed out a device command

Perform IOPIP16.

3110 I/O processor card detected interface error

Perform IOPIP16.

3120 I/O Processor detected that the bus is not operational

A device was added to SCSI bus 0 of the I/O Adapter and caused the bus to become not operational. Remove the device.

3121 I/O Processor detected that the bus is not operational

A device was added to SCSI bus 1 of the I/O Adapter and caused the bus to become not operational. Remove the device.

3122 I/O Processor detected that the bus is not operational

A device was added to SCSI bus 2 of the I/O Adapter and caused the bus to become not operational. Remove the device.

3123 I/O Processor detected that the bus is not operational

A device was added to SCSI bus 3 of the I/O Adapter and caused the bus to become not operational. Remove the device.

3136 The removable media device is assigned elsewhere
3140 I/O Processor detected that the bus is now operational

This reference code and the 3120 reference code that occurred before it require no service action, since SCSI bus 0 is now operational.


3141 I/O Processor detected that the bus is now operational

This reference code and the 3121 reference code that occurred before it require no service action, since SCSI bus 1 is now operational.


3142 I/O Processor detected that the bus is now operational

This reference code and the 3122 reference code that occurred before it require no service action, since SCSI bus 2 is now operational.


3143 I/O Processor detected that the bus is now operational

This reference code and the 3123 reference code that occurred before it require no service action, since SCSI bus 3 is now operational.


3150 I/O processor detected a SCSI bus configuration error

Internal and external SCSI cables are connected to SCSI bus 0 at the same time. Correct the SCSI bus 0 configuration.

3151 I/O processor detected a SCSI bus configuration error

Internal and external SCSI cables are connected to SCSI bus 1 at the same time. Correct the SCSI bus 1 configuration.

3200 A tape/CD or disk device reported a failure
3203 Disk media format bad
3205, 3215 Disk sector read error

Disk unit data may need to be reloaded, but the disk unit does not need to be replaced.

3250 Disk unit requires initialization before use.

Perform a D-IPL and work on errors found in the log.

3300 Storage unit detected a media problem

Perform IOPIP01.

3400 I/O processor card detected device error

NOTE: If external devices are attached check EXTSCSI and DEVTERM first.

3401 Device backplane problem
3501 I/O processor Licensed Internal Code error
3600 to 3601 System log entry only, no service action required

6070 A permanent I/O processor failure occurred
6071 I/O processor Licensed Internal Code error
6072 I/O processor Licensed Internal Code error
6073 IPL device not ready
6075 I/O processor resource not available
6076 I/O processor card detected media error
6081 to 6083 I/O processor Licensed Internal Code error
6085 I/O processor Licensed Internal Code error
6200 A permanent IOA hardware error occurred
6201 IOA LID is not valid
6602 An I/O processor Licensed Internal Code error occurred.
8000 A permanent IOP or cache adaptor card failure occurred.

Note:
DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown.
8002 A permanent cache adaptor card failure occurred.

Note:
DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown.
8004 Voltage drop detected on I/O processor 5 volt power supply.
8005 A recoverable IOP or cache adaptor card error occurred.

Note:
DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown.
8007 A recoverable cache adaptor card error occurred.

Note:
DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown.
8010 to 8011 A permanent cache adaptor card failure occurred.

The cache adaptor card may be missing, broken or incompatible.

Note:
DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown.
8100 I/O processor Licensed Internal Code error
8130 IOA detected recoverable device bus error

An error occurred on SCSI bus 0. No action is required. This reference code is logged for information only.


8131 IOA detected recoverable device bus error

An error occurred on SCSI bus 1. No action is required. This reference code is logged for information only.


8132 IOA detected recoverable device bus error

An error occurred on SCSI bus 2. No action is required. This reference code is logged for information only.


8133 IOA detected recoverable device bus error

An error occurred on SCSI bus 3. No action is required. This reference code is logged for information only.


8140 IOA detected recoverable device bus error

No action is required. This reference code is logged for information only.


8141 IOA detected recoverable device error

No action is required. This reference code is logged for information only.


8145 A recoverable I/O processor error occurred.
8146 Disk device detected recoverable error
8150 A permanent I/O processor failure occurred
8151 I/O processor Licensed Internal Code error
8155 to 8156 A permanent I/O processor failure occurred
8157 I/O adapter card error

Display the Service Action Log entry for this SRC. If the Failing Item indicates I/O adapter, then replace the I/O adapter. If the Failing Item indicates SVCDOCS, then do NOT replace the I/O adapter. This is a recoverable error. Perform the following for the I/O processor that the I/O adapter is attached to:

1. If the I/O Processor is not operable and disk units are attached, use Hardware Service Manager to re-IPL the IOP. Other resources attached to the IOP may then need to be Varied On.

2. If disk units are not attached, perform the VRYCFG RESET(*YES) command to reset the IOP and Vary On attached resources.

8200 I/O processor Licensed Internal Code error
8300 I/O processor card or Licensed Internal Code error

A microprocessor exception occurred on the I/O processor.

8301 Not valid condition in I/O Processor Licensed Internal Code

The Licensed Internal Code found a condition that should not have occurred.

8400 I/O processor Licensed Internal Code error
9000 I/O processor card detected device error
9001 I/O processor card detected device configuration error

Perform IOPIP33.

9002 I/O processor card detected device error

Perform IOPIP16.

