IBM Support

VIOS error from physical NPIV FC adapter: FCA_ERR6 with error code "0000 0E6C"

Troubleshooting


Problem

Virtual FC client adapter on IBM i client is in inoperative state or LPM validation fails.

Symptom

A) Virtual FC client adapter on IBM i client is in inoperative state.
C) On the Virtual I/O Server side:
     1) The corresponding virtual FC server adapter (vfchost) status is "NOT_LOGGED_IN".
     2) The physical FC adapter mapped to the vfchost is logging FCA_ERR6 errors.
     3) Other clients that use the same physical NPIV port (FC name:fcs# in lsmap output) are working fine.
Sample output from Virtual I/O Server:
$ lsmap -vadapter vfchost29 -npiv
Name         Physloc                                   ClntID       ClntName             ClntOS
-----------  -------------------------------------     ---------    ---------------      -----------
vfchost29    U9009.42A.7830580-V2-C204                 18                
 
Status:NOT_LOGGED_IN
FC name:fcs4                   FC loc code:U78D2.001.WZS0449-P1-C9-T1
Ports logged in:0
Flags:4<NOT_LOGGED>
VFC client name:               VFC client DRC:
$ errlog -ls|tee errlog.out
$ vi errlog.out               ->search for FCA_ERR6 error
...
LABEL:		FCA_ERR6
IDENTIFIER:	ECCE4018

Date/Time:       Wed Feb 26 15:56:56 2020
Sequence Number: 1768312
Machine Id:      00C305804B00
Node Id:         <VIOS>
Class:           S
Type:            TEMP
WPAR:            Global
Resource Name:   fcs4

Description
SOFTWARE PROGRAM ERROR

	Recommended Actions
	PERFORM PROBLEM DETERMINATION PROCEDURES

Detail Data
SENSE DATA
0000 0020 0000 0E6C 0002 0102 48E4 471D 005C F7A2 00C8 1F00 1000 0010 9B5C 9567  [... ...l....H.G..\...........\.g]
0000 0000 0000 0071 0000 0000 0000 01EF F001 0080 00FF FFFE 0000 0000 0000 0000  [.......q........................]
0000 0001 0000 0003 0000 0000 0000 0000 0000 0090 0000 0000 0000 0000 0000 0000  [................................]
0000 012C 0000 0000 0000 0000 0000 0000 0000 000A 0000 07D0 0000 0064 0000 000F  [...,.......................d....]
0004 0000 7A1B 894C 000C 0100 0C00 0C00 0001 0006 0000 0100 0000 0000 0000 0000  [....z..L........................]
0000 0058 0000 0046 0000 0667 4700 6806 0000 0000 0000 0000 C050 760A D63A 00BC  [...X...F...gG.h..........Pv..:..]
0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000  [................................]
0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000  [................................]
0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000  [................................]
0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000  [................................]
0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000  [................................]
0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000  [................................]
5100 0000 0100 0000 0000 004F 1500 0301 0500 147F 0000 0001 636D 4643 00FF FFFE  [Q..........O............cmFC....]
0000 0000 0000 0000 0000 0000 0000 0000 F100 0C02 3056 3800 0000 0000 0000 0000  [....................0V8.........]
F100 0C01 C491 0000 F100 0C01 C491 0074 0800 0000 21B0 0000 0800 0000 21B0 0074  [...............t....!.......!..t]
0000 0074 0000 0074 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000  [...t...t........................]
0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0100 0602 0000 0018  [................................]
7A1B 894C 7A1B 9504 0300 8410 6806 0000 0000 0667 FFFF FFFF 0000 0000 0000 0000  [z..Lz.......h......g............]
0000 0000 0000 0000 0000 0000 0000 0000 FFFF FFFF 0000 0000 0000 0000 018A 0404  [................................]
0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000  [................................]
5100 0000 0908 0028 8000 0800 00FF FFFF 0000 07D0 C050 760A D63A 00BC C050 760A  [Q......(.............Pv..:...Pv.]
7400 0000 0000 B021 0000 0008 7400 0000 0000 0001 FEFF FF00 B902 4700 048A 0A14  [t......!....t.............G.....]
0000 0000 147F 6806 00EA 1000 2D00 FFFF 7400 0000 7400 B021 0000 0008 7400 0000  [......h.....-...t...t..!....t...]
0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000  [................................]
0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000  [................................]
0009 147F 0000 0000 0000 0500 0000 0180 0000 0000 0000 0000 0000 0000 0000 0000  [................................]
0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000  [................................]
0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000  [................................]
0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000  [................................]
0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000  [................................]
0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000  [................................]
0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000  [................................]

Environment

VIOS 3.1
Client OS: IBM i or AIX

Diagnosing The Problem

You can download the summ utility available at IBM AIX Support Center Tools to decode the FCA_ERR6 error, and install it on an AIX host or Virtual I/O Server from the oem_setup_env shell.
The decoding translates to something like this:
Feb 26 15:56:56 fcs4      T FCA_ERR6           FDISC failed during NPIV setup for C05XXXXXXXXX00BC
Notice the client's virtual WWPN is included

Resolving The Problem

From the Detail Data, the error code is "0000 0E6C" indicates the NPIV client requested a Re-login to the fabric (FDISC) and that failed.
When a physical adapter logs in to the switch, it does a FLOGI first.
However, when a virtual adapter logs in to the switch, it does a FDISC. In this case, FDISC is not working for the virtual adapter. This error is logged when we receive an LS_RJT (Link Service Reject) for this FDISC (Discover Fabric Service Parameters), and this error indicates the switch was unable to perform this request.
The error is coming from the SAN switch.
Contact your local SAN Switch Support Representative to review the switch port configuration for the virtual WWPN in question.