What is a POST error code?

POST numeric error codes are errors that occur during system bootup. If you have recently added, moved, or removed options within your system:

Troubleshooting steps
  1. Boot the system and take note of the POST error code you are receiving.

  2. Lookup the POST error code in the table below. Troubleshoot or run diagnostics on the components indicated.

    Troubleshoot IntelliStation components
    Download diagnostics

    Note: Some parts may need replacement by an IBM Authorized Service Technician. Contact your local IBM Support Center.

The following error messages can occur when you are booting your system. In the following index, "X" can represent any number. The Component(s) column will tell you which component to troubleshoot, or which part might possibly need replacement.

POST error code
Component(s) to troubleshoot or replace
000 SCSI Adapter not enabled.

Verify adapter device and Bus Master fields are enabled in the PCI configuration program. See documentation shipped with computer.

02X (e.g. 020-029)
SCSI Adapter
08X Check SCSI terminator installation.
1. SCSI Cable
2. SCSI Terminator
3. SCSI Device
4. SCSI Adapter
101 System board interrupt failure.
System Board
102 System board timer error.
System Board
106
System Board
110 System board memory parity error.
1. Memory Module
2. System Board
111 I/O channel parity error.
1. Reseat adapters
2. Any Adapter
3. System Board
114 Adapter ROM error.
1. Adapter Memory
2. System Board
129 Internal cache test error.
1. Processor
2. L2 Cache Memory
3. System Board
151 Real-time clock failure.
System Board
161 Bad CMOS battery.
1. Run Setup
2. CMOS Backup Battery
3. System Board
162 Configuration mismatch.
1. Run Setup and verify Configuration
2. Had a device been added, removed, changed location? If not, suspect that device
3. Power-on external devices first, then power-on computer
4. CMOS Backup Battery
5. System Board
162 And unable to run diagnostics.
1. Diskette Drive
2. System Board
3. Diskette Drive Cable
163 Clock not updating or invalid time set.
1. Set the Time and Date in F1 CMOS setup
2. CMOS Backup Battery
3. System Board
164 POST detected a base memory or extended memory size mismatch error.
1. Run F1 Setup. Check System Summary menu for memory size change.
2. Run the Extended Memory Diagnostic tests.
166 Boot Block Check Sum Error
1. Run Flash Recovery using Boot Block. Use "Flash recovery boot block jumper"
2. System Board
167 Microprocessor installed that is not supported by the current POST/BIOS.
1. Run Setup. Check Stepping level for the BIOS level needed, then perform the flash update.
2. Processor
168 Alert on LAN error
1. Run Setup. Check to see that Ethernet and Alert on LAN are enabled.
2. System Board
17X, 18X
C2 Security
175
1. Run Configuration via the F1 Setup Utility program
2. System Board
176
Covers were removed from the computer.
177 Corrupted Administrator Password.
System Board
178
System Board
183
Enter the administrator password
184 Password removed due to check-sum error.
Enter new password
185 Corrupted boot sequence.
Set configuration and reinstall the boot sequence.
186
System Board
187
1. Clear Administration password
2. System Board
189
More than three password attempts were made to access the computer.
190 Chassis intrusion detector was cleared. This is information only, no action required. If this code does not clear:
System Board
1XX Not listed above.
System Board
201,20X Memory data error.
1. Run Enhanced Diag. Memory Test
2. Memory Module
3. System Board
225
Unsupported Memory
229 External cache test error.
1. L2 Cache Memory
2. System Board
262 POST detected a base memory or extended memory type error.
1. Run F1 Setup. Check System Summary menu for memory type change.
2. Run the Extended Memory Diagnostic tests.
301
1. Keyboard
2. Keyboard Cable
3. System Board
303 With an 8603 error.
1. Mouse
2. Keyboard
3. Keyboard Cable
4. System Board
303 With no 8603 error.
1. Keyboard
2. Keyboard Cable
3. System Board
3XX Not listed above.
1. Keyboard
2. Keyboard Cable
3. System Board
5XX
1. Video Adapter (if installed)
2. System Board
601
1. Diskette Drive A
2. Diskette Drive Cable
