VIOS 4.1.0.21 Release Notes

Package Information

PACKAGE: Update Release 4.1.0.21
IOSLEVEL: 4.1.0.21

VIOS level is

The AIX level of the NIM Master level must be equal to or higher than

Update Release 4.1.0.21

AIX 7300-02-02

General package notes

Be sure to heed all minimum space requirements before installing.

Review the list of fixes included in Update Release 4.1.0.21

To take full advantage of all the functions available in the VIOS, it may be necessary to be at the latest system firmware level. If a system firmware update is necessary, it is recommended that the firmware be updated before you update the VIOS to Update Release 4.1.0.21.

Microcode or system firmware downloads for Power Systems

If the VIOS being updated has filesets installed from the VIOS Expansion Pack, be sure to update those filesets with the latest VIOS Expansion Pack if updates are available.

Update Release 4.1.0.21 updates your VIOS partition to ioslevel 4.1.0.21. To determine if Update Release 4.1.0.21 is already installed, run the following command from the VIOS command line.

$ ioslevel

If Update Release 4.1.0.21 is installed, the command output is 4.1.0.21.

Note: The VIOS installation DVDs and the level of VIOS preinstalled on new systems might not contain the latest fixes available. It’s highly recommended that customers that get the physical GA level (i.e., 4.1.0.00) to update to the electronic GA levels (i.e., 4.1.0.21) as soon as possible. Missing fixes might be critical to the proper operation of your system. Update these systems to a current service pack level from Fix Central.

Upgrade to VIOS 4.1.x

·       Existing VIOS systems with supported versions of 3.1.x.y can be upgraded to VIOS version 4.1.0.00 (DVD image) or 4.1.0.21 (Flash image) using viosupgrade tool . Although it is recommended to be on VIOS 3.1.4.30 or later SP level before upgrading to VIOS 4.1.x level.

 

·       VIOS systems with SSP configuration must be on 3.1.3.x or later level before upgrading to 4.1.x level or adding 4.1.x nodes into cluster.

 

·       If Active Memory Sharing (AMS) is configured on the VIOS, it should be un-configured before upgrading. You may refer the link on how to un-configure.

 

·       Before upgrading, you may read the viosupgrade blog in PowerVM Community which explains various scenarios.

 

·       After an upgrade to VIOS 4.1.0.0 or VIOS 4.1.0.21, the padmin user may be unable to login due to premature password expiration. Before running viosupgrade user should apply the ifix to avoid the issue. Please refer the support document for more details.

 

For Customers using NVMe Over Fabric (SAN) as their Boot Disk

 

Booting from NVMeoF disk may fail if certain fabric errors are returned, hence a boot disk set up with multiple paths is recommended.  In case there is a failure to boot, the boot process may continue if you exit from the SMS menu. Another potential workaround is to discover boot LUNs from the SMS menu and then retry boot.

 



Note

 

If the Virtual I/O servers are installed on POWER10 systems and configured with “32Gb PCIe4 2-Port FC Adapter, Feature Code(s) EN1J and EN1K”, then the requirement is to update the adapter microcode level to 7710812214105106.070115 before updating the Virtual I/O server to 4.1.0.21 level.

 

Please refer to the release notes at this link

 

4.1.0.21 New Features

VIOS 4.1.0.21 adds the following new features:

 

Security enhancements

·       Supports Trusted Execution, Trusted Update and Secure Boot.

·       Supports new stronger default password (SSHA-256) and out of the box long password support (255 character limit)

·       Data protection with LVM encryption for rootvg and dump devices.       

·       Services that are not secure like rexec, rsh are removed. Telnet / ftp service are disabled. Users can enable telnet / ftp service if required.

·       ksh93 is used as the default ksh in VIOS commands and scripts

 

viosupgrade enhancements

 

The major enhancements done in viosupgrade in this release are as follows.

·       Added new option -F devname to preserve the device names for vfchost adapter devices, fcnvme, nvme, fscsi, iSCSI devices and network adapter devices.

·       The new options “-k” and “-o rerun” is added which is specific to pre-restore script execution.

 

viosbr enhancements

 

Restore of all the PV backed VTDs if the same PV is mapped to multiple vhosts.

