Troubleshooting
Problem
Symptom
# /opt/lenovo/toolscenter/asu/asu64 show IMM --kcs
Lenovo Advanced Settings Utility version 10.4.94M
Licensed Materials - Property of Lenovo
(C) Copyright Lenovo Corp. 2007-2017 All Rights Reserved
Connected via IPMI device driver (KCS interface)
Read of data store failed with completion code 10
Close of data store failed with completion code 10
Retry after 500ms
Read of data store failed with completion code 10
Close of data store failed with completion code 10
Retry after 500ms
Read of data store failed with completion code 10
Close of data store failed with completion code 10
Retry after 500ms
Cause
The M6 QRadar hardware appliances require a different utility to run ASU commands than what is used for the M4 and M5 hardware appliances. However, the Lenovo Advanced Settings Utility (ASU) can be used with M4 and M5 QRadar hardware appliances, Lenovo XClarity Essentials OneCLI is required for M6 QRadar hardware appliances.
Resolving The Problem
To Resolve the Problem.
Note: On QRadar 7.3.1 versions, the asu64 utility is in /opt/lenovo/toolscenter/asu
- Download the build of the ASU64 Utility .TGZ file for your appliance.
Software
BuildHardware
ApplianceOperating
SystemASU
UtilityDownload
LinkQRadar 7.3.xQRadar 7.4.xRHEL 7 ASU 10.4 Installed QRadar 7.3.xQRadar 7.4.0 GAM6 RHEL 7 OneCLI OneCLI download page QRadar 7.4.x* M6 RHEL 7 OneCLI Installed *The OneCLI utility was added in QRadar build 7.4.0 Fix Pack 1. -
From the OneCLI download page, look for the OneCLI RPM for RHEL 7.
-
Example: lnvgy_utl_lxcer_onecli01l-3.1.2_rhel_x86-64 (rpm)
-
-
Using WinSCP or another similar utility, upload the OneCLI utility to the /tmp directory on the Console.
-
Using an SSH session as root, connect to the affected appliance.
-
Use YUM to install the OneCLI utility:
yum -y install /tmp/lnvgy_utl_lxcer_onecli01l-3.1.2_rhel_x86-64.rpm
-
To test the new asu64 utility, run the command:
/opt/lenovo/lnvgy-utl-lxce-onecli/asu show IMM
Results: You now have the OneCLI utility installed.
Notes:
- OneCLI is compatible with earlier hardware versions and works with the M4 and M5 QRadar hardware appliances.
- However, the utilities use different executable files, the command structure is similar.
/opt/lenovo/toolscenter/asu/asu64 show IMM --kcs /opt/lenovo/lnvgy-utl-lxce-onecli/asu show IMM
Was this topic helpful?
Document Information
Modified date:
06 April 2023
UID