Question & Answer
Question
After upgrading to Control Center SLC's are giving false alerts. Using a single Event Processor system.
Cause
Event Monitor logic is falling behind. Errors in Engine log.
WARN EventMonitor - GORCR9999W: None: Event Monitor in catchup. EVENT_COUNT_FOR_CATCHUP = 100 processedCount = 109 _lastEventSerialNumProcessed = 15351538
Answer
For a single EP add the engine.property BYPASS_EVENT_MONITOR_FOR_EVENTS with a value of TRUE.
[{"Product":{"code":"SS9GLA","label":"IBM Control Center"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Component":"Not Applicable","Platform":[{"code":"PF002","label":"AIX"},{"code":"PF016","label":"Linux"},{"code":"PF033","label":"Windows"}],"Version":"6.1.1;6.1.0.1;6.1","Edition":"All Editions","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Was this topic helpful?
Document Information
Modified date:
17 December 2019
UID
swg22012305