IBM Support

WMS 9.1 pipelines missing after upgrading from 9.1 to 9.5

Troubleshooting


Problem

WMS pipelines missing after upgrading from 9.1  to 9.5

Symptom

  1. YFS_PIPELINE table do not have entries related to WMS-91
  2. Below error thrown while confirming a draft order
    • YFS10297: YFS: No Pipeline is configured. [PipelineKey:WMS-Purchase-91]

Cause

Some factory setup data got deleted during upgrade to 9.5.  Product team may change/delete the factory setup data during upgrade. It is advised that clients should not make use of the OOB pipelines in their implementation. Rather client should  make a copy of these pipelines and edit as required and use it for their implementation to avoid these kind of issues. As a work around you may reload the deleted factory setup data.

Resolving The Problem

  1. Take a copy of the fc_migrator.xml, save as fc_migrator_fix.xml , from <95_INSTALL_DIR>/Migration/9.1/database/FactorySetup/XMLS
  2. Comment the sections related to added and changed (keep only deleted) 
  3. Update DeleteEntity="N" for all the entries in fc_migrator_fix.xml
  4. Change directory to <95_INSTALL_DIR>/Migration/9.1/
  5. Execute <95_INSTALL_DIR>/bin>loadDefaults.cmd/.sh <95_INSTALL_DIR>/Migration/9.1/database/FactorySetup/XMLS/fc_migrator_fix.xml
  6. Restart the application server and rerun the scenario

 

Document Location

Worldwide

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS6PEW","label":"Sterling Order Management"},"Component":"","Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.5","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]