Question & Answer
Question
What are the supported drive types and firmware levels for IBM Storage Virtualize Family of Products.
Answer
Table below lists drive types and firmware levels for IBM Storage Virtualize Family of Products. Under some circumstances IBM Manufacturing may ship drives with more recent firmware levels than are listed on this page. These firmware levels will be fully supported so there will be no requirement to downgrade the firmware before utilising them.
The levels indicated apply to all software levels unless indicated otherwise in "Minimum Storage Virtualize Code Level" column.
The search tool can be used in conjunction with the IBM controller abbreviations to identify a product. See the abbreviations table at the bottom of this page for details. For example to find a 200GB drive for a IBM FlashSystem FS9100 enter "200GB FS9100" or to find a 400GB SSD drive for a IBM Storwize V7000 "400GB SSD V7000". Note that each search item should be separated by a space.
Description | Model Number | Minimum Supported Firmware Level | Latest Firmware Level | Recommended Software Level | Minimum Storage Virtualize Code Level | Supported Controller Enclosures | Supported Expanssion Enclosure | Comments | |
---|---|---|---|---|---|---|---|---|---|
2.5” SAS Tier 0 SSD - 200GB
|
HUSML4020ASS60
|
A302
|
J340
|
V7000, V3700, SVC | |||||
2.5” SAS Tier 0 SSD - 200GB | HUSML4020ASS60 | J3C0 | J3C0 | V5000 | Firmware version for V5000 only. | ||||
2.5” SAS Tier 0 SSD - 200GB
|
TXA2D20200GA6I
|
GB6Y
|
GB7C
|
V7000, V5000, V3700 | |||||
2.5” SAS Tier 0 SSD - 200GB
|
HUSMM8020ASS20 |
J4B5
|
J4B6
|
V7000, SVC | |||||
2.5” SAS Tier 0 SSD - 200GB
|
HUSMM1620ASS20 |
J4C7
|
J4C8
|
V7000, SVC | |||||
2.5” SAS Tier 0 SSD - 300GB
|
HK230041S |
291E
|
2936*
|
V7000 | |||||
2.5” SAS Tier 0 SSD - 300GB
|
HUSML4030ASS60
|
A302
|
J340
|
V7000 | |||||
2.5” SAS Tier 0 SSD - 300GB
|
HUSMM1630ASS20
|
J4C7
|
J4C8
|
V7000 | |||||
2.5” SAS Tier 0 SSD - 400GB
|
HUSML4040ASS60
|
A302
|
J340
|
V7000, V3700, SVC | |||||
2.5” SAS Tier 0 SSD - 400GB | HUSML4040ASS60 | J3C0 | J3C0 | V5000 | Firmware version for V5000 only. | ||||
2.5” SAS Tier 0 SSD - 400GB |
TXA2D20400GA6I
|
GB6Y
|
GB7C
|
V7000, V5000, V3700 | |||||
2.5” SAS Tier 0 SSD - 400GB |
HUSMM8040ASS20
|
J4B5
|
J4B6
|
V7000, V5000, V3700, SVC | |||||
2.5” SAS Tier 0 SSD - 400GB |
HUSMM1640ASS20
|
J4C7
|
J4C8
|
V7000, V5000, V3700 | |||||
2.5” SAS Tier 0 SSD - 400GB |
ST400FM0233
|
4C0D
|
4C1A
|
V5000 G2, V7000 G2 | V5000 G2, FS 5100, V7000 G2, FS 7200, SVC | ||||
2.5” SAS Tier 0 SSD - 400GB |
MTFDJAK400MBS
|
5C0D
|
5C1A
|
V7000, V5000, V3700, SVC | |||||
2.5" SAS SSD -400GB
|
PX04SMB040
|
540F
|
540F
|
V7000 G2 | V7000 G2, FS 7200, SVC | ||||
2.5" SAS Tier 1 SSD - 1.9TB |
XS1920SE70055 |
8385 |
8388 |
V5000 G2, FS 50X5, V7000 G2 | V5000 G2, FS 5100, V5000E, FS 5000, FS 5200, V7000 G2, FS 7200, FS 7300, SVC, FS V9000, FS 9100, FS 9200, FS 9500 | ||||
2.5" SAS Tier 1 SSD - 3.8TB |
XS3840SE70055 |
8385 | 8388 | V5000 G2, FS 50X5, V7000 G2 | V5000 G2, FS 5100, V5000E, FS 5000, FS 5200, V7000 G2, FS 7200, FS 7300, SVC, FS V9000, FS 9100, FS 9200, FS 9500 | ||||
2.5" SAS Tier 1 SSD - 7.6TB |
XS7680SE70055 |
8385 | 8388 | V5000 G2, FS 50X5, V7000 G2 | V5000 G2, FS 5100, V5000E, FS 5000, FS 5200, V7000 G2, FS 7200, FS 7300 | ||||
2.5” SAS Tier 0 SSD - 400GB
|
TXA2D20800GA6I
|
GB6Y
|
GB7C
|
V7000, V5000, V3700 | |||||
2.5” SAS Tier 0 SSD - 400GB | WUSTM3240ASS200 | J4V4 | J4V6 | V7000, V5000, V3700, SVC | |||||
2.5” SAS Tier 0 SSD - 400GB | KPM6XMUG400G | S6E6 | S6E8 | V5000 G2, V7000 G2 | V5000 G2, FS 5100, V7000 G2, FS 7200, SVC | ||||
2.5” SAS Tier 0 SSD - 400GB |
MZILT400HAHQ |
MS6C |
MS6C |
V5000 G2, V7000 G2 | V5000 G2, FS 5100, V7000 G2, FS 7200, SVC | ||||
2.5” SAS Tier 0 SSD - 400GB | XS400ME70114 | 4391 | 4391 | V5000 G2, V7000 G2 | |||||
2.5” SAS Tier 0 SSD - 800GB |
HUSMM8080ASS20
|
J4B5
|
J4B6
|
V7000, V5000, V3700, SVC | |||||
2.5” SAS Tier 0 SSD - 800GB |
HUSMM1680ASS20
|
J4C7
|
J4C8
|
V7000, V5000, V3700 | |||||
2.5” SAS Tier 0 SSD - 800GB |
ST800FM0173
|
4C0D
|
4C1A
|
V5000 G2, V7000 G2 | V5000 G2, FS 5100, V7000 G2, FS 7200, SVC | ||||
2.5” SAS Tier 0 SSD - 800GB |
MTFDJAK800MBS
|
5C0D
|
5C1A
|
V7000, V5000, V3700, SVC | |||||
2.5” SAS Tier 0 SSD - 800GB |
PX04SMB080
|
540F
|
540F
|
V7000 G2 | V7000 G2, FS 7200, SVC | ||||
2.5” SAS Tier 0 SSD - 800GB | WUSTM3280ASS200 | J4V4 | J4V6 | V7000, V5000, V3700, SVC | |||||
2.5” SAS Tier 0 SSD - 800GB | KPM6XMUG800G | S6E6 | S6E8 | V5000 G2, V7000 G2 | V5000 G2, FS 5100, V7000 G2, FS 7200, SVC | ||||
2.5” SAS Tier 0 SSD - 800GB |
MZILT800HAHQ |
MS6C |
MS6C |
V5000 G2, V50X0E, FS 50X0, FS50X5, V7000 G2 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS 5100, FS 5200, FS 5300, V7000 G2, SVC | ||||