 

Others

 

Enhancement in alt_root_vg command, to run it in phases. This enhancement allows the alt_root_vg command to separate the cloning phase from the update phase.

Hardware Requirements

Please check this link for supported hardware.

Known Capabilities and Limitations

The following requirements and limitations apply to Shared Storage Pool (SSP) features and any associated virtual storage enhancements.

Requirements for Shared Storage Pool

 

Limitations for Shared Storage Pool

Software Installation

SSP Configuration

Feature

Min

Max

Number of VIOS Nodes in Cluster

1

16*

Number of Physical Disks in Pool

1

1024

Number of Virtual Disks (LUs) Mappings in Pool

1

8192

Number of Client LPARs per VIOS node

1

250*

Capacity of Physical Disks in Pool

10GB

16TB

Storage Capacity of Storage Pool

10GB

512TB

Capacity of a Virtual Disk (LU) in Pool

1GB

4TB

Number of Repository Disks

1

1

Capacity of Repository Disk

10GB

1016GB

Number of Client LPARs per Cluster

1

2000

 

*Support for additional VIOS Nodes and LPAR Mappings:

Prerequisites for expanded support:

Here are the new maximum values for each of these configuration options, if the associated hardware specification has been met:

Feature

Default Max

High Spec Max

Number of VIOS Nodes in Cluster

16

24

Number of Client LPARs per VIOS node

250

400

 

Other notes:


Network Configuration


Storage Configuration


Shared Storage Pool capabilities and limitations

Installation Information

Pre-installation Information and Instructions

Please ensure that your rootvg contains at least 30 GB and that there is at least 4GB free space before you attempt to update to Update Release 4.1.0.21. Run the lsvg rootvg command, and then ensure there is enough free space.

Example: 

$ lsvg rootvg 
 
 
 
VOLUME GROUP:       
rootvg                   
VG IDENTIFIER:  
00f6004600004c000000014306a3db3d
VG STATE:
active     
PP SIZE:
64 megabyte(s)
VG PERMISSION:            
read/write               
TOTAL PPs:
511 (32704 megabytes)
MAX LVs:                   
256                      
FREE PPs:
64 (4096 megabytes)
LVs:                       
14                       
USED PPs:
447 (28608 megabytes)
OPEN LVs:                    
12 
QUORUM:
2 (Enabled)
TOTAL PVs:                                  
1
VG DESCRIPTORS:
2
STALE PVs:                                  
0
STALE PPs: 
0
ACTIVE PVs:                                         
1
AUTO ON:
yes
MAX PPs per VG:     
32512                                     
 
 
MAX PPs per PV:     
1016 
MAX PVs:
32
LTG size (Dynamic):                
256 kilobyte(s)
AUTO SYNC:
no
HOT SPARE:                
no                       
BB POLICY:
relocatable
PV RESTRICTION:     
none                     
INFINITE RETRY:
no
 

VIOS upgrades with Third Party Software

When the user upgrades from 3.1.x.y to 4.1.0.00 level and above, third-party software is not packaged with the IBM supplied mksysb image. User needs to install the respective third-party software after the upgrade is complete and run viosupgrade -o rerun to restore the respective devices.

 

 

Updating from VIOS version 4.1.0.00

 

VIOS Update Release 4.1.0.21 may be applied directly to any VIOS at level 4.1.0.00.

 

Before installing the VIOS Update Release 4.1.0.21

 

Warning: The update may fail if there is a loaded media repository.

 

Instructions: Checking for a loaded media repository

 

To check for a loaded media repository, and then unload it, follow these steps.

 

1.     To check for loaded images, run the following command:

$ lsvopt 
The Media column lists any loaded media.

 

2.     To unload media images, run the following commands on all Virtual Target Devices that have loaded images.

$ unloadopt -vtd <file-backed_virtual_optical_device >

 

3.     To verify that all media are unloaded, run the following command again.

$ lsvopt 
The command output should show No Media for all VTDs.



Instructions: Migrate Shared Storage Pool Configuration

 

The Virtual I/O Server (VIOS) Version 3.1.x.y or later, supports rolling updates to release 4.1.0.21 for SSP clusters.

