Problem

Unable to start IBM Planning Analytics Spreadsheet Services and IBM Cognos TM1 service in parallel on the same host server.

Symptom

  • IBM Cognos TM1 service and IBM Planning Analytics Spreadsheet service fail to run in parallel while configured on the same host server.
  • IBM Planning Analytics Spreadsheet service runs without any issues when IBM Cognos TM1 service is in stopped state and vice-versa.

Cause

The issue experienced is likely due to a port conflict.  Please ensure that each application is configured to use unique ports.

Resolving The Problem

  • IBM Planning Analytics Spreadsheet services uses port 9510 by default hence ensure that IBM Cognos TM1 service is configured to run using different port number.
    • The port number for IBM Cognos TM1 service can be changed using IBM Cognos Configuration.
  • The jvm.options for IBM Cognos TM1 service (tm1_64\wlp\usr\servers\tm1\) and IBM Planning Analytics Spreadsheet services (tm1web\wlp\usr\servers\tm1web\) may contain additional port assignments, for example: -Dcom.sun.management.jmxremote.port=7999
    • Any port assignments must use ports that are not used by any other application

Document Location

Worldwide

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSCTEW","label":"IBM Planning Analytics Local"},"ARM Category":[{"code":"a8m50000000KzJJAA0","label":"Installation and Configuration->TM1 Web"}],"ARM Case Number":"TS004001346","Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"All Version(s)","Line of Business":{"code":"LOB10","label":"Data and AI"}}]