VIOS 3.1.4.31 Release Notes

Package Information

PACKAGE: Update Release 3.1.4.31
IOSLEVEL: 3.1.4.31

VIOS level is

The AIX level of the NIM Master level must be equal to or higher than

Update Release 3.1.4.31

AIX 7200-05-07

General package notes

Be sure to heed all minimum space requirements before installing.

Review the list of fixes included in Update Release 3.1.4.31

To take full advantage of all the functions available in the VIOS, it may be necessary to be at the latest system firmware level. If a system firmware update is necessary, it is recommended that the firmware be updated before you update the VIOS to Update Release 3.1.4.31.

Microcode or system firmware downloads for Power Systems

If the VIOS being updated has filesets installed from the VIOS Expansion Pack, be sure to update those filesets with the latest VIOS Expansion Pack if updates are available.

Update Release 3.1.4.31 updates your VIOS partition to ioslevel 3.1.4.31. To determine if Update Release 3.1.4.31 is already installed, run the following command from the VIOS command line.

$ ioslevel

If Update Release 3.1.4.31 is installed, the command output is 3.1.4.31.

Note: The VIOS installation DVDs and the level of VIOS preinstalled on new systems might not contain the latest fixes available. It’s highly recommended that customers that get the physical GA level (i.e., 3.1.4.30) to update to the electronic GA levels (i.e., 3.1.4.31) as soon as possible. Missing fixes might be critical to the proper operation of your system. Update these systems to a current service pack level from Fix Central.

For Customers using NVMe Over Fabric (SAN) as their Boot Disk

 

Booting from NVMeoF disk may fail if certain fabric errors are returned, hence a boot disk set up with multiple paths is recommended.  In case there is a failure to boot, the boot process may continue if you exit from the SMS menu. Another potential workaround is to discover boot LUNs from the SMS menu and then retry boot.

 

For Customers Using Third Party Java-based Software 

This only applies to customers who both use third party Java based software and have run updateios -remove_outdated_filesets to remove Java 7 from their system.

To prevent errant behavior when editing customer’s /etc/environment file, updateios does not make changes to that file when run. If a customer is using software that depends on using Java and having the path to it in your PATH environment variable, the following edit should be made to allow programs that use the PATH environment variable to locate Java 8.

In the /etc/environment file, customers should see:

 

PATH=[various directories]:/usr/java7_64/jre/bin:/usr/java7_64/bin

 

To address a potential issue with Java-dependent third party software, this should be converted to:

PATH=[various directories]:/usr/java8_64/jre/bin:/usr/java8_64/bin

ITM Agents Software
  ITM (IBM Tivoli Monitoring) filesets continue to be pre-installed as part of VIOS 3.x.  The agents can be updated using one of the methods below:

·        To update the agent and shared components (e.g. JRE, GSKt) to the latest levels, download the latest image included in the IBM Tivoli Monitoring System P Agents 6.22 Fix Pack 4 bundle .  Here is a link to the readme file containing information about how to obtain the image and instructions for installing.  

·        To update just the agent shared components (e.g JRE, GSKit), the latest ITM service pack can be installed.

 

 

LDAP fileset updates

 

For VIOS partitions originally installed at 3.1.4.30 or later, errors updating the idsldap 6.4 filesets can be safely ignored as version 10.0 of the idsldap filesets are already present on the system.

 

Please ignore below errors:

 

installp:  APPLYING software for:

        idsldap.license64.rte 6.4.0.25

Error: IBM Security Directory Server License not detected. Install cannot continue.

instal:  Failed while executing the idsldap.license64.rte.pre_i script.

 

 

0503-464 installp:  The installation has FAILED for the "usr" part

        of the following filesets:

        idsldap.license64.rte 6.4.0.25

 

installp:  Cleaning up software for:

        idsldap.license64.rte 6.4.0.25

 

 

Please ignore below entries in “Installation Summary” :

 

idsldap.license64.rte       6.4.0.25        USR         APPLY       FAILED

idsldap.license64.rte       6.4.0.25        USR         CLEANUP     SUCCESS

idsldap.cltbase64.rte       6.4.0.25        USR         APPLY       CANCELED

idsldap.cltbase64.adt       6.4.0.25        USR         APPLY       CANCELED

idsldap.clt64bit64.rte      6.4.0.25        USR         APPLY       CANCELED

idsldap.clt32bit64.rte      6.4.0.25        USR         APPLY       CANCELED

 

 

Note

 

·        If the Virtual I/O servers are installed on POWER10 systems and configured with “32Gb PCIe4 2-Port FC Adapter, Feature Code(s) EN1J and EN1K”, then the requirement is to update the adapter microcode level to 7710812214105106.070115 before updating the Virtual I/O server to 3.1.4.31 level.

