Troubleshooting
Problem
IBM Sterling Control Center shuts down after several hours of operation. It does this repeatedly and at more or less regular intervals.
Symptom
The engine log shows several errors like: "executeQuery - SQL Exception msg : The query has timed out".
..ultimately leading to...:
[InitCompProcCache-348-thread-1] ERROR RecoverableDAO - The query was executed 60 times for 36605 seconds. However, the engine did not succeed in performing the database operation, because of the following. Error :The query has timed out.
[InitCompProcCache-348-thread-1] ERROR RecoverableDAO - The query has timed out.
com.microsoft.sqlserver.jdbc.SQLServerException: The query has timed out.
[InitCompProcCache-348-thread-1] ERROR SQLExceptionShutdownHandler - ** SQLExceptionShutdownHandler entered with sqlex=com.microsoft.sqlserver.jdbc.SQLServerException: The query has timed out.
[InitCompProcCache-348-thread-1] ERROR SQLExceptionShutdownHandler - ** Event not updated or details on what was being done when error occurred -> The query has timed out.
[InitCompProcCache-348-thread-1] ERROR SQLExceptionShutdownHandler - The query has timed out.
com.microsoft.sqlserver.jdbc.SQLServerException: The query has timed out.
[InitCompProcCache-348-thread-1] INFO SCCEngine - com.microsoft.sqlserver.jdbc.SQLServerException: The query has timed out.
The Control Center Engine then shuts itself down because it has no reason to live without a working database connection.
Cause
The database may have become misindexed or otherwise corrupted
Environment
MS-SQL
Diagnosing The Problem
Check your Control Center engine log for signs of query timeouts leading to a shutdown
Resolving The Problem
Perform maintenance on your database to re-index your tables correctly. Consult your database vendor's documentation for details of how to do this.