2.5” SAS Tier 0 SSD - 800GB | XS800ME70114 | 4391 | 4391 | V5000 G2, V7000 G2 | V5000 G2, FS 5100, V7000 G2, FS 7200, SVC | ||||
2.5” SAS Tier 0 SSD - 1600GB
|
HUSMM1616ASS20
|
J4C7
|
J4C8
|
V7000, V5000, V3700, SVC | |||||
2.5” SAS Tier 0 SSD - 1600GB |
ST1600FM0003
|
4C0D
|
4C1A
|
V5000 G2 | V5000 G2, FS 5100, V7000 G2, FS 7200, SVC | ||||
2.5” SAS Tier 0 SSD - 1600GB |
MTFDJAL1T6MBS
|
5C0D
|
5C1A
|
V7000, V5000, V3700, SVC | |||||
2.5” SAS Tier 0 SSD - 1600GB |
PX04SMB160
|
540F
|
540F
|
V5000 G2, V7000 G2 | V5000 G2, FS 5100, V7000 G2, FS 7200, SVC | ||||
2.5” SAS Tier 0 SSD - 1600GB | WUSTM3216ASS200 | J4V4 | J4V6 | V7000, V5000, V3700, SVC | |||||
2.5” SAS Tier 0 SSD - 1600GB | KPM6XMUG1T60 | S6E6 | S6E8 | V5000 G2, V7000 G2 | V5000 G2, FS 5100, V7000 G2, FS 7200, SVC | ||||
2.5” SAS Tier 0 SSD - 1600GB |
MZILT1T6HALS |
MS3B | MS3E | V5000 G2, V7000 G2 | V5000 G2, FS 5100, V7000 G2, FS 7200, SVC | ||||
2.5” SAS Tier 0 SSD - 1600GB | XS1600ME70114 | 4391 | 4391 | V5000 G2 | V5000 G2, FS 5100, V7000 G2, FS 7200, SVC | ||||
2.5” SAS HDD 15K – 146GB
|
ST9146852SS
|
B62B
|
B62C
|
V7000 | |||||
IBM FlashCoreModule NVMe U.2 4.8 TB | 10140647 | 1_2_11 | 1_2_12 | 1_2_12 |
V7000 G3, FS 9100, FS 9200, V5100, FS 5100
|
NA | |||
IBM FlashCoreModule NVMe U.2 9.6 TB | 10140648 | 1_2_11 | 1_2_12 | 1_2_12 |
V7000 G3, FS 9100, FS 9200, V5100, FS 5100
|
NA | |||
IBM FlashCoreModule NVMe U.2 19.2 TB | 10140649 | 1_2_11 | 1_2_12 | 1_2_12 |
V7000 G3, FS 9100, FS 9200, V5100, FS 5100
|
NA | |||
IBM FlashCoreModule NVMe U.2 4.8/20TB | 10140653 | 2_1_2 | 2_1_12 | 2_1_12 |
V7000 G3, FS 7200, FS 9100, FS 9200, V5100, FS 5100, FS 5200
|
NA | |||
IBM FlashCoreModule NVMe U.2 9.6/20TB | 10140654 | 2_1_2 | 2_1_12 | 2_1_12 |
V7000 G3, FS 7200, FS 9100, FS 9200, V5100, FS 5100, FS 5200
|
NA | |||
IBM FlashCoreModule NVMe U.2 19.2/43.9 TB | 10140655 | 2_1_2 | 2_1_12 | 2_1_12 |
V7000 G3, FS 7200, FS 9100, FS 9200, V5100, FS 5100, FS 5200
|
NA | |||
IBM FlashCoreModule NVMe U.2 38.4/87.9 TB | 10140656 | 2_1_2 | 2_1_12 | 2_1_12 |
V7000 G3, FS 7200, FS 9100, FS 9200, V5100, FS 5100, FS 5200
|
NA | |||
IBM FlashCoreModule NVMe U.2 4.8/21.99 TB | 101406B0 | 3_0_1 | 3_1_15 | 3_1_15 | FS 5200, FS 7300 | NA | |||
IBM FlashCoreModule NVMe U.2 9.6/28.8 TB | 101406B1 | 3_0_1 | 3_1_15 | 3_1_15 | FS 9500, FS 5200, FS 7300 | NA | |||
IBM FlashCoreModule NVMe U.2 19.2/57.6 TB | 101406B2 | 3_0_1 | 3_1_15 | 3_1_15 | FS 9500, FS 5200, FS 7300 | NA | |||
IBM FlashCoreModule NVMe U.2 38.4/115.2 TB | 101406B3 | 3_0_1 | 3_1_15 | 3_1_15 | FS 9500, FS 5200, FS 7300 | NA | |||
IBM FlashCoreModule NVMe U.2 4.8/21.99 TB | 101406E2 | 4_0_4 | 4_2_7 | 4_2_7 | FS 5200, FS 7300, FS9500 | NA | |||
IBM FlashCoreModule NVMe U.2 9.6/28.8 TB | 101406E3 | 4_0_4 | 4_2_7 | 4_2_7 | FS 5200, FS 7300, FS9500 | NA | |||
IBM FlashCoreModule NVMe U.2 19.2/57.6 TB | 101406E4 | 4_0_4 | 4_2_7 | 4_2_7 | FS 5200, FS 7300, FS9500 | NA | |||
IBM FlashCoreModule NVMe U.2 38.4/115.2 TB | 101406E5 | 4_0_4 | 4_2_7 | 4_2_7 | FS 5200, FS 7300, FS9500 | NA | |||
NVME U.2
800 GB
|
1014063E | C5SC | C5SG |
FS7200, FS5100, FS5200,
V5100, FS9100, FS9200
|
|||||
NVME U.2
800 GB
|
10140685 | SN6A | SN6A |
V5100, FS 5100, FS 5200, V7000 G3, FS 7200, FS 9100, FS 9200
|
NA | ||||
NVME U.2
800 GB
|
10140689 |
C6S6 | C6S6 | V7000 G3, FS 7200, FS 9100, FS 9200, V5100, FS 5100, FS 5200 | |||||
NVME U.2
800 GB
|
101406B5 | SN93SN93 | SN95SN95 |
V5100, FS 5100, FS 5200, V7000 G3, FS 7200, FS 9100, FS 9200
|
|||||
NVME U.2
1920 GB
|
1014063F | C5SC | C5SG |
FS7200, FS5100, FS5200,
V5100, FS9100, FS9200
|
|||||
NVME U.2
1920 GB
|
1014068A | C6S6 | C6S6 |
V7000 G3, FS 7200, FS 9100, FS 9200, V5100, FS 5100, FS 5200, FS 5300, FS 7300, FS 9500
|
NA | ||||
NVME U.2
1920 GB
|
101406B6 | SN83SN83 | SN89SN89 |
V5100, FS 5100, FS 5200, FS 5300, V7000 G3, FS 7200, FS 7300, FS 9100, FS 9200, FS 9500
|
NA | ||||
NVME U.2
3840 GB
|
10140640 | C5SC | C5SG |
FS7200, FS5100, FS5200,
V5100, FS9100, FS9200
|
|||||
NVME U.2
3840 GB
|
1014068B | C6S6 | C6S6 |
V7000 G3, FS 7200, FS 9100, FS 9200, V5100, FS 5100, FS 5200, FS 5300, FS 7300, FS 9500
|
NA | ||||
NVME U.2
3840 GB
|
101406B7 | SN83SN83 | SN89SN89 |
V5100, FS 5100, FS 5200, FS 5300, V7000 G3, FS 7200, FS 7300, FS 9100, FS 9200, FS 9500
|
NA | ||||
NVME U.2
7680 GB
|
10140641 | C5SC | C5SG |
FS7200, FS5100, FS5200,
V5100, FS9100, FS9200
|
|||||
NVME U.2
7680 GB
|
1014068C | C6S6 | C6S6 |
V7000 G3, FS 7200, FS 9100, FS 9200, V5100, FS 5100, FS 5200, FS 5300, FS 7300, FS 9500
|
NA | ||||
NVME U.2
7680 GB
|
101406B8 | SN83SN83 | SN89SN89 |
V5100, FS 5100, FS 5200, FS 5300, V7000 G3, FS 7200, FS 7300, FS 9100, FS 9200, FS 9500
|
NA | ||||
NVME U.2
15360 GB
|
10140642 | C5SC | C5SG |
FS7200, FS5100, FS5200,
V5100, FS9100, FS9200
|
|||||
NVME U.2
15360 GB
|
1014068D | C6S6 | C6S6 |