 

The rolling updates enhancement allows the user to apply Update Release 4.1.0.21 to the VIOS logical partitions in the cluster individually without causing an outage in the entire cluster. The updated VIOS logical partitions cannot use the new SSP capabilities until all VIOS logical partitions in the cluster are updated.

 

To upgrade the VIOS logical partitions to use the new SSP capabilities, ensure that the following conditions are met:

 

·        All VIOS logical partitions must have VIOS Update Release version 3.1.x.y  or later installed.

·        All VIOS logical partitions must be running. If any VIOS logical partition in the cluster is not running, the cluster cannot be upgraded to use the new SSP capabilities.

Instructions: Verify the cluster is running at the same level as your node.

 

1.     Run the following command:
$ cluster -status -verbose

2.     Check the Node Upgrade Status field, and you should see one of the following terms:


UP_LEVEL: This means that the software level of the logical partition is higher than the software level the cluster is running at.

ON_LEVEL: This means the software level of the logical partition and the cluster are the same.

 

Installing the Update Release

 

There is now a method to verify the VIOS update files before installation. This process requires access to openssl by the 'padmin' User, which can be accomplished by creating a link.

 

Instructions: Verifying VIOS update files.

To verify the VIOS update files, follow these steps:

1.     $ oem_setup_env

2.     Create a link to openssl if required
# 
ln -s /usr/bin/openssl /usr/ios/utils/openssl 

3.     Verify the link to openssl was created 
# 
ls -alL /usr/bin/openssl /usr/ios/utils/openssl 

4.     Verify that both files display similar owner and size 

5.     # exit

 

Use one of the following methods to install the latest VIOS Service Release. As with all maintenance, you should create a VIOS backup before making changes.

 

If you are running a Shared Storage Pool configuration, you must follow the steps in Migrate Shared Storage Pool Configuration.

 

Note: While running 'updateios' in the following steps, you may see accessauth messages, but these messages can safely be ignored.

 

 

Warning:  If VIOS rules have been deployed.


During update, there have been occasional issues with VIOS Rules files getting overwritten and/or system settings getting reset to their default values.

 

To ensure that this doesn’t affect you, we recommend making a backup of the current rules file.  This file is located here:

/home/padmin/rules/vios_current_rules.xml


First, to capture your current system settings, run this command:

$
rules -o capture

 

Then, either copy the file to a backup location, or save off a list of your current rules:

Note: The "padmin" user is restricted to redirect command output to a file, you must be in the root shell. Use "oem_setup_env" to become a root user.

 

$  oem_setup_env

# rules -o list > rules_list.txt

 

After this is complete, proceed to update as normal.  When your update is complete, check your current rules and ensure that they still match what is desired.  If not, either overwrite the original rules file with your backup, or proceed to use the ‘rules -o modify’ and/or ‘rules -o add’ commands to change the rules to match what is in your backup file.

 

Finally, if you’ve failed to back up your rules, and are not sure what the rules should be, you can deploy the recommended VIOS rules by using the following command:

$ rules -o deploy -d

 

Then, if you wish to copy these new VIOS recommended rules to your current rules file, just run:

 

$ rules -o capture

 

Note: This will overwrite any customized rules in the current rules file.

 

Applying Updates

 

Warning:

If the target node to be updated is part of a redundant VIOS pair, the VIOS partner node must be fully operational before beginning to update the target node.

 

Note:

For VIOS nodes that are part of an SSP cluster, the partner node must be shown in 'cluster -status ' output as having a cluster status of OK and a pool status of OK. If the target node is updated before its VIOS partner is fully operational, client LPARs may crash.

 

 

Instructions: Applying updates to a VIOS.

 

  1. Log in to the VIOS as the user padmin.
  2. If you use one or more File Backed Optical Media Repositories, you need to unload media images before you apply the Update Release. See details here.
  3. If you use Shared Storage Pools, then Shared Storage Pool Services must be stopped.

