Troubleshooting
Problem
NoPermissionException: User does not have permission on weblogic.management.adminhome to perform lookup operation
Symptom
The following error may occur when starting WebLogic Application Server or running the Sterling Health Monitor:
javax.naming.NoPermissionException: User <anonymous> does not have permission on weblogic.management.adminhome to perform lookup operation
This error occurs when WebLogic Anonymous Admin Lookup is not enabled. To use Rule Execution Server with WebLogic, the option Anonymous Admin Lookup Enabled must be set to true. This flag provides the MBean API with read-only access to WebLogic Server MBeans. Registration of Full Rule Execution Server management and XU MBeans requires this access.
Error Message
2008-12-16 12:53:46,733:ERROR :Timer-7: [1229412226733] JNDI naming exception: javax.naming.NoPermissionException: User <anonymous> does not have permission on weblogic.management.adminhome to perform lookup operation. [Root exception is javax.naming.NoPermissionException: User <anonymous> does not have permission on weblogic.management.adminhome to perform lookup operation.]: YHMJMSCollectable
2008-12-16 12:53:46,733:ERRORDTL:Timer-7: [1229412226733]java.lang.IllegalArgumentException: JNDI naming exception: javax.naming.NoPermissionException: User <anonymous> does not have permission on weblogic.management.adminhome to perform lookup operation. [Root exception is javax.naming.NoPermissionException: User <anonymous> does not have permission on weblogic.management.adminhome to perform lookup operation.]
at weblogic.management.Helper.getMBeanHomeForName(Helper.java:110)
at weblogic.management.Helper.getAdminMBeanHome(Helper.java:38)
at com.yantra.ycp.hm.jms.WLSQueueBrowser.getQueueDepth(WLSQueueBrowser.java:33)
at com.yantra.ycp.hm.jms.YHMJMSCollectable.collect(YHMJMSCollectable.java:52)
at com.yantra.ycp.hm.jms.YHMSchedulableJMSMonitor.run(YHMSchedulableJMSMonitor.java:46)
at java.util.TimerThread.mainLoop(Timer.java:512)
at java.util.TimerThread.run(Timer.java:462)
: YHMJMSCollectable
Resolving The Problem
To enable Anonymous Admin Lookup Enabled parameter, follow the instructions below as described in the WebLogic documentation.
You can modify the option through the command line script:
Dweblogic.management.anonymousAdminLookupEnabled=true
Alternatively:
1. Open the WebLogic Server Administration Console.
2. In the Domain Configurations, click the name of your domain.
3. In the Settings page, click the Security tab.
4. In the Change Center, click Lock & Edit.
5. In the Security page under General, select Anonymous Admin Lookup Enabled and click Save.
6. In the Change Center, click Activate Changes.
To verify the setting of the Anonymous Admin Lookup Enabled option through the WebLogic Administration Console, see the Domain: Security: General page in the Administration Console or the attribute:
SecurityConfigurationMBean.AnonymousAdminLookupEnabled
Historical Number
NFX4568