FS 5200, FS 5300, FS 7300, FS 9500
|
NA | ||||
NVME U.2
15360 GB
|
101406B9 | SN83SN83 | SN89SN89 |
V5100, FS 5100, FS 5200, FS 5300, V7000 G3, FS 7200, FS 7300, FS 9100, FS 9200, FS 9500
|
NA | ||||
NVME U.2
30720 GB
|
101406BA | SN83SN83 | SN89SN89 |
FS 5200, FS 5300, FS 7300, FS 9500
|
NA | ||||
NVME U.2
1920 GB
|
1014063A | SN16 | SN1O |
V5100, FS 5100, FS 5200, FS5300, V7000 G3, FS 7200, FS 9100, FS 9200
|
NA | ||||
NVME U.2
3840 GB
|
1014063B | SN16 | SN1O |
V5100, FS 5100, FS 5200, FS5300, V7000 G3, FS 7200, FS 9100, FS 9200
|
NA | ||||
NVME U.2
7680 GB
|
1014063C | SN16 | SN1O |
V5100, FS 5100, FS 5200, FS5300, V7000 G3, FS 7200, FS 9100, FS 9200
|
NA | ||||
NVME U.2
15360 GB
|
1014063D | SN16 | SN1O |
V5100, FS 5100, FS 5200, FS5300, V7000 G3, FS 7200, FS 9100, FS 9200
|
NA | ||||
NVME (SCM)
800 GB
|
10140659 |
SN4A | SN4G |
V5100, FS 5100, FS 5200, FS 5300, V7000 G3, FS 7200, FS 9100, FS 9200
|
NA | ||||
NVME (SCM)
1600 GB |
1014065A |
SN4A | SN4G |
V5100, FS 5100, FS 5200, FS 5300, V7000 G3, FS 7200, FS 9100, FS 9200
|
NA | ||||
NVME (SCM)
1600 GB |
101406BF | C7S4C7S4 | C7S4C7S4 |
FS 7300, FS 9500
|
NA | ||||
2.5” SAS HDD 15K – 146GB |
ST9146853SS
|
B633
|
B63Q
|
V7000, V5000, V3700, V3500, | |||||
2.5” SAS HDD 15K - 146GB |
MK1401GRRB
|
SC27
|
SC2E
|
V7000, V5000, V3700, V3500 | |||||
2.5” SAS HDD 15K – 300GB
|
ST9300653SS
|
B633
|
B63Q
|
V7000, V5000, V3700, V3500 | |||||
2.5” SAS HDD 15K – 300GB |
MK3001GRRB
|
SC27
|
SC2E
|
V7000, V5000, V3700, V3500 | |||||
2.5” SAS HDD 15K – 300GB |
HUC156030CSS20
|
J2G5
|
J2GF
|
V7000, V5000, V3700, V3500 | |||||
2.5” SAS HDD 15K – 300GB |
ST300MP0005
|
B679
|
B67C
|
V7000, V5000, V3700, V3500 | |||||
2.5” SAS HDD 15K – 300GB |
ST300MP0006
|
B6A5
|
B6AB
|
V5000 G2, V7000 G2 | V5000 G2, FS 5100, V7000 G2, FS 7200, SVC | ||||
2.5” SAS HDD 15K – 600GB
|
HUC156060CSS20
|
J2G5
|
J2GF
|
V7000, V5000, V3700, V3500 | |||||
2.5” SAS HDD 15K – 600GB |
ST600MP0005
|
B679
|
B67D
|
V7000, V5000, V3700, V3500 | |||||
2.5” SAS HDD 15K – 600GB |
ST600MP0006
|
B6A5
|
B6AB
|
V5000 G2, V7000 G2 | V5000 G2, FS 5100, V7000 G2, FS 7200, SVC | ||||
2.5” SAS HDD 10K – 300GB
|
ST9300603SS
|
B53B
|
B53E
|
V7000 | |||||
2.5” SAS HDD 10K – 300GB |
HUC106030CSS60
|
D216
|
D3A6
|
V7000 | |||||
2.5” SAS HDD 10K – 300GB |
ST9300605SS
|
B557
|
B55G
|
V7000 | |||||
2.5” SAS HDD 10K – 300GB |
HUC109030CSS60
|
J2E1
|
J2EG
|
V7000, V5000, V3700, V3500 | |||||
2.5” SAS HDD 10K – 300GB |
ST300MM0006
|
B56F
|
B56U
|
V7000, V3700, V3500 | |||||
2.5” SAS HDD 10K – 300GB |
HUC101830CSS20
|
J2H4
|
J2HD
|
V7000, V3700, V3500 | |||||
2.5” SAS HDD 10K – 300GB |
ST300MM0008
|
B585
|
B587
|
V7000, V3700, V3500 | |||||
2.5” SAS HDD 10K – 300GB | ST300MM0009 | B5B3 | B5B3 | V7000, V3700, V3500 | |||||
2.5” SAS HDD 10K – 300GB | AL15SEB030N | SB72 | SB75 | V7000, V3700, V3500 | |||||
2.5” SAS HDD 10K – 450GB
|
ST9450404SS
|
B546
|
B54A
|
V7000 | |||||
2.5” SAS HDD 10K – 450GB |
HUC106045CSS60
|
D216
|
D3A6
|
V7000 | |||||
2.5” SAS HDD 10K – 450GB |
ST9450405SS
|
B557
|
B55G
|
V7000 | |||||
2.5” SAS HDD 10K – 450GB |
ST450MM0006
|
B56F
|
B56U
|
V7000 | |||||
2.5” SAS HDD 10K – 450GB | HUC101845CSS20 | J2HD | J2HD | V7000 | |||||
2.5” SAS HDD 10K – 600GB
|
ST9600204SS
|
B546
|
B54A
|
V7000 | |||||
2.5” SAS HDD 10K – 600GB |
HUC106060CSS60
|
D216
|
D3A6
|
V7000 | |||||
2.5” SAS HDD 10K – 600GB |
ST9600205SS
|
B557
|
B55G
|
V7000 | |||||
2.5” SAS HDD 10K – 600GB |
HUC109060CSS60
|
J2E1
|
J2EG
|
V7000, V5000, V3700, V3500 | |||||
2.5” SAS HDD 10K – 600GB |
ST600MM0006
|
B56F
|
B56U
|
V7000, V5000, V3700, V3500 | |||||
2.5” SAS HDD 10K – 600GB |
HUC101860CSS20
|
J2H4
|
J2HD
|
V7000, V5000, V3700, V3500 | |||||
2.5” SAS HDD 10K – 600GB |
ST600MM0088
|
B589
|
B58A
|
V7000 G2 | V7000 G2, FS 7200 | ||||
2.5” SAS HDD 10K – 600GB | AL14SEB060N | SB43 | SB43 | V7000 G2 | V7000 G2, FS 7200 | ||||
2.5” SAS HDD 10K – 600GB | ST600MM0009 | B5B3 | B5BB | V7000 G2 | V7000 G2, FS 7200, SVC | ||||
2.5” SAS HDD 10K – 600GB | AL15SEB060N | SB72 | SB75 | V7000 G2 | V7000 G2, FS 7200 | ||||
2.5” SAS HDD 10K – 900GB
|
ST9900805SS
|
B557
|
B55G
|
V7000 | |||||
2.5” SAS HDD 10K – 900GB |
HUC109090CSS60
|
J2E1
|
J2EG
|
V7000, V5000, V3700, V3500 | |||||
2.5” SAS HDD 10K – 900GB |
ST900MM0006
|
B56F
|
B56U
|
V7000, V5000, V3700, V3500 | |||||
2.5” SAS HDD 10K – 900GB |
HUC101890CSS20
|
J2H4
|
J2HD
|
V7000, V5000, V3700, V3500 | |||||
2.5” SAS HDD 10K – 900GB |
ST900MM0168
|
B589
|
B58A
|
V5000 G2, V7000 G2 | V5000 G2, FS 5100, V7000 G2, FS7200, SVC | ||||
2.5” SAS HDD 10K – 900GB | AL14SEB090N | SB43 | SB43 | V5000 G2, V7000 G2 | V5000 G2, FS 5100, V7000 G2, FS 7200, SVC | ||||
2.5” SAS HDD 10K – 900GB | ST900MM0009 | B5B3 | B5BB | V50X0E, FS 50X0, FS 50X5 | V50X0E, FS 50X0, FS 50X5, FS 5200, FS 5300 | ||||
