About cookies on this site Our websites require some cookies to function properly (required). In addition, other cookies may be used with your consent to analyze site usage, improve the user experience and for advertising. For more information, please review your options. By visiting our website, you agree to our processing of information as described in IBM’sprivacy statement. To provide a smooth navigation, your cookie preferences will be shared across the IBM web domains listed here.
Product Documentation
Abstract
System service parts for IBM BladeCenter E (Type 8677, 1881)
Content
Move the pointer over the part for a description. Click the part to locate the part number.
Note: If your specific model is not listed, please use the Quick path feature on the right-nav, and refer to the product description. Look for the "Based on" model.
Notes:
- Field replaceable units (N) should be serviced only by qualified field service technicians. Customer replaceable units (CRU) can be replaced by the customer.
Number | Description | Replacement part number | CRU |
---|---|---|---|
1 | Chassis | ||
(all models) | 25R8172 | FRU | |
2 | Filler blade | ||
(all models) | 49P2517 | CRU | |
(models 1Xx, 2Xx, 2Gx, 3Rx 3Sx 3Xx, 4Sx, 3Tx, 4Tx) | 39M3317 | CRU | |
(model 3Rx) (optional all models) | 39M3264 | CRU | |
3 | Bezel | ||
(all models except 3Rx, 3Sx, 3Tx, 3Xx, 4Sx, 4Tx) | 49P2521 | CRU | |
(models 3Rx, 3Xx) | 39M3200 | CRU | |
(models 3Sx, 3Tx, 4Sx, 4Tx) | 46C5450 | CRU | |
4 | BladeCenter system service label | ||
(all models except 3Rx, 3Sx, 3Tx, 4Sx, 4Tx, 3Xx) | 26K9419 | CRU | |
(models 3Rx, 3Xx) | 39M3313 | CRU | |
(models 3Sx, 3Tx, 4Sx, 4Tx) | 46C5451 | CRU | |
5 | USB Diskette drive | ||
(primary) (all models except 3Sx, 3Tx, 4Sx, 4Tx) | 39M0109 | CRU | |
(alternate) (all models except 3Sx, 3Tx, 4Sx, 4Tx) | 39M0109 | CRU | |
6 | Optical drive | ||
CD-RW/DVD-ROM Slim (primary) (models 3Rx, 3Xx) | 43W4581 | CRU | |
CD-RW/DVD-ROM (alternate) (models 3Rx, 3Xx) | 39M3551 | ||
CD-RW/DVD-ROM (alternate) (models 3Rx, 3Xx) | 39M3561 | ||
CD-ROM, 24X (primary) (all models except 3Xx, 3Rx, 3Sx, 3Tx, 3Xx, 4Sx, 4Tx) | 39M3505 | ||
CD-ROM, 24X(alternate) (all models except 3Xx, 3Rx, 3Sx, 3Tx, 3Xx, 4Sx, 4Tx) | 26K5423 replaces 39M3505 | ||
CD-ROM, 24X (primary) (all models except 3Xx, 3Rx, 3Sx, 3Tx, 3Xx, 4Sx, 4Tx) | 26K5423 | ||
CD-ROM, 24X (alternate) (all models except 3Xx, 3Rx, 3Sx, 3Tx, 3Xx, 4Sx, 4Tx) | 06P5263 | ||
Combo drive, 24/24/24/8X (alternate) (models 3Rx, 3Xx) | 26K5439 | ||
DVD-ROM, 8X (primary) (model 3Rx) | 39M3531 | ||
DVD-ROM, 8X (alternate) (model 3Xx) | 26K5393 | ||
UltraSlim Enhanced SATA DVD-ROM (models 3Sx, 4Sx) (optional all models) | 44W3254 | ||
UltraSlim Enhanced SATA Multi-Burner (models 3Sx, 4Sx) | 44W3256 | ||
Optical Blank filler (models 3Sx, 3Tx, 4Sx, 4Ts) (optional all models) | 49Y4868 | ||
7 | Customer interface card | ||
(all models except 3Rx, 3Sx, 3Tx, 3Xx, 4Sx, 4Tx) | 90P4703 | FRU | |
8 | Media tray | ||
(all models except 3Rx, 3Sx, 3Tx, 3Xx, 4Sx, 4Tx) | 49P2522 | FRU | |
(models 3Rx, 3Xx) | 39M3207 | FRU | |