 

Please refer to the release notes at this link

 

3.1.4.31 New Features

VIOS 3.1.4.31 adds the following new features:

 

VIOS Shared Storage Pool Logging Enhancements

The two major enhancements for VIOS Shared Storage Pool in this release are as follows:

·       The creation of dbn.log file within a Shared Storage Pool (SSP).
This file tracks all elections and relinquishes of the Database Node (DBN) role and debugs DBN-related problems easily.

·       The compression and storage of vio_daemon logs.
The number of logs that can be retained is increased by 15 times with no impact to storage capacity. This is done by compressing old VIOS logs and by tagging them with appropriate date and time information. This reduces the risk of logs that might contain critical information from being overwritten by newer logs.


N_Port ID Virtualization (NPIV) Enhancements: NVMeoF Protocol Support

The NPIV is a standardized method for virtualizing a physical Fibre Channel (FC) port. An NPIV-capable FC host bus adapter (HBA) can have multiple N_Ports, each with a unique identity. The NPIV, coupled with the adapter-sharing capabilities of the Virtual I/O Server (VIOS), allows a physical Fibre Channel HBA to be shared across multiple guest operating systems. The PowerVM implementation of NPIV enables POWER® logical partitions (LPARs) to have virtual fibre channel host bus adapters, each with a dedicated
worldwide port name. Each virtual Fibre Channel HBA has a unique storage area network (SAN) identity similar to that of a dedicated physical HBA.

The Non-Volatile Memory Express over Fabrics (NVMeoF) protocol in the NPIV stack is supported in Virtual I/O Server Version 3.1.4.0. A single virtual adapter provides access to both Small Computer Systems Interface (SCSI) and NVMeoF protocols if the physical adapter can support them. The application, which is running on the client partition and capable of handling the NPIV-NVMeoF protocol, can send I/Os in parallel to SCSI and NVMeoF disks that are coming from a single virtual adapter. The hardware and software requirements for NVMeoF protocol enablement in the NPIV stack are as follows:

·       VIOS Version 3.1.4.0, or later

·       NPIV-NVMeoF capable client (currently AIX® Version 7.3 Technology Level 01, or later)

·       POWER 10 system with firmware version FW 1030, or later

·       32 or 64 GB FC adapters with physical NVMeoF support


VIOS Operating System Monitoring Enhancement

 

This release adds support for monitoring the VIOS operating system state by the POWER Hypervisor. If the VIOS partition is not responsive (due to certain conditions), then the hypervisor restarts the VIOS partition while it takes the system dump for debugging purpose. This helps to recover the VIOS partition from errors, for example, if the CPU is hijacked by the highest-level interrupt, the system progress is stopped. The ioscli viososmon command is added to understand the hang detection interval and the action when the hang is detected. This support requires POWER firmware version FW 1030, or later and VIOS Version 3.1.4.0, or later.

 

Support for NFSv4 Mounts on VIOS

 

The ioscli mount command which previously, by default, only supported the NFSv3 mount of the AIX is updated to support NFSv4 mounting. The changes allow VIOS to be able to invoke commands for the following actions:

·       Setting Network File System (NFS) domain using chnfsdom from command line interface (CLI)

The setting of the NFS domain is accomplished by adding a Role-based access control (RBAC) support for the
chnfsdom command.

·       Invoking the NFSv4 mounting

The ioscli mount command is updated to support invoking the NFSv4 mounting. The current ioscli mount command defaults to NFSv3. You can invoke the “o vers=4” option with the new “-nfsvers <version> <Node: > <Directory> < Directory>” option that is added to the ioscli mount command. The values that are supported for the version are 3 and 4.