2.5” SAS HDD 10K – 900GB | AL15SEB090N | SB72 | SB75 | V5000 G2, V50X0E, FS 50X0, FS50X5, V7000 G2 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, SVC | ||||
2.5" SAS Tier 0 SSD - 3.2TB | MZILG3T2HBLA | SS82 | SS82 |
V5000 G2, V7000 G2
|
V5000 G2, FS 5100, V7000 G2, FS 7200, SVC | ||||
2.5" SAS Tier 0 SSD - 1.6TB | MZILG1T6HCLS | SS82 | SS82 |
V5000 G2, V7000 G2
|
V5000 G2, FS 5100, V7000 G2, FS 7200, SVC | ||||
2.5" SAS Tier 0 SSD - 800GB | MZILG800HCJR | SS82 | SS82 |
V5000 G2, V7000 G2
|
V5000 G2, FS 5100, V7000 G2, FS 7200, SVC | ||||
2.5" SAS Tier 0 SSD - 400GB | MZILG400HCHQ | SS82 | SS82 |
V5000 G2, V7000 G2
|
V5000 G2, FS 5100, V7000 G2, FS 7200, SVC | ||||
2.5" SAS Tier 1 SSD - 800GB | MZILG800HCHQ | SS82 | SS82 |
V5000 G2, V50X0E, FS 50X0, FS50X5, V7000 G2
|
V5000 G2, V50X0E, FS 50X0, FS50X5, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, SVC | ||||
2.5" SAS Tier 1 SSD - 30.72TB | MZILG30THBLA | SS82 | SS82 |
V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, V7000 G2
|
V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, FS 9100, FS 9200, FS 9500, SVC | ||||
2.5" SAS Tier 1 SSD - 15.36TB | MZILG15THBLA | SS82 | SS82 |
V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, V7000 G2
|
V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, FS V9000, FS 9100, FS 9200, FS 9500, SVC | ||||
2.5" SAS Tier 1 SSD - 7.68TB | MZILG7T6HBLA | SS82 | SS82 |
V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, V7000 G2
|
V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, FS V9000, FS 9100, FS 9200, FS 9500, SVC | ||||
2.5" SAS Tier 1 SSD - 3.84TB | MZILG3T8HCLS | SS82 | SS82 |
V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, V7000 G2
|
V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, FS V9000, FS 9100, FS 9200, FS 9500, SVC | ||||
2.5" SAS Tier 1 SSD - 1.92TB
|
MZILG1T9HCJR | SS82 | SS82 |
V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, V7000 G2
|
V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, FS V9000, FS 9100, FS 9200, FS 9500, SVC | ||||
3.5” NL SAS HDD 7.2K - 18TB | WUH722018BL420 | N6Z1 | N6Z1 |
FS 50X0, FS 50X5
|
FS 50X0, FS 50X5, FS 5100, FS 5200, FS 5300, FS 7200, FS 7300 | ||||
3.5” NL SAS HDD 7.2K - 20TB | WUH722020BL420 | N6Z1 | N6Z1 |
FS 50X5, FS 50X5 G2
|
FS 50X0, FS 50X5, FS 50X5 G2, FS 5200, FS 5300, FS 7300 | ||||
3.5” NL SAS HDD 7.2K - 18TB | ST18000NM003D | ECQ3 | ECQ5 |
FS 50X0, FS 50X5
|
FS 5100, FS 7200, FS 7300, FS 50X0, FS 5200 | ||||
3.5” NL SAS HDD 7.2K - 20TB | ST20000NM003D | ECQ3 | ECQ5 |
FS 50X5
|
FS 7300, FS 50X0, FS 5200 | ||||
2.5” NL SAS HDD 7.2K - 500GB
|
ST9500620SS | BD2A | BD2L | V7000, V3700, V3500 | |||||
2.5” NL SAS HDD 7.2K - 1TB
|
ST91000640SS
|
BD25
|
BD2L
|
V7000, V5000, V3700, V3500 | |||||
2.5” SAS HDD 10K - 1.2TB
|
HUC101212CSS60
|
J2M3
|
J2M8
|
V7000, V5000, V3700, V3500 | |||||
2.5” SAS HDD 10K - 1.2TB |
ST1200MM0007
|
B579
|
B57D
|
V7000, V5000, V3700, V3500 | |||||
2.5” SAS HDD 10K - 1.2TB |
HUC101812CSS20
|
J2H4
|
J2HD
|
V7000, V5000, V3700, V3500 | |||||
2.5” SAS HDD 10K - 1.2TB |
ST1200MM0088
|
B589
|
B58A
|
V5000 G2, V7000 G2 | V5000 G2, FS 5100, V7000 G2, FS7200, SVC, FS 9100, FS 9200 | ||||
2.5” SAS HDD 10K - 1.2TB | AL14SEB120N | SB43 | SB43 | V5000 G2, V7000 G2 | V5000 G2, FS 5100, V7000 G2, FS 7200, SVC | ||||
2.5” SAS HDD 10K - 1.2TB | ST1200MM0009 | B5B3 | B5BB | V50X0E, FS 50X0, FS 50X5, V7000 G2 | V50X0E, FS 50X0, FS 50X5, FS5200, FS 5300, V7000 G2, FS 7200, FS 7300, FS 9100, FS 9200, SVC | ||||
2.5” SAS HDD 10K - 1.2TB | AL15SEB120N | SB72 | SB75 | V5000 G2, V50X0E, FS 50X0, FS50X5, V7000 G2 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, FS 9100, FS 9200, SVC | ||||
2.5” SAS HDD 10K - 1.8TB
|
HUC101818CS420
|
J5H4
|
J5HB
|
v7.4.0.1
|
V7000, V5000, V3700, V3500 | ||||
2.5” SAS HDD 10K - 1.8TB |
ST1800MM0008
|
B5AA
|
B5AB
|
v7.4.0.1 | V5000 G2, V7000 G2 | V5000 G2, FS 5100, V7000 G2, FS 7200, SVC, FS 9100, FS 9200 | |||
2.5” SAS HDD 10K - 1.8TB | AL15SEB18EP | SB82 | SB85 | v7.4.0.1 | V5000 G2, V50X0E, FS 50X0, FS50X5, V7000 G2 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, FS 9100, FS 9200, SVC | |||
3.5” NL SAS HDD 7.2K - 2TB
|
ST32000444SS
|
BC26
|
BC2D
|
v6.2.0.5
|
V7000 | ||||
3.5” NL SAS HDD 7.2K - 2TB
|
ST2000NM0001
|
BC42
|
BC49
|
v6.2.0.5 | V7000 | ||||
3.5” NL SAS HDD 7.2K - 2TB
|
HUS723020ALS64
|
J26B
|
J3K5
|
v6.2.0.5 | V7000, V5000, V3700, V3500 | ||||
3.5” NL SAS HDD 7.2K - 2TB
|
ST2000NM0023
|
BC5C
|
BC5P
|
v6.2.0.5 | V7000, V5000, V3700, V3500 | ||||
3.5” NL SAS HDD 7.2K - 2TB
|
HUS724020ALS64
|
J3L9
|
J3L9
|
v6.2.0.5 | V7000 | ||||
3.5” NL SAS HDD 7.2K - 2TB | ST2000NM0045 | BC83 | BC83 | v6.2.0.5 | V7000, V5000, V3700, V3500 | ||||
3.5” NL SAS HDD 7.2K - 2TB | ST2000NM003A | BCJ3 | BCJ4 | v6.2.0.5 | NA | V7000 G2, FS 7200 | |||