(models 3Sx, 3Tx, 4Sx, 4Tx) | 46C5447 | FRU | |
9 | CD-ROM Interposer card | ||
(all models) | 39R8542 replaces 48P9028 | CRU |
Number | Description | Replacement part number | CRU |
---|---|---|---|
1 | Midplane card | ||
(all models except 3Rx, 3Sx, 3Tx, 3Xx, 4Sx, 4Tx) | 26K9450 replaces 59P6609 | FRU | |
models 3Sx, 3Tx, 4Sx, 4Tx) | 46M0540 | FRU | |
(models 3Rx, 3Xx) | 39R8563 | FRU | |
2 | SPC chassis | ||
(all models except 3Rx, 3Sx, 3Tx, 3Xx, 4Sx, 4Tx) | 49P2530 | FRU | |
(models 3Rx, 3Sx, 4Sx, 3Xx) | 39M3223 | FRU | |
(models 3Sx, 3Tx, 4Sx, 4Tx) | 46C5453 | FRU | |
3 | Power supply module | ||
1400 W (model 1Xx) | 73P7501 | CRU | |
1800 W (models 2Gx, 2Xx, CXx) | 74P4401 | CRU | |
2000 W (models 3Rx, 3Sx, 3Tx, 3Xx) | 39Y7360 | CRU | |
2320 W (model 4Sx, 4Tx) | 39Y7400 | CRU | |
4 | Power supply filler | ||
(models 1Xx, 2Xx) | 49P2519 | CRU | |
(models 1Xx, 22x, 3Rx, 3Xx) | 39M3262 | ||
(models 3Sx, 3Tx, 4Sx, 4Tx) | 46C5470 | ||
5 | Rear customer interface card | ||
(all models except 3Rx, 3Sx, 3Tx, 3Xx, 4Sx, 4Tx) | 59P6602 | FRU | |
(models 3Rx, 3Xx) | 26R0361 | FRU | |
6 | Management Module (MM) | ||
(all models except 3Rx, 3Sx, 3Tx, 3Xx, 4Sx, 4Tx) | 39M4945 | CRU | |
Advanced Management Module 2 (AMM) | |||
(models 3Rx, 3Sx, 3Tx, 3Xx, 4Sx, 4Tx) | 60Y0621 | CRU | |
7 | Acoustic attenuation module | ||
(optional all models) | 39M3330 | CRU | |
8 | Blower with damper | ||
(all models) | 39M3225 | CRU | |
9 | Filler module | ||
(models 1Xx, 2Gx, 2Xx) | 49P2518 | CRU | |
(models 3Rx, 3Sx, 3Tx, 3Xx, 4Sx, 4Tx) | 39M3261 | ||
10 | Ethernet switch module | ||
(models 1Xx, CXx) | 26K6482 replaces 59P6620 | CRU | |
11 | Media cable with bracket | ||
(models 3Rx, 3Xx) | 39M3222 | FRU | |
(models 3Sx, 3Tx, 4Sx, 4Tx) | 46C5452 | FRU | |
. | 1 Gigabit 4-Port Ethernet Expansion Card | ||
(optional all models) | 44W4488 | CRU | |
. | 6 Port Server Connectivity module | ||
(optional all models) | 46M6151 | CRU | |
. | 10 Gigabit Ethernet 850NM Fibre SFP Plus Transceiver | ||
(all models) | 44W4411 | CRU | |
. | Bezel | ||
(optional all models) | 43X0438 | CRU | |
. | BladeCenter system board | ||
(optional all models) | 43W4506 | CRU | |
. | Cable | ||
3 m 12X -4X IB (optional all models) | 44V5085 | CRU | |
8 m 12X -4X IB (optional all models) | 44V5086 | CRU | |
8 m OB (optional all models) | 42R6157 | CRU | |
10 m 4X IB (optional all models) | 44V5084 | CRU | |
10 m 12X IB (optional all models) | 42R6158 | CRU | |
4000 mm IBT (optional all models) | 42R6155 | CRU | |
8000 mm 4X IB (optional all models) | 44V5083 | CRU | |
Copper (optional all models) | 32R1848 | CRU | |
Diskette drive to CI card (model 1Xx) | 49P2526 | CRU | |
Diskette drive to CI card (model 3Rx, 3Xx) | 39M3220 | CRU | |
DDR IB 4x to 4x 3.0 m | 45D2238 | CRU | |
DDR IB 4x to 4x 8.0 m | 45D2239 | CRU | |
Fibre Optic adapter (optional all models) | 39Y9223 | CRU | |
Fibre Channel (model CXx) | 02R9024 | CRU | |
FO Adapter Duplex RECP (optional all models) | 41V0573 | CRU | |
InfiniBand (optional all models) | 44V5082 | CRU | |
Nortel (optional all models) | 26K6541 | CRU | |
