IBM Support

SLC processing is not working after upgrading to 6.1

Question & Answer


Question

After upgrading to Control Center SLC's are giving false alerts. Using a single Event Processor system.

Cause

Event Monitor logic is falling behind. Errors in Engine log.
WARN  EventMonitor - GORCR9999W:                 None: Event Monitor in catchup.  EVENT_COUNT_FOR_CATCHUP = 100  processedCount = 109  _lastEventSerialNumProcessed = 15351538

Answer

For a single EP add the engine.property BYPASS_EVENT_MONITOR_FOR_EVENTS with a value of TRUE.

[{"Product":{"code":"SS9GLA","label":"IBM Control Center"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Component":"Not Applicable","Platform":[{"code":"PF002","label":"AIX"},{"code":"PF016","label":"Linux"},{"code":"PF033","label":"Windows"}],"Version":"6.1.1;6.1.0.1;6.1","Edition":"All Editions","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]