Troubleshooting
Problem
Running WASPreUpgrade and it fails with MIGR0272E: The migration function cannot complete the command.
Symptom
The command exits with MIGR0272E: The migration function cannot complete the command.
Trace shows: UpgradeBase > handleException Entry
com.ibm.wsspi.migration.document.exceptions.NotFoundException:
at com.ibm.ws.migration.document.BasicDocumentCollection.getChild(BasicDocumentCollection.java:465)
at com.ibm.ws.migration.utility.ProfileImpl.initializeOwningValues(ProfileImpl.java:355)
at com.ibm.ws.migration.utility.ProfileImpl.<init>(ProfileImpl.java:139)
Cause
Multiple copies of setupCmdLine script exist in the same directory with different extensions. The migration script checks for all of those files and it fails when the files contain node name or cell name that is different from the current one in the config.
Diagnosing The Problem
Search for multiple copies of setupCmdLine in the same directory with different extensions.
Resolving The Problem
Delete or move the invalid setupCmdLine files out of WebSphere directories, and only keep the one copy with current information.
Was this topic helpful?
Document Information
Modified date:
15 June 2018
UID