Note
: The ioscli mount command supports NFS versions that are supported by the AIX mount command.

·       Starting the nfsrgyd daemon

For version 4, if the mount is successful, a check is done to see if the nfsrgyd daemon is already started. And if it has not yet started, the nfsrgyd daemon is started.

Hardware Requirements

VIOS 3.1.4.31 can run on any of the following Power Systems:

 

POWER 8 or later.

Known Capabilities and Limitations

The following requirements and limitations apply to Shared Storage Pool (SSP) features and any associated virtual storage enhancements.

Requirements for Shared Storage Pool

 

Limitations for Shared Storage Pool

Software Installation

SSP Configuration

Feature

Min

Max

Number of VIOS Nodes in Cluster

1

16*

Number of Physical Disks in Pool

1

1024

Number of Virtual Disks (LUs) Mappings in Pool

1

8192

Number of Client LPARs per VIOS node

1

250*

Capacity of Physical Disks in Pool

10GB

16TB

Storage Capacity of Storage Pool

10GB

512TB

Capacity of a Virtual Disk (LU) in Pool

1GB

4TB

Number of Repository Disks

1

1

Capacity of Repository Disk

512MB

1016GB

Number of Client LPARs per Cluster

1

2000

 

*Support for additional VIOS Nodes and LPAR Mappings:

Prerequisites for expanded support:

Here are the new maximum values for each of these configuration options, if the associated hardware specification has been met:

Feature

Default Max

High Spec Max

Number of VIOS Nodes in Cluster

16

24

Number of Client LPARs per VIOS node

250

400

 

Other notes:


Network Configuration


Storage Configuration


Shared Storage Pool capabilities and limitations

Installation Information

Pre-installation Information and Instructions

Please ensure that your rootvg contains at least 30 GB and that there is at least 4GB free space before you attempt to update to Update Release 3.1.4.31. Run the lsvg rootvg command, and then ensure there is enough free space.

Example: 

$ lsvg rootvg 
 
 
 
VOLUME GROUP:       
rootvg                   
VG IDENTIFIER:  
00f6004600004c000000014306a3db3d
VG STATE:
active     
PP SIZE:
64 megabyte(s)
VG PERMISSION:            
read/write               
TOTAL PPs:
511 (32704 megabytes)
MAX LVs:                   
256                      
FREE PPs:
64 (4096 megabytes)
LVs:                       
14                       
USED PPs:
447 (28608 megabytes)
OPEN LVs:                    
12 
QUORUM:
2 (Enabled)
TOTAL PVs:                                  
1
VG DESCRIPTORS:
2
STALE PVs:                                  
0
STALE PPs: 
0
ACTIVE PVs:                                         
1
AUTO ON:
yes
MAX PPs per VG:     
32512                                     
 
 
MAX PPs per PV:     
1016 
MAX PVs:
32
LTG size (Dynamic):                
256 kilobyte(s)
AUTO SYNC:
no
HOT SPARE:                
no                       
BB POLICY:
relocatable
PV RESTRICTION:     
none                     
INFINITE RETRY:
no
 
 

VIOS upgrades with SDDPCM

 

A single, merged lpp_source is not supported for VIOS that uses SDDPCM. However, if you use SDDPCM, you can still enable a single boot update by using the alternate method described at the following location:

 

 

Updating from VIOS version 3.1.0.00

 

VIOS Update Release 3.1.4.31 may be applied directly to any VIOS at level 3.1.0.00.

 

Upgrading from VIOS version 2.2.4 and above

 

The VIOS must first be upgraded to 3.1.0.00 before the 3.1.4.31 update can be applied.  To learn more about how to do that, please read the information provided here.

 

Before installing the VIOS Update Release 3.1.4.31

 

Warning: The update may fail if there is a loaded media repository.

 

Instructions: Checking for a loaded media repository

 

To check for a loaded media repository, and then unload it, follow these steps.

 

1.     To check for loaded images, run the following command:

$ lsvopt 
The Media column lists any loaded media.

 

2.     To unload media images, run the following commands on all Virtual Target Devices that have loaded images.

$ unloadopt -vtd <file-backed_virtual_optical_device >

 

3.     To verify that all media are unloaded, run the following command again.

$ lsvopt 
The command output should show No Media for all VTDs.