3. System Board
602
1. Bad Diskette ?
2. Verify Diskette and retry.
604 And able to run diagnostics.
1. Run Setup and verify diskette configuration settings
2. Diskette Drive A/B
3. Diskette Drive Cable
4. System Board
605 POST cannot unlock the diskette drive.
1. Diskette Drive
2. Diskette Drive Cable
3. System Board
662
Diskette drive configuration error or wrong diskette drive type, run Setup Configuration.
6XX Not listed above.
1. Diskette Drive
2. System Board
3. External Drive Adapter
4. Diskette Drive Cable
5. Power Supply
762 Math coprocessor configuration error.
1. Run Setup
2. Processor
3. System Board
7XX Not listed above.
1. Processor
2. System Board
962 Parallel port configuration error.
1. Run Configuration
2. Parallel Adapter (if installed)
3. System Board
9XX
1. Printer
2. System Board
1047
16-Bit AT Past SCSI Adapter
107X Check SCSI terminator installation.
1. Check SCSI terminator installation.
2. SCSI Cable
3. SCSI Terminator
4. SCSI Device
5. SCSI Adapter
1101 Serial connector error, possible system board failure.
Run Enhanced Diagnostics
1101,1102,1106, 1108,1109
1. System Board
2. Any Serial Device
1107
1. Communications Cable
2. System Board
1102 Card selected feedback error.
Run Enhanced Diagnostics
1103 Port fails register check.
1. Run Enhanced Diagnostics
2. System Board
1106 Serial option cannot be turned off.
1. Run Enhanced Diagnostics
2. System Board
1107
1. Serial Device Cable
2. System Board
1110 Register test failed.
1. Run Enhanced Diagnostics
2. System Board
1116 Interrupt error.
Run Enhanced Diagnostics
1117 Failed baud rate test.
Run Enhanced Diagnostics
1162 Serial port configuration error.
1. Run Configuration
2. Serial Adapter (if installed)
3. System Board
11XX Not listed above.
System Board
1201
1. System Board
2. Any Serial Device
1202.1206,1208, 1209,12XX
1. Dual Async Adapter/A
2. System Board
3. Any Serial Device
1207
1. Communications Cable
2. Dual Async Adapter/A
13XX
Game Adapter
1402 Printer not ready.
Information only
1403 No paper error, or interrupt failure.
Information only
1404 System board timeout failure.
Run Enhanced Diagnostics
1405 Parallel adapter error.
Run Enhanced Diagnostics
1406 Presence test error.
Run Enhanced Diagnostics
14XX Not listed above. Check printer before replacing system board.
1. Printer
2. System Board
15XX
SDL.C Adapter
1692 Boot sequence error.
Run FDISK to ensure at least one active partition is set active.
16XX
36/38 Workstation Adapter
1762 Harddisk drive configuration error,
Run Configuration via the F1 Setup Utility program
1780 (Disk Drive 0) 1781 (Disk Drive 1) 1782 (Disk Drive 2) 1783 (Disk Drive 3)
1. Power Supply
2. Hard Disk Drive
3. System Board
4. Hard Disk Cable
180X, 188X PCI configuration or resource error.
1. Run Setup and verily PCI/ISA configuration settings.
2. If necessary, set ISA adapters to "Not available" to allow PCI adapters to properly configure.
3. Remove any suspect ISA adapters.
4. Rerun diagnostics.
5. PCI Adapter
1962 Boot sequence error.
Possible hard disk drive problem
209X
1. Diskette Drive
2. Diskette Cable
3. 16-bit AT Fast SCSI Adapter
20XX Not listed above
BSC Adapter
21XX
1. SCSI Device
2. 16-bit AT Fast SCSI Adapter
3. Alternate BSC Adapter
2401,2402 If screen colors change.
Display
2401,2402 If screen colors are OK.
1. System Board
2. Display
2409
Display
2410
1. System Board
2. Display
2462 Video memory configuration error.
1. Check cable connections.
2. Run Setup and verify video configuration settings.
3. Video Memory Modules
4. Video Adapter (if installed)
5. System Board
3015,3040 Check for missing wrap or terminator plug on the adapter.
1. Network Attached?
2. LF Translator
3. Cable Problem
4. PC Network Adapter
30XX
1. PC Network Adapter
2. LF Translator
3. Cable Problem?
3115,3140
1. Network Attached?
2. LF Translator
3. Alternate PC Network-Adapter
4. Cable Problem
31XX
1. Alternate PC Network Adapter
2. LF Translator
3. Cable Problem
36XX
GPIB Adapter
38XX
DAC Adapter
4611.4630
1. Multiport/2 Interface Board
2. Multiport/2 Adapter
4612,4613 4640,4641
1. Memory Module Package
2. Multiport/2 Adapter
4650
Multiport Interface Cable
46XX No) listed above.
1. Multiport/2 Adapter