    $
     clstartstop -stop -n <cluster_name > -m <hostname >

  4. To apply updates from a directory on your local hard disk, follow the steps:
    1. Create a directory on the Virtual I/O Server.
      $
       mkdir <directory_name >

2.     Using ftp, transfer the update file(s) to the directory you created.

To apply updates from a remotely mounted file system, and the remote file system is to be mounted read-only, follow the steps:

      1. Mount the remote directory onto the Virtual I/O Server:
        $
         mount remote_machine_name:directory /mnt

The update release can be burned onto a CD by using the ISO image file(s). To apply updates from the CD/DVD drive, follow the steps:

      1. Place the CD-ROM into the drive assigned to VIOS.

  1. Commit previous updates by running the updateios command:
    $
     updateios -commit

  2. Verify the updates files that were copied. This step can only be performed if the link to openssl was created.
    $ 
    cp <directory_path >/ck_sum.bff /home/padmin 
    $ 
    chmod 755 </home/padmin>/ck_sum.bff 
    $ 
    ck_sum.bff <directory_path > 
    If there are missing updates or incomplete downloads, an error message is displayed.

    To see how to create a link to openssl, click
    here.

  3. Apply the update by running the updateios command
    $
     updateios -accept -install -dev <directory_name >

  4. To load all changes, reboot the VIOS as user padmin .

$ shutdown -restart

 

Note: If shutdown –restart command failed, run swrole –PAdmin for padmin to set authorization and establish access to the shutdown command properly.

  1. If cluster services were stopped in step 3, restart cluster services.

$ clstartstop -start -n <cluster_name > -m <hostname >

  1. Verify that the update was successful by checking the results of the updateios command and by running the ioslevel command, which should indicate that the ioslevel is now 4.1.0.21.

$ ioslevel

Post-installation Information and Instructions

Instructions: Checking for an incomplete installation caused by a loaded media repository.

 

After installing an Update Release, you can use this method to determine if you have encountered the problem of a loaded media library.

Check the Media Repository by running this command: 
$ 
lsrep

If the command reports: "Unable to retrieve repository data due to incomplete repository structure," then you have likely encountered this problem during the installation. The media images have not been lost and are still present in the file system of the virtual media library.

 

Running the lsvopt command should show the media images.

 

Instructions: Recovering from an incomplete installation caused by a loaded media repository.

 

To recover from this type of installation failure, unload any media repository images, and then reinstall the ios.cli.rte package. Follow these steps:

1.     Unload any media images

$ unloadopt -vtd <file-backed_virtual_optical_device>

2.     Reinstall the ios.cli.rte fileset by running the following commands.

To escape the restricted shell: 
$ 
oem_setup_env 
To install the failed fileset: 
# 
installp –Or –agX ios.cli.rte –d <device/directory > 
 To return to the restricted shell: 
# 
exit

3.     Restart the VIOS.

$ shutdown –restart

4.     Verify that the Media Repository is operational by running this command:

$ lsrep

 

Content modified in this release

ioscli snap command

 

The snap command is enhanced with -gzip option to utilise the on-chip NX GZIP accelerator for faster completion.

 

Software Updated

- python3 is included in VIOS image.

- Two versions of postgres database (version 15.3 and 13.11) are included in base image. Postgres version 13 is required to support mixed mode cluster where node versions 3.1.4.x and 4.1.0.x are part of the cluster.

 

Content removed in this release

ITM Agents software

        ITM (IBM Tivoli Monitoring) filesets are not part of VIOS 4.1.0.00 & above versions. Users need to download and install the ITM software from an external location. The ITM VIOS Premium Agent and ITM CEC Base Agent can be downloaded and installed separately as part of an updated IBM Tivoli Monitoring System P Agents 6.22 Fix Pack 4 or later bundle. Here is a link to the readme file containing information about how to obtain the image and instructions for installing.  When these agents are installed in the default directory of /opt/IBM/ITM, they can continue to utilize the cfgsvc, startsvc, and stopsvc commands to configure, start and stop the agent.

 

AMS

        Active Memory Sharing (AMS) feature is removed.

 

Software Removed

        Following filesets that are deemed not necessary are removed.