3.5” NL SAS HDD 7.2K - 2TB | ST2000NM019B | KCM3 | KCM5 | v6.2.0.5 | NA | V7000 G2, FS 7200 | |||
3.5" NL SAS HDD 7.2K - 3TB
|
ST33000650SS
|
BC36
|
BC3E
|
v6.3.0.0
|
V7000, V3700, V3500 | ||||
3.5" NL SAS HDD 7.2K - 3TB
|
HUS723030ALS64
|
J26B
|
J3K5
|
v6.3.0.0 | V7000, V5000, V3700, V3500 | ||||
3.5" NL SAS HDD 7.2K - 3TB
|
ST3000NM0023
|
BC5C
|
BC5P
|
v6.3.0.0 | V7000, V5000, V3700, V3500 | ||||
3.5" NL SAS HDD 7.2K - 3TB
|
HUS724030ALS64
|
J3L9
|
J3L9
|
v6.3.0.0 | V7000, V5000, V3700, V3500 | ||||
3.5" NL SAS HDD 7.2K - 3TB | ST3000NM0025 | BC83 | BC83 | v6.3.0.0 | V7000, V5000, V3700, V3500 | ||||
3.5" NL SAS HDD 7.2K - 3TB | ST3000NM001A | BCJ3 | BCJ4 | v6.3.0.0 | NA | V7000 G2, FS 7200 | |||
3.5" NL SAS HDD 7.2K - 3TB | ST3000NM019B | KCM3 | KCM5 | v6.3.0.0 | NA | V7000 G2, FS 7200 | |||
3.5" NL SAS HDD 7.2K - 4TB
|
ST4000NM0023
|
BC5C
|
BC5P
|
v6.3.0.0 | V7000, V5000, V3700, V3500 | ||||
3.5" NL SAS HDD 7.2K - 4TB | ST4000NM0025 | BC83 | BC83 | v6.3.0.0 | V7000, V5000, V3700, V3500 | ||||
3.5" NL SAS HDD 7.2K - 4TB | HUS724040ALS64 | J3L9 | J3L9 | v6.3.0.0 | V7000, V5000, V3700, V3500 | ||||
3.5" NL SAS HDD 7.2K - 4TB | ST4000NM003A | BCJ3 | BCJ4 | v6.3.0.0 | NA | V7000 G2, FS 7200, SVC | |||
3.5" NL SAS HDD 7.2K - 4TB | ST4000NM019B | KCM3 | KCM5 | v6.3.0.0 | NA | V7000 G2, FS 7200, SVC | |||
3.5" NL SAS HDD 7.2K - 4TB 4Kn
|
ST4000NM0014 | BC78 | BC78 | V5000 | |||||
3.5" NL SAS HDD 7.2K - 4TB 4Kn | HUS726040AL421 | J6J1 | J6J5 | V5000 | |||||
3.5" NL SAS HDD 7.2K - 4TB 4Kn | ST4000NM0155 | BCC6 | BCC6 | V5000 | |||||
3.5" NL SAS HDD 7.2K - 4TB 4Kn | HUS726T4TAL420 | J6U4 | J6U4 | V5000 G2, V50X0E, FS 50X0, FS50X5 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS 5100, FS 5200, FS 5300 | ||||
3.5" NL SAS HDD 7.2K - 4TB 4Kn | ST4000NM004A | BCK5 | BCK8 | V5000 G2, V50X0E, FS 50X0, FS 50X5 | V5000 G2, V5000E, FS 50X0, FS 50X5, FS 5100, FS 5200, FS 5300 | ||||
3.5" NL SAS HDD 7.2K - 4TB 4Kn | ST4000NM031B | KCN1 | KCN4 | V5000 G2, V50X0E, FS 50X0, FS50X5 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS 5100, FS 5200, FS 5300 | ||||
3.5" NL SAS HDD 7.2K - 6TB
|
ST6000NM0014
|
BC73
|
BC7B
|
v7.4.0.1
|
V7000, V5000, V3700, V3500 | ||||
3.5" NL SAS HDD 7.2K - 6TB
|
HUS726060AL421
|
J6J1
|
J6J5
|
v7.4.0.1 | V7000, V5000, V3700, V3500 | ||||
3.5" NL SAS HDD 7.2K - 6TB | ST6000NM0105 | BCC6 | BCC6 | v7.4.0.1 | V7000, V5000, V3700, V3500 | ||||
3.5" NL SAS HDD 7.2K - 6TB | HUS726T6TAL420 | J6U4 | J6U4 | v7.4.0.1 | V5000 G2, V50X0E, FS 50X0, FS50X5 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, SVC | |||
3.5" NL SAS HDD 7.2K - 6TB | ST6000NM030A | BCK5 | BCK8 | v7.4.0.1 | V5000 G2, V50X0E, FS 50X0, FS 50X5 | V5000 G2, V50X0E, FS 50X0, FS 50X5, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, SVC | |||
3.5" NL SAS HDD 7.2K - 6TB | ST6000NM026B | KCN1 | KCN4 | v7.4.0.1 | V5000 G2, V50X0E, FS 50X0, FS50X5 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, SVC | |||
2.5” SAS Tier 0 SSD - 3200GB
|
ST3200FM0023
|
4C0D
|
4C1A
|
V5000 G2 | V5000 G2, FS 5100, V7000 G2, FS 7200, SVC | ||||
2.5” SAS Tier 0 SSD - 3200GB |
MTFDJAL3T2MBS
|
5C0D
|
5C1A
|
V7000, V5000, V3700, SVC | |||||
2.5” SAS Tier 0 SSD - 3200GB |
PX04SMB320
|
540F
|
540F
|
V5000 G2, V7000 G2 | V5000 G2, FS 5100, V7000 G2, FS 7200, SVC | ||||
2.5” SAS Tier 0 SSD - 3200GB | WUSTM3232ASS200 | J4V4 | J4V6 | V7000, V5000, SVC | |||||
2.5” SAS Tier 0 SSD - 3200GB | KPM6XMUG3T20 | S6E6 | S6E8 | V5000 G2, V7000 G2 | V5000 G2, FS 5100, V7000 G2, FS 7200, SVC | ||||
2.5” SAS Tier 0 SSD - 3200GB |
MZILT3T2HMLA |
MS3B | MS3E | V5000 G2, V7000 G2 | V5000 G2, FS 5100, V7000 G2, FS 7200, SVC | ||||
2.5” SAS Tier 0 SSD - 3200GB | XS3200ME70114 | 4391 | 4391 | V5000 G2, V7000 G2 | V5000 G2, FS 5100, V7000 G2, FS 7200, SVC | ||||
2.5” SAS Tier 1 SSD - 800GB | MZILT800HAJQ | MS3B | MS3E | V5000 G2, V7000 G2 | V5000 G2, FS 5100, V7000 G2, FS 7200, SVC | ||||
2.5” SAS Tier 1 SSD - 800GB | WUSTR6480ASS200 | J4V4 | J4V6 | v7.8.1.8 v8.1.3.4 v8.2.0.2 v8.2.1.0 | V7000, V5000, V9000, FS9100, FS9200, SVC | ||||
2.5” SAS Tier 1 SSD - 800GB | KPM6XVUG800G | S6E6 | S6E8 | v7.8.1.8 v8.1.3.4 v8.2.0.2 v8.2.1.0 | V5000 G2, V50X0E, FS 50X0, FS50X5, V7000 G2 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, SVC | |||
2.5” SAS Tier 1 SSD - 800GB | XS800LE70114 | 4391 | 4391 | v7.8.1.8 v8.1.3.4 v8.2.0.2 v8.2.1.0 | V5000E, FS 50X0, FS 50X5, V5000 G2, FS 5100 | V5000E, FS 50X0, FS 5200, V5000 G2, FS 5100, FS 7200, FS 7300, SVC | |||
2.5” SAS Tier 1 SSD - 2TB
|
PX04SRB192
|
540F
|
540F
|
v7.6.1.4
|
V5000 G2 | V5000 G2, FS 51000, V7000 G2, FS7200, FS 7300, SVC, FS V9000, FS 9100, FS 9200, FS 9500 | |||
2.5” SAS Tier 1 SSD - 2TB |
PX05SRB192
|
6402
|
6406
|
v7.6.1.4 |
NA
|
V7000 G2, FS 7200, FS 7300, SVC, FS V9000, FS 9100, FS 9200, FS 9500 | |||