2. Multiport/2 Interface Board
3. Memory Module
5600
Financial System Controller Adapter
5962 An IDE device (other than hard drive) configuration error.
1. Run Configuration
2. CD-ROM Drive
3. CD-ROM Adapter
4. ZIP or other ATAPI device
5. System Board
62XX
1. 1st Store Loop Adapter
2. Adapter Cable
63XX
1. 2nd Store Loop Adapter
2. Adapter Cable
64XX
Network Adapter
71XX
Voice Adapter
74XX
Video Adapter (if installed)
76XX
Page Printer Adapter
78XX
High Speed Adapter
79XX
3117 Adapter
80XX
PCMCIA Adapter
84XX
1. Speech Adapter
2.Speech ControlAssy.
8601,8602
1. Pointing Device (Mouse)
2. System Board
8603,8604
1. System Board
2. Pointing Device (Mouse)
86XX Not listed above
1. Mouse
2. System Board
89XX
1. PC Music Adapter
2. MIDI Adapter Unit
91XX
1. Optical Drive
2. Adapter
96XX
1. SCSI Adapter
2. Any SCSI Device
3. System Board
10101,10102,10104 10105,10106,10107 10108,10109,10111 10112,10113,10114 10115,10116
1. Have customer verify correct operating system device drivers are installed and operational.
2. Modem
10103,10110,101171
1. System Board
2. Data/Fax Modem
10117 Not listed above.
1. Check system speaker
2. Check PSTN cable
3. External DAA (if installed)
4. Modem
10118
1. Run Diagnostics and verify the correct operation of the modem slot
2. Modem
10119
1. Diagnostics detected a non-IBM modem
2. Modem
10120
1. Check PSTN Cable
2. External DAA (if installed)
3. Modem
10132,10133.10134 10135,10136,10137 10138,10139,10140 10141,10142,10143 10144.10145,10146 10147,10148,10149 10150,10151,10152
Modem
10153
1. Data/Fax Modem
2. System Board
101XX Not listed above.
1. Modem Adapter/A
2. Data/Fax Modem
3. System Board
10450,10451,10490 10491,10492,10499 Read/Write error.
1. Run Enhanced Diagnostics
2. Hard Disk Drive
3. System Board
10452 Seek test error.
Run Enhanced Diagnostics
10453 Wrong drive type?
Information only
10454 Sector buffer test error.
Run Enhanced Diagnostics
10455,10456 Controller error.
Run Enhanced Diagnostics
10459 Drive diagnostic command error.
Information only
10461 Drive format error
Run Enhanced Diagnostics
10462 Controller seek error.
Run Enhanced Diagnostics
10464 Hard Drive read error.
Run Enhanced Diagnostics
10467 Drive non fatal seek error.
Run Enhanced Diagnostics
10468 Drive fatal seek error.
Run Enhanced Diagnostics
10469 Drive soft error count exceeded.
Run Enhanced Diagnostics
10470,10471,10472 Controller wrap error.
Run Enhanced Diagnostics
10473 Corrupt data. Low level format might be required.
Information only
10480
1. Hard Disk Drive (ESDI)
2. Drive Cable
3. System Board
10481 ESDI drive D seek error.
Run Enhanced Diagnostics
10482 Drive select acknowledgement bad.
Run Enhanced Diagnostics
106X1
1. Check Configuration
2. Ethernet Adapter
10635
1. Power-off computer, wait ten seconds; then power-on the computer.
2. Ethernet Adapter
10651,10660
1. Check Cables
2. Ethernet Adapter
106XX Not listed above.
Ethernet Adapter
107XX
1. 5.25-inch External Diskette Drive
2. 5.25-inch Diskette Drive Adapter/A
109XX Check the adapter cables.
1. ActionMedia Adapter/A
2. System Board
112XX This adapter does not have cache.
1. SCSI Adapter
2. Any SCSI Device
3. System Board
119XX
3119 Adapter
121XX
1. Modem Adapter
2. Any Serial Device
3. System Board
136XX
1. ISDN Primary Rate Adapter
2. System Board
137XX
System Board
141XX
Realtime Interface Coprocessor Portmaster Adapter/A
143XX
1. Japanese Display Adapter
2. System Board
14710,14711
1. System Board Video Adapter
2. Adapter Video Memory
148XX
Video Adapter
14901.14902 1491X, 14922
1. Video Adapter (if installed)
2. System Board
3. Display (any type)
14932
1. External Display
2. Video Adapter
161XX
FaxConcentrator Adapter
164XX
1. 120 MB Internal Tape Drive
2. Diskette Cable
3. System Board
16500
6157 Tape Attachment Adapter
16520,16540
1. 6157 Streaming Tape Drive
2. 6157 Tape Attachment Adapter
166XX, 167XX
1. Token Ring Adapter
2. System Board
18001 to 18029
1. Wizard Adapter
2. Wizard Adapter Memory
18031 to 18039
Wizard Adapter Cable
185XXXX
1. DBCS Japanese Display Adapter/A
2. System Board
20001 to 20003
1. Image Adapter/A Image-1 Adapter/A
2. Memory Module DRAM, VRAM
20004
1. Memory Module DRAM, VRAM