·       bos.net.tcp.rcmd, bos.net.tcp.rcmd_server (A copy is saved under: /usr/sys/inst.images/installp/ppc)

·       cas.agent tivoli.tivguid

·       rsct.opt.fence.blade rsct.opt.fence.hmc

·       sysmgt.cim.providers.metrics sysmgt.cim.providers.osbase

·       sysmgt.cim.providers.scc sysmgt.cim.providers.smash

·       sysmgt.cim.smisproviders.hba_hdr sysmgt.cim.smisproviders.hhr

·       sysmgt.cim.smisproviders.vblksrv sysmgt.cimserver.pegasus.rte

·       Java7.jre Java7.sdk Java7_64.jre Java7_64.sdk

·       itm.cec.agent itm.premium.rte itm.vios_premium.agent

·       bos.net.nfs.server devices.vdevice.IBM.vfc-client.rte

·       X11.adt.ext X11.adt.motif X11.apps.clients X11.apps.config X11.apps.custom X11.apps.msmit X11.apps.xdm

·       X11.apps.xterm X11.base.xpconfig X11.compat.adt.Motif12 X11.compat.lib.Motif10 X11.compat.lib.Motif114

·       X11.compat.lib.X11R3 X11.compat.lib.X11R4 X11.Dt.bitmaps X11.Dt.helpinfo X11.Dt.helpmin X11.Dt.helprun

·       X11.Dt.lib X11.Dt.rte X11.Dt.ToolTalk X11.fnt.coreX X11.fnt.deform_JP X11.fnt.fontServer X11.fnt.Gr_Cyr_T1

·       X11.fnt.ibm1046 X11.fnt.ibm1046_T1 X11.fnt.iso1 X11.fnt.iso2 X11.fnt.iso3 X11.fnt.iso4 X11.fnt.iso5

·       X11.fnt.iso7 X11.fnt.iso8 X11.fnt.iso8_T1 X11.fnt.iso9 X11.fnt.iso_T1 X11.fnt.ksc5601.ttf X11.fnt.ucs.cjk

·       X11.fnt.ucs.com X11.fnt.ucs.ttf_CN X11.fnt.ucs.ttf_extb X11.fnt.util X11.loc.en_US.base.lib

·       X11.loc.en_US.base.rte X11.loc.en_US.Dt.rte X11.vsm.lib

 

Fixes included in this release

The list of fixes in 4.1.0.21

 

APAR

Description

IJ41832

Install images for ICU4C.adt

IJ47909

SYSDUMPDEV: UNEXPECTED ERROR MESSAGE WITH TRADITIONAL DUMP

IJ47912

SWITCH.PRT FAILS IF THERE ARE EXISTING JOBS

IJ48461

BOS.ESAGENT UPGRADE MAY FAIL IF IBM.ESAGENT WAS ACTIVATED

IJ49130

DBN connection fails after upgrade to VIOS 4.1

IJ49273

EXPR: NOT FOUND ERRORS WHILE RESTORING MULTI VOLUME MKSYSB

IJ49274

SNMPDV3 LOGS INCORRECT MESSAGE WHEN STOPSRC IS ISSUED

IJ49275

LKU: SURROGATE CRASH IN "IN6_DELMULTI_SOURCE"

IJ49277

RESTVG WITH -R OPTION FAILS WITH OUTLINE LOGS

IJ49278

NIM MKSYSB RESTORE MAY HANG FOR ENTERPRISE_CLOUD EDITION

IJ49279

crashed at lock_free_com+000058

IJ49280

vmstat output fi/fo seems incorrect when system is in a paging

IJ49281

LPAR may crash when ipsec tunnels are created on top of vxl tunnels.