2.5” SAS Tier 1 SSD - 2TB | KPM51RUG1T92 | S50A | S50A | v7.6.1.4 |
V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, V7000 G2
|
V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, FS V9000, FS 9100, FS 9200, FS 9500, SVC | |||
2.5” SAS Tier 1 SSD - 2TB | MZILS1T9HEJH | MS2A |
MS2A
|
v7.6.1.4 |
V5000 G2, V7000 G2
|
V5000 G2, FS 5100, V7000 G2, FS 7200, FS 7300, FS V9000, FS 9100, FS 9200, FS 9500, SVC | |||
2.5” SAS Tier 1 SSD - 2TB | XS1920SE10103 | 9399 | 939A | v7.6.1.4 | V5000 G2, V5000E, FS 50X0, FS 50X5, V7000 G2 | V5000 G2, FS 50X0, FS 5100, V5000E, FS 5200, V7000 G2, FS 7200, FS 7300, SVC, FS V9000, FS 9100, FS 9200, FS 9500 | |||
2.5” SAS Tier 1 SSD - 2TB | MZILT1T9HAJQ | MS3B | MS3E | v7.6.1.4 |
V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, V7000 G2
|
V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, FS V9000, FS 9100, FS 9200, FS 9500, SVC | |||
2.5” SAS Tier 1 SSD - 2TB |
HUSTR7619ASS200
|
J4U3 | J4U5 | v7.6.1.4 |
V7000, V5000,
V9000, FS9100, FS9200,
SVC
|
||||
2.5” SAS Tier 1 SSD - 2TB | WUSTR1519ASS200 | J4V4 | J4V6 | v7.6.1.4 |
V7000, V5000,
V9000, FS9100, FS9200,
SVC
|
||||
2.5” SAS Tier 1 SSD - 2TB | KPM6XRUG1T92 | S6E6 | S6E8 | v7.6.1.4 |
V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, V7000 G2
|
V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, FS V9000, FS 9100, FS 9200, FS 9500, SVC | |||
2.5” SAS Tier 1 SSD - 2TB |
|
4391 | 4391 | v7.6.1.4 |
V5000 G2, V7000 G2, V5000E, FS 50X0, FS 50X5
|
V5000 G2, FS 5100, V5000E, FS 50X0, FS 5200, V7000 G2, FS 7200, FS 7300, SVC, FS V9000, FS 9100, FS 9200, FS 9500 | |||
2.5” SAS Tier 1 SSD - 4TB
|
PX04SRB384
|
540F
|
540F
|
v7.6.1.4 | V5000 G2, V7000 G2 | V5000 G2, FS 51000, V7000 G2, FS7200, FS 7300, SVC, FS V9000, FS 9100, FS 9200, FS 9500 | |||
2.5” SAS Tier 1 SSD - 4TB |
PX05SRB384
|
6402
|
6406
|
v7.6.1.4 | V5000 G2, V7000 G2 | V5000 G2, FS 51000, V7000 G2, FS7200, FS 7300, SVC, FS V9000, FS 9100, FS 9200, FS 9500 | |||
2.5” SAS Tier 1 SSD - 4TB | MZILS3T8HMLH | MS2A | MS2A | v7.6.1.4 | V5000 G2, V7000 G2 | V5000 G2, FS 5100, V7000 G2, FS 7200, FS 7300, FS V9000, FS 9100, FS 9200, FS 9500, SVC | |||
2.5” SAS Tier 1 SSD - 4TB | XS3840SE10103 | 9399 | 939A | v7.6.1.4 | V5000 G2, V5000E, FS 50X0, FS 50X5, V7000 G2 | V5000 G2, FS 50X0, FS 5100, V5000E, FS 5200, V7000 G2, FS 7200, FS 7300, SVC, FS V9000, FS 9100, FS 9200, FS 9500 | |||
2.5” SAS Tier 1 SSD - 4TB | MZILT3T8HALS | MS3B | MS3E | v7.6.1.4 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, V7000 G2 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, FS V9000, FS 9100, FS 9200, FS 9500, SVC | |||
2.5” SAS Tier 1 SSD - 4TB |
HUSTR7638ASS200
|
J4U3 | J4U5 | v7.6.1.4 | V7000, V5000, V9000, FS9100, FS9200, SVC | ||||
2.5” SAS Tier 1 SSD - 4TB | WUSTR1538ASS200 | J4V4 | J4V6 | v7.6.1.4 | V7000, V5000, V9000, FS9100, FS9200, SVC | ||||
2.5” SAS Tier 1 SSD - 4TB | KPM51RUG3T84 | S50A | S50A | v7.6.1.4 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, V7000 G2 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, FS V9000, FS 9100, FS 9200, FS 9500, SVC | |||
2.5” SAS Tier 1 SSD - 4TB | KPM6XRUG3T84 | S6E6 | S6E8 | v7.6.1.4 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, V7000 G2 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, FS V9000, FS 9100, FS 9200, FS 9500, SVC | |||
2.5” SAS Tier 1 SSD - 4TB | XS3840SE70114 | 4391 | 4391 | v7.6.1.4 | V5000 G2, V5000E, FS 50X0, FS 50X5, V7000 G2 | V5000 G2, FS 5100, V5000E, FS 50X0, FS 5200, V7000 G2, FS 7200, FS 7300, SVC, FS V9000, FS 9100, FS 9200, FS 9500 | |||
2.5” SAS Tier 1 SSD - 7.6TB
|
MZILS7T6HMLS
|
MP05
|
MS1B
|
v7.6.1.4 | V5000 G2, V7000 G2 | V5000 G2, FS 5100, V7000 G2, FS 7200, FS 7300, FS V9000, FS 9100, FS 9200, FS 9500, SVC | |||
2.5” SAS Tier 1 SSD - 7.6 TB | XS7680SE70103 | 9399 | 939A | v7.6.1.4 | V5000 G2, V5000E, FS 50X0, FS 50X5, V7000 G2 | V5000 G2, FS 50X0, FS 5100, V5000E, FS 5200, V7000 G2, FS 7200, FS 7300, SVC, FS V9000, FS 9100, FS 9200, FS 9500 | |||
2.5” SAS Tier 1 SSD - 7.6 TB | MZILT7T6HMLA | MS3B | MS3E | v7.6.1.4 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, V7000 G2 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, FS V9000, FS 9100, FS 9200, FS 9500, SVC | |||
2.5” SAS Tier 1 SSD - 7.6 TB | HUSTR7676ASS200 | J4U5 | J4U5 | v7.6.1.4 | V7000, V5000, V9000, FS9100, FS9200, SVC | ||||
2.5” SAS Tier 1 SSD - 7.6 TB | WUSTR1576ASS200 | J4V4 | J4V6 | v7.6.1.4 | V7000, V5000, V9000, FS9100, FS9200, SVC | ||||
2.5” SAS Tier 1 SSD - 7.6 TB | KPM51RUG7T68 | S50A | S50A | v7.6.1.4 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, V7000 G2 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, FS V9000, FS 9100, FS 9200, FS 9500, SVC | |||
2.5” SAS Tier 1 SSD - 7.6 TB | KPM6XRUG7T68 | S6E6 | S6E8 | v7.6.1.4 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, V7000 G2 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, FS V9000, FS 9100, FS 9200, FS 9500, SVC | |||