Instructions: Migrate Shared Storage Pool Configuration

 

The Virtual I/O Server (VIOS) Version 2.2.2.1 or later, supports rolling updates for SSP clusters. The VIOS can be updated to Update Release 3.1.4.31 using rolling updates.

Non-disruptive rolling updated to VIOS 3.1 requires all SSP nodes to be at VIOS 2.2.6.31 or later. See detailed instructions in the VIOS 3.1 documentation

 

The rolling updates enhancement allows the user to apply Update Release 3.1.4.31 to the VIOS logical partitions in the cluster individually without causing an outage in the entire cluster. The updated VIOS logical partitions cannot use the new SSP capabilities until all VIOS logical partitions in the cluster are updated.

 

To upgrade the VIOS logical partitions to use the new SSP capabilities, ensure that the following conditions are met:

 

·        All VIOS logical partitions must have VIOS Update Release version 2.2.6.31 or later installed.

·        All VIOS logical partitions must be running. If any VIOS logical partition in the cluster is not running, the cluster cannot be upgraded to use the new SSP capabilities.

Instructions: Verify the cluster is running at the same level as your node.

 

1.     Run the following command:
$ cluster -status -verbose

2.     Check the Node Upgrade Status field, and you should see one of the following terms:


UP_LEVEL: This means that the software level of the logical partition is higher than the software level the cluster is running at.

ON_LEVEL: This means the software level of the logical partition and the cluster are the same.

 

Installing the Update Release

 

There is now a method to verify the VIOS update files before installation. This process requires access to openssl by the 'padmin' User, which can be accomplished by creating a link.

 

Instructions: Verifying VIOS update files.

To verify the VIOS update files, follow these steps:

1.     $ oem_setup_env

2.     Create a link to openssl 
# 
ln -s /usr/bin/openssl /usr/ios/utils/openssl 

3.     Verify the link to openssl was created 
# 
ls -alL /usr/bin/openssl /usr/ios/utils/openssl 

4.     Verify that both files display similar owner and size 

5.     # exit

 

Use one of the following methods to install the latest VIOS Service Release. As with all maintenance, you should create a VIOS backup before making changes.

 

If you are running a Shared Storage Pool configuration, you must follow the steps in Migrate Shared Storage Pool Configuration.

 

Note: While running 'updateios' in the following steps, you may see accessauth messages, but these messages can safely be ignored.

 

Version Specific Warning: Version 2.2.2.1, 2.2.2.2, 2.2.2.3, or 2.2.3.1

You must run updateios command twice to get bos.alt_disk_install.boot_images fileset update problem fixed.

 

Run the following command after the step of "$ updateios –accept –install –dev <directory_name >" completes.

$ updateios –accept –dev <directory_name >

 

Depending on the VIOS level, one or more of the LPPs below may be reported as "Missing Requisites", and they may be ignored.

MISSING REQUISITES: 

     X11.loc.fr_FR.base.lib 4.3.0.0        # Base Level Fileset
     bos.INed 6.1.6.0                      # Base Level Fileset
     bos.loc.pc.Ja_JP 6.1.0.0              # Base Level Fileset
     bos.loc.utf.EN_US 6.1.0.0             # Base Level Fileset
     bos.mls.rte 6.1.x.x                   # Base Level Fileset

 

Warning:  If VIOS rules have been deployed.


During update, there have been occasional issues with VIOS Rules files getting overwritten and/or system settings getting reset to their default values.

 

To ensure that this doesn’t affect you, we recommend making a backup of the current rules file.  This file is located here:

/home/padmin/rules/vios_current_rules.xml


First, to capture your current system settings, run this command:

$
rules -o capture

 

Then, either copy the file to a backup location, or save off a list of your current rules:

 

$ rules -o list > rules_list.txt

 

After this is complete, proceed to update as normal.  When your update is complete, check your current rules and ensure that they still match what is desired.  If not, either overwrite the original rules file with your backup, or proceed to use the ‘rules -o modify’ and/or ‘rules -o add’ commands to change the rules to match what is in your backup file.