IJ49284

hmcauth command failing with c_rsh -e

IJ49285

nimadm fails for 72X "mksysb" to 73D "mksysb" migration

IJ49288

SYSTEM MAY CRASH WITH LVM SERIALIZED IO ENABLED ON LV

IJ49290

RESTORE MAY DISPLAY WRONG FILE TIMESTAMP

IJ49292

SECLDAPCLNTD NESTED GROUP HANG, CORE, OR ERRORS WITH ITDS

IJ49293

Exitstatus wasn't found in standard output

IJ49295

od -t fails with exit code zero

IJ49299

Shell returns non-zero exit status

IJ49301

PASSWORD CHANGE ATTEMPT FAILS

IJ49302

wcsxfrm_l() returns incorrect value when argument 'n' is 0

IJ49312

MLXCENTDD CRASHED AT MLXCENT_CMDQ_RESERVE_MBOX_TYPE

IJ49313

VF INTERFACE ATTACHED TO VNIC NOT REMOVED DURING LPM

IJ49315

FCSTAT OUTPUT FOR PEND_CMD'S MAY CONTINUE TO INCREMENT

IJ49316

INVALID TZ WILL CAUSE DBN ELECTION INSTABILITY

IJ49317

VIOD_BKPS DIR CONTAINS TOO MANY LOGS

IJ49320

Probable system crash in cvfsc_cmd_recv

IJ49321

Error while fetching cluster details.

IJ49322

htxcmdline -createmdt command got hung

IJ49350

Driver unrecoverable if rmdev,nddctl,entstat run in parallel

IJ49419

ALT_DISK_COPY UNFORMATTED ERRORS ON EFS MOUNT POINTS

IJ49420

Error msg handeling for Phase2/3 foralt_disk_copy.

IJ49423

SSL handshake error when using proxy server

IJ49424

INCORRECT ERROR ON LDAP USER PASSWORD CHANGE

IJ49425

SNAP COMPRESSION FAILS SILENTLY AND SNAP NOT USEABLE ON 7300-01

IJ49426

vNIC Adapter reset causes ping to fail

IJ49452

Set ANA Delay as per ANATT

IJ49486

DSI NPIV_REAL_FCSCSI_ASYNC

IJ49487

SRIOV VF Diagnostic stalled or results in failure

IJ49488

VIOS_VFC_HOST WITH ERROR NPIV_ERR_006E RC:EINVAL ALREADY STARTED

IJ49491

nim_master_recover cmd removed alt_mstr

IJ49638

COMMAND CHDEV SAVE INCORRECT IPV4 ALIAS NETMASK IN ODM

IJ49639

ERRORS IN NMON "PEAK KB/S READ+WRITE" COLUMN

IJ49640

ISSUE FACED WHILE CHANGING THE IKE ENTRIES USING SMITTY TOOL

IJ49643

MLXENTDD DRIVER IS NOT HAVING ENOUGH DMA_SIZE MEMORY

IJ49644

Microcode installation message

IJ49702

MAKE SECLDAPCLNTD SERVER CONNECTION TIMEOUT ADJUSTABLE

IJ49721

NDD_TRACE HOOKS ARE NOT CLEARED WHEN STOP IPTRACE

IJ49727

LI #OEP Bar0 changes for honouring odm configuration

IJ49740

SYSTEM CAN CRASH IN PFFINDTYPE() ON AIX 7.3 AND ABOVE

IJ49747

OFED crash in cm_alloc_response_msg() while interface detached

IJ49810

fwupdate on multipath splitter device ret wrong msg

IJ49812

CHVG -G CAN CRASH THE SYSTEM IF LVMBB IS PROCESSING ON SAME VG

IJ49830

Irrelevant command being passed to binder

IJ49831

NIM MKSYSB RESTORE HANG DUE TO DATADAEMON CORE DUMP

IJ49872

SAVEBASE MAY FAIL WITH 4K BLOCK SIZE DISK

IJ49874

Inactive LPM is failing with LU validation syst

IJ49875

rmdev may fail with ODM lock timeout error

IJ49876

nim LU hangs after completion

IJ49877

artexget may fail to collect expected tunables data

IJ49878

Update kernel copyright notice for 2024

IJ49879

NPIV CLIENT REQUESTED IMPLICIT LOGO, DRIVER SENT EXPLICIT LOGO

IJ49882

INCORRECT PRINT QUEUE STATUS SHOW

IJ49917

sscanf gives wrong output/segmentation fault.

IJ49926

LPM adapter fails after an adapter reset on VFC client.