Nortel CX4 1.5 m (optional all models) | 32R1940 | CRU | |
Nortel CX4 3 m (optional all models) | 32R1944 | CRU | |
Optical Passthru OPC (optional all models) | 39Y9174 | CRU | |
Optical Passthru OPC (optional all models) | 39Y9176 | CRU | |
SDR 11 m Octopus 12x to (3) 4x's (optional all models) | 45D2409 | CRU | |
Serial breakout (optional all models) | 74P5186 | CRU | |
. | Chassis Muffler | ||
(all models) | 02R9004 | CRU | |
. | Power cord clip | ||
(all models) | 26K6038 | CRU | |
. | Nortel Fibre Channel connector | ||
(optional all models) | 26R0808 | CRU | |
. | Damper | ||
(all models) | 42C0826 | CRU | |
(all models) | 49P2532 | CRU | |
. | Ethernet dongle cable | ||
(model CXx) | 02R9024 | CRU | |
. | Front filler | ||
(models 1Xx, 2Xx, 2Gx, 3Rx, 3Sx, 3Tx, 3Xx, 4Sx, 4Tx) | 39M3317 | CRU | |
. | Filter | ||
(optional all models) | 43X0439 | CRU | |
. | ICPM Intelligent Copper Passthru module | ||
(optional all models) | 44W4486 | CRU | |
. | Insulator kit | ||
(optional all models) | 39M6608 | CRU | |
. | I/O card | ||
(optional all models) | 32R1845 | CRU | |
. | IRCL module | ||
(all models) | 73P9044 | CRU | |
. | CRU/FRU label | ||
(all models) | 46C5472 | CRU | |
. | Line cord | ||
(optional all models) | 39M5393 | CRU | |
. | Miscellaneous Parts Kit | ||
(all models except 3Rx, 3Sx, 4Sx, 3Xx)
| 49P2523 | CRU | |
. | Miscellaneous Parts Kit | ||
(all models except 3Rx)
| 26K9699 replaces 13N2659 | CRU | |
. | Miscellaneous Parts Kit | ||
(model 3RX)
| 26K9699 | CRU | |
. | Miscellaneous Parts Kit | ||
(models 3Rx, 3Xx)
| 39M3217 | CRU | |
. | Miscellaneous Parts Kit | ||
(models 3Sx, 4Sx)
| 46C5454 | CRU | |
. | Module | ||
3+7-Port (optional all models) | 32R1820 | CRU | |
3+7-Port (optional all models) | 32R1821 | CRU | |
4 GB Fibre Channel (optional all models) | 32R1836 | CRU | |
4 GB QLogic (optional all models) | 26R0888 | CRU | |
CPM (optional all models) | 46C7101 | CRU | |
CPM (optional all models) | 39Y9169 | CRU | |
Fibre Channel (model CXx) (optional all models) | 59P6621 | FRU | |
Optical (optional all models) | 02R9082 | CRU | |
Serial port (optional all models) | 71P8600 | CRU | |
. | Power cord | ||
(primary) (models 1Xx, 2Gx, 2Xx, 3Xx, 3Rx, 3Sx, 3Tx, 4Sx, 4Tx, CXx, ERx, 2Gx) | 39M5389 | CRU | |
. | PDU cord | ||
(model 1Xx) | 36L8886 | CRU | |
. | Power cable | ||
Interposer to CI card (model 1Xx) | 49P2525 | FRU | |
Interposer to CI card (models 3Rx, 3Xx) | 39M3219 | FRU | |
. | Rack Kit | ||
(model 3Rx, 3Sx, 3Tx, 4Sx, 4Tx, 3Xx)
| 39M3256 | CRU | |
. | Rails | ||
Left and right (all models except 3Rx, 3Sx, 3Tx, 31x, 4Sx, 4Tx) | 49P2610 | CRU | |
. | Signal cable | ||
Interposer to CI card (model 1Xx) | 49P2524 | CRU | |
CI card to media (model 1Xx) | 74P5227 | FRU | |
CI card to media (models 3Rx, 3Xx) | 39M3221 | FRU | |
CI card interposer to chassis (model 3Rx, 3Xx) | 39M3218 | FRU | |
. | Switch | ||
10-Port 4 GB McDATA (optional all models) | 32R1911 | CRU | |
10-Port QLogic (optional all models) | 32R1910 | CRU | |
BladeCenter SAS module (optional all models) | 39Y9193 | CRU | |