 

Finally, if you’ve failed to back up your rules, and are not sure what the rules should be, you can deploy the recommended VIOS rules by using the following command:

$ rules -o deploy -d

 

Then, if you wish to copy these new VIOS recommended rules to your current rules file, just run:

 

$ rules -o capture

 

Note: This will overwrite any customized rules in the current rules file.

 

Applying Updates

 

Warning:

If the target node to be updated is part of a redundant VIOS pair, the VIOS partner node must be fully operational before beginning to update the target node.

 

Note:

For VIOS nodes that are part of an SSP cluster, the partner node must be shown in 'cluster -status ' output as having a cluster status of OK and a pool status of OK. If the target node is updated before its VIOS partner is fully operational, client LPARs may crash.

 

 

Instructions: Applying updates to a VIOS.

 

  1. Log in to the VIOS as the user padmin.
  2. If you use one or more File Backed Optical Media Repositories, you need to unload media images before you apply the Update Release. See details here.
  3. If you use Shared Storage Pools, then Shared Storage Pool Services must be stopped.

    $
     clstartstop -stop -n <cluster_name > -m <hostname >

  4. To apply updates from a directory on your local hard disk, follow the steps:
    1. Create a directory on the Virtual I/O Server.
      $
       mkdir <directory_name >

2.     Using ftp, transfer the update file(s) to the directory you created.

To apply updates from a remotely mounted file system, and the remote file system is to be mounted read-only, follow the steps:

      1. Mount the remote directory onto the Virtual I/O Server:
        $
         mount remote_machine_name:directory /mnt

The update release can be burned onto a CD by using the ISO image file(s). To apply updates from the CD/DVD drive, follow the steps:

      1. Place the CD-ROM into the drive assigned to VIOS.

  1. Commit previous updates by running the updateios command:
    $
     updateios -commit

  2. Verify the updates files that were copied. This step can only be performed if the link to openssl was created.
    $ 
    cp <directory_path >/ck_sum.bff /home/padmin 
    $ 
    chmod 755 </home/padmin>/ck_sum.bff 
    $ 
    ck_sum.bff <directory_path > 
    If there are missing updates or incomplete downloads, an error message is displayed.

    To see how to create a link to openssl, click
    here.

  3. Apply the update by running the updateios command
    $
     updateios -accept -install -dev <directory_name >

  4. To load all changes, reboot the VIOS as user padmin .

$ shutdown -restart

 

Note: If shutdown –restart command failed, run swrole –PAdmin for padmin to set authorization and establish access to the shutdown command properly.

  1. If cluster services were stopped in step 3, restart cluster services.

$ clstartstop -start -n <cluster_name > -m <hostname >

  1. Verify that the update was successful by checking the results of the updateios command and by running the ioslevel command, which should indicate that the ioslevel is now 3.1.4.31.

$ ioslevel

Post-installation Information and Instructions

Instructions: Checking for an incomplete installation caused by a loaded media repository.

 

After installing an Update Release, you can use this method to determine if you have encountered the problem of a loaded media library.

Check the Media Repository by running this command: 
$ 
lsrep

If the command reports: "Unable to retrieve repository data due to incomplete repository structure," then you have likely encountered this problem during the installation. The media images have not been lost and are still present in the file system of the virtual media library.

 

Running the lsvopt command should show the media images.

 

Instructions: Recovering from an incomplete installation caused by a loaded media repository.

 

To recover from this type of installation failure, unload any media repository images, and then reinstall the ios.cli.rte package. Follow these steps:

1.     Unload any media images

$ unloadopt -vtd <file-backed_virtual_optical_device>

2.     Reinstall the ios.cli.rte fileset by running the following commands.

To escape the restricted shell: 
$ 
oem_setup_env 
To install the failed fileset: 
# 
installp –Or –agX ios.cli.rte –d <device/directory > 
 To return to the restricted shell: 
# 
exit

3.     Restart the VIOS.

$ shutdown –restart

4.     Verify that the Media Repository is operational by running this command:

$ lsrep

Fixes included in this release

The list of fixes in 3.1.4.31

 