IJ49953

A potential security issue exists

IJ49960

unamex should  be declared in sys/utsname.h

IJ49961

SECLDAPCLNTD GROUP CACHE NOT ALWAYS WORKING

IJ49962

SECLDAPCLNTD SLOW MEMORY LEAK

IJ49963

SECLDAPCLNTD GROUP CACHE IMPROVEMENT

IJ50014

LDAP SERVER MARKED DOWN DOESN'T RECOVER QUICKLY ENOUGH

IJ50015

CHDEV TO CHANGE AN SEA FAILS WITH RBAC USER

IJ50020

RXQ KPROCS CAN RUN CONTINUOUSLY DISABLED AT INTPRI3 ON SOME CPUS

IJ50047

NO -L DISPLAY WRONG VALUE

IJ50059

Crash while upgrading firmware on Mellanox network adapter

IJ50188

IO HANG IN CAVIUM FIBRE ADAPTER AFTER LINK DOWN EVENT.

IJ50217

NETISR.H INCLUDES FILE SYS/LIBSYSP.H WHICH IS NOT SHIPPED

IJ50218

/proc filesystem missing after OS migration

IJ50222

Few OFED verbs failing when RoCEv2 was enabled

IJ50223

Linker asked to preserve internal global warning from libLTO

IJ50224

PVID load up criteria missing in datadaemon

IJ50237

System crash in ras_if_gne_callback()

IJ50238

Kbd/mouse not detected with KVM switch

IJ50264

BOOT OR DUMP FAILURE ON NVME DISKS DUE TO INCORRECT FW PATH NAME

IJ50304

Verify the System Dump failing

IJ50336

NIMHTTP WITH SECURE NIMSH FAILS

IJ50341

NPIV CLIENT REQ IMPLICIT LOGO, QL DRIVER SENT EXPLICIT LOGO

IJ50359

Wrong FFC Code For an SRN-802

IJ50412

mksysb to "client" successful parallel migration gen

IJ50413

nimadm cmd help changes for bootlist and reboot flags

IJ50427

errpt while promoting data from a 4K device when it is cached.

IJ50477

MULTICAST BIND FAILS ON VLAN

IJ50478

AIXPERT COMINETDCONF SCRIPT

IJ50479

aso not disabling when updating vios 3.1.4.0 to 3.1.4.1

IJ50484

vnic kproc names should not have space characters

IJ50565

LOGINS HANG WITH TRUNCATED LASTLOG FILE

IJ50566

sysdumpdev -e hung looping in aixdiskpcmke:getPathDataSize

IJ50568

VIOS upgrade fails between major vios versions

IJ50600

syntax error on executing the

IJ50601

A potential security issue exists

IJ50605

DURING LKU RESTORATION OF THE TCPTR TABLE MAY CAUSE A HANG

IJ50657

restore memory leaks

IJ50658

KSH CAN DUMP CORE WHEN DISCONNECTING REMOTE LOGIN CONNECTION

IJ50659

Improper error msg for wrong country code

IJ50661

CONTINUOUS FCA_ERR6 0X2F AND FCA_ERR2 0X27 ERRPT ERRORS

IJ50662

Commands such as lsmpio, lspath probably will hang

IJ50744

LSPV CORE DUMPS IN ODM_GET_FIRST()

IJ50745

lldpctl add failing after removing the port from list

IJ50746

ike cmd=list db shows incorrect Remote IP Address

IJ50748

AIX NFSv4 Client to Linux NFS Server- fail to copy

IJ50750

NIM hangs even after LKU is completed successfully

IJ50754

SAVEBASE FAILS WITH 4K DISK

IJ50799

memory leak in perfstat_process api may occur in error cases.

IJ50800

ftpd behaviour is inconsistent when /etc/ftpaccess.ctl

IJ50801

GDLC IN ETHERCHANNEL ENVIRONMENT, MAY NOT WORK PROPERLY.

IJ50861

CRASH WHEN INCREASING THE MAX NUMBER OF LVS ON A SCALABLE VG

IJ50862

MKGROUP OF LOCAL GROUP DOESN'T ALLOW ADDING NIS USERS

IJ50863

DSI during varyoffvg when space reclamation is in progress.

IJ50968

SNAP DO NOT COLLECT POSTGRES SSP DB IN VIOS 3.1.4.31 /4.1.0.X

IJ51178

IO fails before recovery_wait time with cablepul

IJ51179

ioslevel change for 72Z to 3.1.4.41 and for 73D to 4.1.0.21

IJ51215

crashed in ct_hook1