Troubleshooting
Problem
The DB2 JDBC driver may hang for few minutes and then fail with SQLERRMC as "Number of HVnum is 0 or less" when using the GET DIAGNOSTICS SQL statement in an atomic context.
Cause
The reason for this error is extended indicator support which was added in DB2 V9.7 fp2. It was enabled by default in DB2 V9.7 fp2 for Java clients.
Resolving The Problem
Extended indicators can be disabled by setting the"enableExtendedIndicators" JDBC property to "no": |
[{"Product":{"code":"SSEPGG","label":"Db2 for Linux, UNIX and Windows"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Component":"--","Platform":[{"code":"PF002","label":"AIX"},{"code":"PF010","label":"HP-UX"},{"code":"PF016","label":"Linux"},{"code":"PF027","label":"Solaris"},{"code":"PF033","label":"Windows"}],"Version":"9.7;10.1","Edition":"Advanced Enterprise Server;Advanced Workgroup Server;Enterprise Server;Express;Express-C;Personal;Workgroup Server","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Was this topic helpful?