APAR

Description

IJ41832

Install images for bos.loc.utf.JA_JP

IJ42481

SECLDAPCLNTD DOES NOT RECOGNIZE OPENLDAP PASSWORD POLICY

IJ42703

LDAP NESTED GROUP DELAYS DUE TO NO CACHING

IJ43419

PROCFILES FAILS TO PRINT ALL FILENAMES OF DB2SYSC PROCESS

IJ43890

DBN ELECTION MAY TAKE LONG TIME CAUSING VMRM FAILOVER DELAY

IJ44109

LNC2ENTDD NEEDS LSO SECURITY CHECK IN VNIC PATH

IJ44502

LSGROUP WON'T WORK WITH SPACE IN GROUP NAME

IJ44503

LSUSER MAY NOT DISPLAY ALL OF AN LDAP USER'S GROUPS

IJ44714

AIXPERT -U DOES NOT RESTORE DEFAULT USER SETTINGS

IJ45056

POTENTIAL SECURITY ISSUE

IJ45256

SNAP -A (WITHOUT N) GIVE ERRORS ON CHECKING SPACE WITH NIM

IJ45529

VIOS CRASH DURING VFCHOST ADAPTER CONFIGURATION

IJ45657

CHVG USAGE ERROR WHEN CALLED FROM ALT_ROOTVG_OP -W

IJ45823

vlandd: add tracing to provide better troubleshooting

IJ45879

VIRTUAL TAPE DEVICE OPERATIONS MAY FAIL IN AIX 7.2 TL5

IJ45885

THE ISSUE FROM APAR IJ41424 REOCCURS IN AIX 7200-05-05-2246

IJ46163

P10FIELD_HMC UI ADD VFC ADAPTERS "FAILED" WITH HSCLA9D7 HSCLA27

IJ46352

VIOS CONFIGURED WITH MANY ROCE ADAPTERS CAN EXHAUST PINNEDMEMORY

IJ46384

OFED DRIVERS MEMORY LEAK WHEN ROCE ADAPTERS CONFIGURED WITH RDMA

IJ46490

IANA Olson timezone Rules file updates for 2023c version.

IJ46541

potential undetected data loss after running chvg -ky or chvg -g

IJ46596

IMPROPER ASSIGNEMNT FIX IN AIXDISKPCMKE.C

IJ46694

LDAP user logins stop working

IJ46710

Set ANA Delay as per ANATT

IJ46755

NO LVM STATS RETURNED FOR SOME ACTIVE VGS DUE TO INACTIVE VGS

IJ46798

.VI_HISTORY FILE IS NOT CREATING AUTOMATICALLY

IJ46854

IO path timeout and IO failures VFC multi-queue on AIX

IJ46855

vfc adapter reset after migration upon ACA condition from

IJ46866

IN PS OUTPUT COMMANDS ARGUMENTS MISSING IF ONE ARGUMENT IS NULL

IJ46867

ZAMBIE PROCESS IS LEFT BEHIND WHEN BOOT IS DONE.

IJ46870

SNAP OR SNAP SVCOLLECT FAILED TO COLLECT CMDB WHEN RUN IN PADM

IJ46871

INCORRECT STATE SET FOR NETWORK INTERFACE WITH CONFIGURED ALIAS

IJ46874

ICONV UCCINIT CORE DUMPS IF UCS TABLE PERMISSIONS ARE RESTRICT

IJ46875

ALT_DISK_COPY -T -G FAIL IN JFS2J2 BOOTABLE DISK CHECK

IJ46876

LPPCHK -C SHOWS DIRECTORIES NOT FOUND FOR IOS.DATABASE.RTE

IJ46879

IPREPORT FORMATTING TCPDUMP TIMESTAMPS INCORRECTLY

IJ46880

Alternate Master sync using "smit nim_altmstr" fast path fails

IJ46881

In-Core Crypto enablement fails on P9_base mode

IJ46883

suma task defaults help for FilterML attribute mislead

IJ46885

UDAPL communication does not work if used as loopback

IJ46886

NIMSH service in NIM client stops while Alt_mstr sync

IJ46889

Esc chars in cmdnim.msg error msgs not reflectd in console

IJ46890

A POTENTIAL SECURITY ISSUE EXISTS

IJ46891

getwc illegal wide character

IJ46892

MULTIPLE LEAKS IN TRUSTCHK -N TREE

IJ46893

Shutdown hangs when console redirected to a file

IJ46895

Test fails in tetoldif with Failed on LDAP (TSD)

IJ46896

SED-enabled adapter going "Defined" state after hotplug

IJ46897

Incorrect message with SMIT panel to attach the Namespace

IJ46898

cfgmgr is in hung state in NPIV client lpar

IJ46899

port speed is 0 for Nool VFC port

IJ46900

8680ff1514100000 driver ignoring module 7 burn return code.