2. Image Adapter/A Image-1 Adapter/A
20005 to 20010
1. Image Adapter/A Image-1 Adapter/A
2. Memory Module DRAM, VRAM
200XX Not listed above.
1. Image Adapter/A Image-1 Adapter/A
2. Memory Module DRAM, VRAM
3. System Board
20101 to 20103
1. Printer/Scanner Option
2. Image Adapter/A
3. Memory Module DRAM, VRAM
20104
1. Memory Module DRAM, VRAM
2. Printer/Scanner Option
3. Image Adapter/A
20105 to 20110
1. Printer/Scanner Option
2. Image Adapter/A
3. Memory Module DRAM, VRAM
Image Adapter/A Memory Test Mure indicated by graphic of adapter.
Replace memory module
206XX
1. SCSI-2 Adapter
2. Any SCSI Device
3. System Board
208XX Verify there are no duplicate SCSI ID settings on the same bus.
Any SCSI Device
210XXXX Internal bus, size unknown. 210XXX1 External bus, size unknown.
1. SCSI Hard Disk Drive
2. SCSI Adapter or System Board
3. SCSI Cable
4. SCSI ID Switch (on some models)
Tape Drive ambLED remains on.
1. Tape Drive
2. SCSI Cable (internal)
3. SCSI Adapter or System Board
Tape Drive green "in use" LED fails to come on.
1. Tape Drive
2. SCSI Adapter or System Board
3. SCSI Cable (internal) SCSI Cable (external)
Tape automatically ejected tron) drive.
1. Tape Cassette
2. Drive
SCSI ID on rotary switch does not match SCSI ID set in configuration. Verify drive switches inside cover are set to zero.
1. Rotary Switch Circuit Board
2. Circuit Board Cable
3. Tape Drive
Tape sticks/breaks in drive. Verify that the tapes used meet ANSI standard X3B5.
Tape Cassette
212XX
1. SCSI Printer
2. Printer Cable
213XX
SCSI Processor
214XX
WORM Drive
215XXXC 215XXXD 215XXXE 215XXXU If an external device, and power-on LED is off, check external voltages.
1. CD-ROM Drivel CD-ROM Drive 11 Enhanced CD-ROM Drive 11 Any CD-ROM Drive
2. SCSI Cable
3. SCSI Adapter or System Board
216XX
Scanner
217XX If an external device, and power-on LED is off, check external voltages.
1. Rewritable Optical Drive
2. SCSI Adapter or System Board
3. SCSI Cable
218XX Check for multi CD tray, or juke box.
Changer
219XX
SCSI Communications Device
24201YO, 2421 OYO Be sure wrap plug is attached.
1. ISDN/2 Adapter
2. ISDN/2 Wrap Plug
3. ISDN/2 Communications Cable
273XX
1 Mbps Micro Channel Infrared LAN Adapter
27501,27503 27506,27507
1. ServerGuard Adapter
2. System Board
27502,27504,27510 27511,27533,27534 27536,27537
ServerGuard Adapter
27509
Remove redundant adapters, run Auto Configuration program, then retest.
27512
1. WMSELF.DGS diagnostics tile missing.
2. WMSELF.DGS diagnostics file incorrect.
27535
1. 3V Lithium Backup Battery
2. ServerGuard Adapter
27554
1. Internal Temperature out of range
2. ServerGuard Adapter
27555,27556
1. ServerGuard Adapter
2. Power Supply
27557
1. 7.2V NICad Main Battery Pack
2. ServerGuard Adapter
27558,27559 27560,27561
1. PCMCIA Type 11 Modem
2. ServerGuard Adapter
27562
1. External Power Control not connected
2. External Power Control
3. ServerGuard Adapter
27563,27564
1. External Power Control
2. ServerGuard Adapter
275XX
Update Diagnostic Software
2780110 27879
1. Personal Dictation System Adapter
2. System Board
27880 to 27889
External FRU (Speaker, Microphone)
1999030X Hard disk reset failure.
Possible hard disk drive problem.

 

Back to top


Need more help?
Please select one of the the following options for further assistance:

//www.ibm.com/i/v14/icons/fw.gif Support forums
//www.ibm.com/i/v14/icons/fw.gif Submit a technical question
Before you call IBM Service

 

Document Location

Worldwide

Operating System

IntelliStation Pro:All operating systems listed

[{"Type":"HW","Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"HWP01","label":"IntelliStation Pro->IntelliStation M Pro"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"HWP02","label":"IntelliStation Pro->IntelliStation Z Pro"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"HWP03","label":"IntelliStation Pro->IntelliStation E Pro"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"HWP05","label":"IntelliStation Pro->IntelliStation A Pro"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"HWP99","label":"IntelliStation Pro->IntelliStation R Pro"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
28 January 2019

UID

ibm1MIGR-4BAHK2