2.5” SAS Tier 1 SSD - 7.6 TB | XS7680SE70114 | 4391 | 4391 | v7.6.1.4 | V5000 G2, V5000E, FS 50X0, FS 50X5, V7000 G2 | V5000 G2, FS 5100, V5000E, FS 50X0, FS 5200, V7000 G2, FS 7200, FS 7300, SVC, FS V9000, FS 9100, FS 9200, FS9 500 | |||
2.5” SAS Tier 1 SSD - 15.3 TB
|
MZILS15THMLS
|
MP05
|
MS1B
|
v7.6.1.4 | V5000 G2, V7000 G2 | V5000 G2, FS 5100, V7000 G2, FS 7200, FS 7300, FS V9000, FS 9100, FS 9200, FS 9500, SVC | |||
2.5” SAS Tier 1 SSD - 15.3 TB | MZILT15THMLA | MS3B | MS3E | v7.6.1.4 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, V7000 G2 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, FS V9000, FS 9100, FS 9200, FS 9500, SVC | |||
2.5” SAS Tier 1 SSD - 15.3 TB | WUSTR1515ASS200 | J4V4 | J4V6 | v7.6.1.4 | V7000, V5000, V9000, FS9100, FS9200, SVC | ||||
2.5” SAS Tier 1 SSD - 15.3 TB | KPM51RUG15T3 | S50A | S50A | v7.6.1.4 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, V7000 G2 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, FS V9000, FS 9100, FS 9200, FS 9500, SVC | |||
2.5” SAS Tier 1 SSD - 15.3 TB | KPM6XRUG15T3 | S6E6 | S6E8 | v7.6.1.4 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, V7000 G2 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, FS V9000, FS 9100, FS 9200, FS 9500, SVC | |||
2.5” SAS HDD 15K – 300GB
|
AL13SXB30EN
|
SC62
|
SC62
|
V7000, V5000 | |||||
2.5” SAS HDD 15K – 300GB | AL14SXB30EN | SC45 | SC48 | V7000, V5000 | |||||
2.5” SAS HDD 15K – 600GB
|
AL13SXB60EN
|
SC62
|
SC62
|
V7000, V5000 | |||||
2.5” SAS HDD 15K – 600GB | AL14SXB60EN | SC45 | SC48 | V7000, V5000 | |||||
2.5” SAS HDD 15K – 900GB
|
ST900MP0146
|
B6C4
|
B6CD
|
V5000 G2, V7000 G2 | V5000 G2, FS 5100, V7000 G2, FS 7200, SVC | ||||
2.5” SAS HDD 15K – 900GB | AL14SXB90EA | SC55 | SC58 | V7000, V5000 | |||||
2.5” SAS HDD 10K - 1.8TB
|
AL14SEB180EP
|
SB53
|
SB53
|
v7.4.0.1 | V5000 G2, V7000 G2 | V5000 G2, FS 5100, V7000 G2, FS 7200, SVC | |||
2.5” SAS HDD 10K - 1.8TB
|
ST1800MM0129
|
B5C1
|
B5CD
|
v7.4.0.1 | V5000 G2, V7000 G2 | V5000 G2, FS 5100, V50X0E, FS 50X0, FS 50X5, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, FS 9100, FS 9200, SVC | |||
2.5” SAS HDD 10K - 2.4TB
|
ST2400MM0129
|
B5C1
|
B5CD
|
v7.4.0.1 | V5000 G2, FS 50X5 G2, V7000 G2 | V5000 G2, FS 5100, V50X0E, FS 50X0, FS 50X5, FS 50X5 G2, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, FS 9100, FS 9200, SVC | |||
2.5” SAS HDD 10K - 2.4TB | AL15SEB24EP | SB82 | SB85 | v7.4.0.1 | V5000 G2, V50X0E, FS 50X0, FS50X5, V7000 G2 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, FS 9100, FS 9200, SVC | |||
2.5” NL SAS HDD 7.2K - 2TB
|
ST2000NX0263
|
BD44
|
BD4D
|
V7000, V5000, V3700, V3500 | |||||
3.5" NL SAS HDD 7.2K - 8TB
|
HUH728080AL420
|
J6P6
|
J6P6
|
v7.4.0.1 | V7000, V5000, V3700, V3500 | ||||
3.5" NL SAS HDD 7.2K - 8TB
|
HUH721008AL420
|
J6R2
|
J6R5
|
v7.4.0.1 |
V5000 G2
|
V5000 G2, FS 5100, V7000 G2, FS 7200, FS V9000, SVC | |||
3.5" NL SAS HDD 7.2K - 8TB
|
ST8000NM0065
|
BCE5
|
BCE6
|
v7.4.0.1 | V7000, V5000, V3700, V3500 | ||||
3.5" NL SAS HDD 7.2K - 8TB | HUS728T8TAL420 | J6V9 | J6V9 | v7.4.0.1 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, FS V9000, SVC | |||
3.5" NL SAS HDD 7.2K - 8TB | ST8000NM003A | BCK5 | BCK8 | v7.4.0.1 | V5000 G2, V50X0E, FS 50X0, FS 50X5 | V5000 G2, V50X0E, FS 50X0, FS 50X5, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, FS V9000, SVC | |||
3.5" NL SAS HDD 7.2K - 8TB | ST8000NM024B | KCN1 | KCN4 | v7.4.0.1 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, FS V9000, SVC | |||
3.5" NL SAS HDD 7.2K - 10TB
|
HUH721010AL420
|
J6R2
|
J6R5
|
v7.4.0.1 |
V5000 G2
|
V5000 G2, FS 5100, V7000 G2, FS 7200, FS V9000, SVC | |||
3.5" NL SAS HDD 7.2K - 10TB
|
ST10000NM0206 |
BCG8
|
BCGA | v7.4.0.1 |
V5000 G2
|
V5000 G2, FS 5100, V7000 G2, FS 7200, FS V9000, SVC | |||
3.5" NL SAS HDD 7.2K - 10TB | ST10000NM0528 | BCHB | BCHB | v7.4.0.1 | V5000 G2 | V5000 G2, FS 5100, V7000 G2, FS 7200, FS V9000, SVC | |||
3.5" NL SAS HDD 7.2K - 10TB | ST10000NM002G | BCL3 | BCL5 | v7.4.0.1 |
V5000 G2, V50X0E, FS 50X0, FS 50X5
|
V5000 G2, V50X0E, FS 50X0, FS 50X5, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, FS V9000, SVC | |||
3.5" NL SAS HDD 7.2K - 10TB | ST10000NM024B | KCN1 | KCN4 | v7.4.0.1 |
V5000 G2, V50X0E, FS 50X0, FS50X5
|
V5000 G2, V50X0E, FS 50X0, FS50X5, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, FS V9000, SVC | |||
3.5" NL SAS HDD 7.2K - 10TB SED |
ST10000NM014G |
ECP7 |
ECP7 |
v7.4.0.1 | V5000 G2, V50X0E, FS 50X0, FS50X5 | V5000 G2, FS 5100, V7000 G2, FS 7200, SVC, FS V9000, FS 7300, V50X0E, FS 50X0, FS 5200 | |||
3.5" NL SAS HDD 7.2K - 12TB SED |
ST12000NM005J |