IJ46901

dlsym failed with EINVAL during VMRM operation

IJ46902

viosbr restore may fail due to xml "id" attr

IJ46939

SPOT creation should comeout gracefully if nim server at lower

IJ46940

NIM command is unable to print NIM Master's certificate

IJ46941

MaxFSSize field doesn't work as per SUMA documentation

IJ46942

cloud_setup hangs as ftp blocks for ftp.software.ibm.com

IJ46945

NIM Master doesn't give errors on certificate expiration

IJ46946

Alt Mstr gives unsecure conn

IJ46947

nim_master_setup command help is incomplete

IJ46949

System crashes in mstor_restart_handler with USB devices

IJ46950

Disk error when using single_path reserves

IJ47025

Validation failure during migration may be seen

IJ47026

C_CH_NFSEXP OVERFLOW WITH LARGE MKSYSB FILE

IJ47062

TAIL -NXX MAY DISPLAY MORE LINES

IJ47077

SAVEBASE MAY FAIL WITH 4K BLOCK SIZE DISK

IJ47089

Compiler issue with main source file name

IJ47090

VFC Client may fail to configure disks

IJ47110

LPM Failed with LU validation syscall error

IJ47149

VIOS CRASHES IN NPIV_STOP_PROC_HANDLER DURING LUN VALIDATION

IJ47158

VIOS LOGS CONTINUOUS SC_DISK_ERR10 FOR PPRC SECONDARY DISK

IJ47199

Customer facing problem with 'lspv -P' not showing all disks

IJ47209

BDIFF MUST RETURN NON-ZERO IF FILES ARE DIFFERENT

IJ47210

Probable system crash during FC driver configuration

IJ47238

VIOS crashes while LPM validation for FCNVMe disks

IJ47318

CHANGING LANG in bsh jobs causes termination in SIGSEGV.

IJ47322

Improve binder Error Message When It Cannot Load libLTO.so

IJ47341

WHEN VIOS GOES DOWN, VSCSI DISK I/O MIGHT HANG

IJ47355

IPSEC tunnel PSK AIX <> ZOS fails to rekey for DH 19

IJ47401

LPM failed for lpar name more than 32 bytes long

IJ47450

getconfattr returns wrong errno

IJ47455

After LPM npiv client is not accessible

IJ47459

Provide 64-bit assembler as non-default assembler

IJ47527

netstat -P is not displaying proper error message

IJ47534

LPAR got hung while running IO tests with Livedump

IJ47535

IPv6 IPs are not pinging from other network

IJ47573

Migration of multiple lpars fail if low level startinitr fails

IJ47574

LPAR crashed at .backt+000000 while creating threads post LPM

IJ47597

A potential security issue exists

IJ47598

HOSTSALLOWEDLOGIN OR HOSTSDENIEDLOGIN LIST MIGHT FAIL

IJ47637

Update get_fw_version routine

IJ47640

LPAR CRASH DURING INTENSE WORKLOAD AT LVM LAYER

IJ47688

echo command failure

IJ47690

lldpd daemon is crashing on adding a EtherChannel

IJ47718

A possibility of memory leak case in viod_daemon.

IJ47719

DLPAR with Moso results in Core Dump

IJ47720

ADD /ETC/MAIL/SUBMIT.CF TO 'SNAP -T' DATACOLLECTION

IJ47722

HMC mgmt obj passwd_file not replicated in Alt_mstr

IJ47723

bootimage space issue during migration

IJ47743

NIM SPOT CREATION AND CHECK REPORT NFS_CNTL FAILED

IJ47761

Incorrect handling of FC asynchronous Extended Link Services commands

IJ47795

Got postgress@raise in VIOS

IJ47796

VIOS crashes with stack @npiv_enqueue+000010

IJ47797

AIX lpar can hang or crash on FC_NVM command in LPM validation.