9008 I/O card does not support functions expected by devices

Perform IOPIP25.

9009 Call your next level of support for assistance
9010 Cache data associated with attached devices cannot be found

Perform IOPIP31.

9011 Cache data belongs to devices other than those attached

Perform IOPIP32.

9012 IOP requires a cache adaptor card but cannot find it.

The cache adapter card is missing or broken.

Perform IOPIP29.

9013 The IOP and attached cache adaptor card are not compatible.

Perform IOPIP19.

9020 to 9021 Array not functional due to present hardware configuration.

Perform IOPIP20.

9022 to 9024 Array not functional due to present hardware configuration.

Perform IOPIP22.

9025 Disk unit is not supported at its physical location.

Perform IOPIP21.

9026 Array not functional due to present hardware configuration.

Perform IOPIP22.

9027 Array not functional due to present hardware configuration.

Perform IOPIP34.

9028 Incorrect hardware configuration change has been detected.

Reduce the number of arrays on IOP. Either move all devices in an array to another IOP that supports arrays, or stop an array on this IOP.

9029 Incorrect hardware configuration change has been detected.

Contact your next level of support.

902F Array addendum Product Activity Log entry

This entry contains additional array information for 90xx reference codes when the array contains more than 10 members. Use the 90xx entry that occurred at the same time as this reference code as the starting point for this problem.


9030 Array no longer protected due to missing or failed disk unit

Perform IOPIP21.

9031 Automatic rebuild initiated for array

Either a previous rebuild was interrupted and was automatically restarted, or a hot spare disk unit was used to automatically rebuild the array. Look for other reference codes and take action on them.


9040 Array protection temporarily suspended

No action required. Protection will be automatically restarted.


9041 Background array parity check detected and corrected errors

Call your next level of support to report the problem.

9050 Required cache data cannot be located for a disk unit.

Perform IOPIP30.

9051 IOP cache data exists for a missing or failed device.

If all configured units are missing, a 9054 reference code may appear in the product activity log. If so, perform the action indicated for the 9054 reference code.

Otherwise, perform IOPIP27.

9052 Cache data exists for device that has been modified.

Perform IOPIP28.

9053 IOP resources not available due to previous problems.

Take action on other IOP reference codes which have surfaced.

If you cannot get to SST or DST, and cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other IOP reference codes and take action on them.

9054 IOP resources not available due to previous problems.

Power off the system and remove all new or replacement disk units. IPL the system to DST. If you cannot perform a type A or B IPL, perform a type D IPL from removable media.

Look for Product Activity Log entries for other IOP reference codes and take action on them.

9081 I/O processor card detected device error
9082 I/O processor card detected device error

Perform IOPIP16.

9090 Disk unit has been modified after the last known status.

Re-IPL the system. If any reference codes are surfaced, go to List of system reference codes and use the new reference code as the entry point to the problem.

If you cannot resolve the problem, contact your next level of support.

9091 Incorrect hardware configuration change has been detected.

Re-IPL the system. If any reference codes are surfaced, go to List of system reference codes and use the new reference code as the entry point to the problem.

If you cannot resolve the problem, contact your next level of support.

9092 Disk unit requires initialization before use.

Perform IOPIP26.

B3B1 to B3B7 A permanent I/O processor failure occurred
B3B8 Multi-adapter bridge error detected.
B3B9 A permanent I/O processor failure occurred
B3E0 to B3E1 I/O processor detected a fault condition.
B410 to B411 A permanent I/O processor failure occurred
B412 Tape/CD or disk bus interface error occurred

Perform IOPIP16.

B935 Unknown hardware detected
BE00 I/O processor detected a fault condition.
FF3D I/O adapter detected a recoverable error
FF6D I/O processor detected a recoverable system bus error

Table 2. Failing items details

Failing Item Description Document Description
AJDG301 Vertical Licensed Internal Code Service Functions; APAR or LICTR
AJDGP01 I/O card Licensed Internal Code Service Functions; APAR or LICTR
AJDGP01 I/O processor Licensed Internal Code Service Functions; APAR or LICTR
ANYBRDG System I/O bus or any attached card See the service documentation for instructions.
ANYBUS IOP card bus error See the service documentation for instructions.
BACKPLN Card Enclosure or Planar Board See the service documentation for instructions.
CACHBAT Cache battery pack See the service documentation for instructions.
CACHE Cache adaptor card See the service documentation for instructions.
CMPRES1 Compressed device and compression IOA are not compatible See the service documentation for instructions.
CTLPNL Control panel, or the interface to the Control panel See the service documentation for instructions.
DEVBPLN Device backplane See the service documentation for instructions.
DEVTERM Terminating plug See the service documentation for instructions.
FCIOA Fibre Channel IOA See the service documentation for instructions.
IOACNFG Configuration error See the service documentation for instructions.
IOP I/O processor card See the service documentation for instructions.
MA_BRDG Multi-adapter bridge See the service documentation for instructions.
MEDIA Defective media See the service documentation for instructions.
OPT_CLN Fiber optic cleaning kit See the service documentation for instructions.
PCIBUS Any PCI card on the PCI bus See the service documentation for instructions.
STORIOA Storage I/O adapter See the service documentation for instructions.
SVCDOCS Customer engineer directed to system problem analysis See the service documentation for instructions.
USER System Operator/User See the service documentation for instructions.