Troubleshooting
Problem
You have instrumented CICS TS Data produced for your zAPM Connect but when you start the CICS Region following error occurs:
CSV003I REQUESTED MODULE AGMPGGA NOT FOUND
Resolving The Problem
Perform the steps below;
1 - Ensure that both SAGMMOD and SAGMODR data sets are available to the CICS Region
2 - Ensure that the CICS LIBRARY(SAGMMODR) is defined and points to the SAGMMODR data set from step 1.
2 - Ensure that the CICS LIBRARY(SAGMMODR) is defined and points to the SAGMMODR data set from step 1.
Note: The LIBRARY(SAGMMODR) library must exist. You cannot replace SAGMMODR with DFHRPL DD or STEPLIB DD statements.
Document Location
Worldwide
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJUL","label":"IBM Application Performance Management"},"Component":"","Platform":[{"code":"PF035","label":"z\/OS"}],"Version":"All Versions","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]