Brocade (optional all models) | 90P0164 | CRU | |
Cisco Ethernet (optional all models) | 13N2285 | CRU | |
Cisco Ethernet (optional all models) | 25R5391 | CRU | |
Cisco Fibre Channel Ethernet module assembly (optional all models) | 32R1891 | CRU | |
Cisco Copper Ethernet module (optional all models) | 32R1895 | CRU | |
Cisco 4 GB 20-Port Fiber Channel module (optional all models) | 39Y9278 | CRU | |
Cisco 4 GB 10-Port Fiber Channel module (optional all models) | 39Y9282 | CRU | |
Cisco 4 GB Shortwave SFP module (optional all models) | 41Y8602 | CRU | |
Cisco 4 GB Longwave SFP module, single (optional all models) | 41Y8603 | CRU | |
Cisco Catalyst Switch Module 3110X (MPN: 00Y3250, Old MPN: 41Y8522) | 00Y3253 | CRU | |
Cisco Catalyst Switch Module 3110G (MPN: 00Y3254, Old MPN: 41Y8523) | 00Y3257 | CRU | |
Cisco Catalyst Switch Module 3012 (MPN: 46C9272, Old MPN: 43W4395) | 46C9276 | CRU | |
Cisco Nexus 4001I Switch Module (MPN: 46C9270, Old MPN: 46M6071) | 46C9237 | CRU | |
Cisco Systems ® 4 Gigabit 10-Port Fibre Channel Switch Module (MPN: 44E5692, Old MPN: 39Y9284) | 44E5676 | CRU | |
Cisco Systems ® 4 Gigabit 20-Port Fibre Channel Switch Module (MPN: 44E5696, Old MPN: 39Y9280) | 44E5677 | CRU | |
Copper Passthru module (optional all models) | 44X1986 | CRU | |
Copper SFP 10 GB Ethernet module (optional all models) | 32R1936 | CRU | |
Ethernet module (optional all models) | 26K6482 | CRU | |
InfiniBand (optional all models) | 26K6452 | CRU | |
InfiniBand card module (optional all models) | 32R1903 | CRU | |
McDATA Fibre Channel (optional all models) | 32R1792 | CRU | |
Nortel Ethernet 6-Port Fiber (optional all models) | 32R1870 | CRU | |
Nortel Ethernet 6-Port Copper (optional all models) | 32R1869 | CRU | |
Nortel Ethernet (optional all models) | 32R1868 | CRU | |
Nortel 10 GB Uplink Ethernet (optional all models) | 32R1785 | CRU | |
Nortel ESM (optional all models) | 26K6526 | CRU | |
Nortel Fibre Channel (optional all models) | 26K6529 | CRU | |
Nortel 10 GB 850NM Fiber XFP Transceiver SR assembly (optional all models) | 32R1883 | CRU | |
Nortel 10 GB 1310 NM Fibre XFP Transceiver LR assembly (optional all models) | 32R1884 | CRU | |
Nortel 1/10 GB Uplink Ethernet module (optional all models) | 44W4407 | CRU | |
Nortel 10-Port 10 Gigabit switch module (optional all models) | 46C7194 | CRU | |
Optical Passthru module (optional all models) | 44W3323 | CRU | |
Nortel (optional all models) | 39Y9131 | CRU | |
QLogic 6-Port (optional all models) | 26K6481 | CRU | |
. | Tray | ||
Fibre Channel adapter card mount (optional all models) | 49P2514 | CRU |
Document Location
Worldwide
Applicable countries and regions
- Worldwide
[{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW20T","label":"BladeCenter E Chassis"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW20T","label":"BladeCenter E Chassis"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}}]
Was this topic helpful?
Document Information
More support for:
BladeCenter E Chassis
Document number:
799954
Modified date:
24 January 2019
UID
ibm1MIGR-46237