IJ47798

'#define malloc vec_malloc' causes error/warning with ibm-clang

IJ47810

KSH BUILTIN 'PWD' AND 'CD ..' ARE LEAKING MEMORY

IJ47811

LPAR crashed with stack vfc_cancel_pending_admin_cmds

IJ47814

Migration validation failure after FC NVM command timeout

IJ47815

VIOS system dump with stack npiv_cmdq_logout_action

IJ47817

nim_update_all cmd gives success exit code for failure

IJ47830

Errors Observed during cache.mgt fileset installation.

IJ47832

EID being logged in errpt during the adapter firmware upgrade

IJ47833

In Etherchannel-teaming mode possible to add same adapter name

IJ47839

LDATA_DESTROY CALLED AFTER FAILED LDATA_CREATE CAUSES AN ASSERT

IJ47868

APPLYING BOS.RTE.SERV_AID UPDATE MAY LOOP INFINATELY

IJ47887

SEA creation fails when ipv6 offload is not supported

IJ47888

IO Erros seen after IO response drop and with Host crash

IJ47900

SAVEVG FAILS TO BACKUP SOME ATTRIBUTES OF CONCURRENT-CAPABLE VGS

IJ47901

aso dumps core during mpss optimization

IJ47905

unamex should  be declared in sys/utsname.h

IJ47919

ALT_DISK_INSTALL CLEANS ALTINST_ROOTVG IF SETUP_WORKDIR FAILS

IJ47924

lsmap not listing the client id

IJ47944

RMDEV -L FCSX ON VFC ADAPTER HUNG

IJ47947

Adapter went into defined state while config

IJ47949

NFS CAN ABEND WITH TRUSTED BINARY/SCRIPT ON AN NFS FS

IJ47971

Memory leak or system crash when using cached routes

IJ48036

SSL not enabled for NIM Primary, Alternate and NIM client

IJ48038

nim -o showres with fileset attribute throws error on lpp

IJ48039

Incomplete error msg on LU cmd if NIM client is not conf

IJ48040

nim master and client conn ok,nim cmds are failing

IJ48044

alt_rootvg_op -X is removing vg, which is nt copy of rootvg

IJ48050

Configured 1500 mtu is reset to 9000 if use_jumbo_frames=set

IJ48051

System crash while stop virtual initiator (SCIOLSTOPINITR)

IJ48239

Console getting spanned while updating mcr.rte fileset

IJ48245

READVGDA PREFERRED READ VALUE FOR SVG W/ MIRROR POOLS INCORRECT

IJ48250

Update Diagnostics VRMF for Fall 2023

IJ48252

A potential security issue exists

IJ48270

Avoid starting ksys_hsmon in non VMRM HA environment.

IJ48306

vmstat output fi/fo seems incorrect when system is in a paging

IJ48348

bosboot command fails with not enough space error

IJ48354

Observing SCSI path recovery failed on cable pull tests

IJ48355

create_ova created image will not import into PowerVC

IJ48471

tail(1) misidentifies directories as files

IJ48473

dd doesn't write status to error stream when SIGINT

IJ48474

cksum issue with multiple argument when env XPG_SUS_ENV is set

IJ48475

tail -c fails with zero exit status

IJ48476

A potential security issue exists

IJ48478

CHNFSMNT CAN INCORRECTLY MODIFY OPTIONS IN /ETC/FILESYSTEM

IJ48479

cdpd does not add multicast address during port add operation

IJ48481

A potential security issue exists

IJ48482

A potential security issue exists

IJ48483

Increase max ldata pool limit in pfcurh

IJ48488

VIOS crashed with stack ___memmove64 -> npiv_passthru_

IJ48549

VIOS CAN CRASH DURING ASYNC EVENT ON UNMAPPED VFCHOST

IJ48604

Extra break statement in the middleware find_devices code path

IJ48606

lpar crashed @tcp_trace+00009C

IJ48663

A potential security issue exists

IJ48671

A potential security issue exists

IJ48686

echo writes new line dropping code 72Z and 73B

IJ48765

DISK OPERATION ERROR: PATH HAS FAILED