ECP7 | ECP7 | v7.4.0.1 | V5000 G2, V50X0E, FS 50X0, FS50X5 | V5000 G2, FS 5100, V7000 G2, FS 7200, SVC, FS V9000, FS 7300, V50X0E, FS 50X0, FS 5200 | |||
3.5" NL SAS HDD 7.2K - 16TB SED |
ST16000NM005J |
ECP7 | ECP7 | v7.4.0.1 | V5000 G2, V50X0E, FS 50X0, FS50X5 | V5000 G2, FS 5100, V7000 G2, FS 7200, SVC, FS V9000, FS 7300, V50X0E, FS 50X0, FS 5200 | |||
3.5" NL SAS HDD 7.2K - 10TB |
ST10000NM015G |
KCP3 | KCP5 | v7.4.0.1 |
V5000 G2, V50X0E, FS 50X0, FS50X5
|
V5000 G2, V50X0E, FS 50X0, FS50X5, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, FS V9000, SVC | |||
3.5" NL SAS HDD 7.2K - 10TB | WUS721010AL420 | J6X3 | J6X3 | v7.4.0.1 |
V5000 G2, V50X0E, FS 50X0, FS50X5
|
V5000 G2, V50X0E, FS 50X0, FS50X5, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, FS V9000, SVC | |||
3.5" NL SAS HDD 7.2K - 10TB SED |
ST10000NM004G |
ECL6 |
ECL6 |
v7.4.0.1 |
V5000 G2
|
V5000G2, FS 5100, V7000 G2, FS 7200, SVC, V50X0E, FS 50X0, FS 5200 | |||
3.5" NL SAS HDD 7.2K - 14TB SED |
ST14000NM004G |
ECL6 |
ECL6 |
v7.4.0.1 |
V5000 G2, V50X0E, FS 50X0, FS50X5
|
V5000 G2, FS 5100, V7000 G2, FS 7200, SVC, FS V9000, FS 7300, V50X0E, FS 50X0, FS 5200 | |||
3.5" NL SAS HDD 7.2K - 16TB SED |
ST16000NM004G |
ECL6 |
ECL6 |
v7.4.0.1 |
V5000 G2, V50X0E, FS 50X0, FS50X5
|
V5000 G2, FS 5100, V7000 G2, FS 7200, SVC, FS V9000, FS 7300, V50X0E, FS 50X0, FS 5200 | |||
3.5" NL SAS HDD 7.2K - 12TB
|
HUH721212AL420
|
J6T4
|
J6T9 | v7.4.0.1 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, FS V9000, SVC | |||
3.5" NL SAS HDD 7.2K - 12TB | ST12000NM0038 | BCHB | BCHB | v7.4.0.1 |
V5000 G2
|
V5000 G2, FS 5100, V7000 G2, FS 7200, FS V9000, SVC | |||
3.5" NL SAS HDD 7.2K - 12TB | ST12000NM002G | BCL3 | BCL5 | v7.4.0.1 |
V5000 G2, V50X0E, FS 50X0, FS 50X5, FS 50X5 G2
|
V5000 G2, V50X0E, FS 50X0, FS 50X5, FS 50X5 G2, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, FS V9000, SVC | |||
3.5" NL SAS HDD 7.2K - 12TB | ST12000NM006J | KCP3 | KCP5 | v7.4.0.1 |
V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2
|
V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, FS V9000, SVC | |||
3.5" NL SAS HDD 7.2K - 14TB | ST14000NM0048 | BCHB | BCHB | v7.4.0.1 |
V5000 G2
|
V5000 G2, FS 5100, V7000 G2, FS 7200, SVC | |||
3.5" NL SAS HDD 7.2K - 14TB | ST14000NM002G | BCL3 | BCL5 | v7.4.0.1 |
V5000 G2, V50X0E, FS 50X0, FS 50X5
|
V5000 G2, V50X0E, FS 50X0, FS 50X5, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, SVC | |||
3.5" NL SAS HDD 7.2K - 16TB | ST16000NM002G | BCL3 | BCL5 | v7.4.0.1 |
V5000 G2, V50X0E, FS 50X0, FS 50X5, FS 50X5 G2
|
V5000 G2, V50X0E, FS 50X0, FS 50X5, FS 50X5 G2, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, FS V9000, SVC | |||
3.5" NL SAS HDD 7.2K - 14TB | ST14000NM006J | KCP3 | KCP5 | v7.4.0.1 |
V5000 G2, V50X0E, FS 50X0, FS50X5
|
V5000 G2, V50X0E, FS 50X0, FS50X5, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, SVC | |||
3.5" NL SAS HDD 7.2K - 14TB | WUH721414AL420 | J6W3 | J6W3 | v7.4.0.1 |
V5000 G2, V50X0E, FS 50X0, FS50X5
|
V5000 G2, V50X0E, FS 50X0, FS50X5, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, SVC | |||
3.5" NL SAS HDD 7.2K - 16TB | WUH721816AL420 | J6Y5 | J6Y5 | v7.4.0.1 |
V50X0E, FS 50X0, FS50X5, FS50X5 G2
|
V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, FS V9000, SVC | |||
3.5" NL SAS HDD 7.2K - 16TB | ST16000NM006J | KCP3 | KCP5 | v7.4.0.1 |
V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2
|
V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, FS V9000, SVC | |||
3.5" NL SAS HDD 7.2K - 18TB | WUH721818AL420 | J6Y5 | J6Y5 | v7.4.0.1 |
FS 50X0, FS50X5
|
FS 50X0, FS50X5, FS 5100, FS 5200, FS 5300, FS 7200, FS 7300 | |||
3.5" NL SAS HDD 7.2K - 18TB | ST18000NM006J | KCP3 | KCP5 | v7.4.0.1 |
FS 50X0, FS50X5
|
FS 50X0, FS50X5, FS 5100, FS 5200, FS 5300, FS 7200, FS 7300 | |||
2.5” SAS Tier 0 SSD - 200GB | MZILT200HBHQ | MS71 | MS74 |
V7000, V5000, V3700,SVC
|
|||||
2.5” SAS Tier 0 SSD - 400GB | MZILT400HBHQ | MS71 | MS74 | V5000 G2, V7000 G2 | V5000 G2, FS 5100, V7000 G2, FS 7200, SVC | ||||
2.5” SAS Tier 0 SSD - 800GB | MZILT800HBJR | MS71 | MS74 | V5000 G2, V7000 G2 | V5000 G2, FS 5100, V7000 G2, FS 7200, SVC | ||||
2.5” SAS Tier 0 SSD - 1.6TB | MZILT1T6HBLS | MS71 | MS74 | V5000 G2, V7000 G2 | V5000 G2, FS 5100, V7000 G2, FS 7200, SVC | ||||
2.5” SAS Tier 0 SSD - 3.2TB | MZILT3T2HALA | MS71 | MS74 | V5000 G2, V7000 G2 | V5000 G2, FS 5100, V7000 G2, FS 7200, SVC | ||||
2.5” SAS Tier 1 SSD - 800GB | MZILT800HBHQ | MS71 | MS74 | V5000 G2, V50X0E, FS 50X0, FS50X5, V7000 G2 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS 5100, FS 5200, FS 5300, V7000 G2, SVC | ||||
2.5” SAS Tier 1 SSD - 1.9TB | MZILT1T9HBJR | MS71 | MS74 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, V7000 G2 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, FS V9000, FS 9100, FS 9200, FS 9500, SVC | ||||
2.5” SAS Tier 1 SSD - 3.8TB | MZILT3T8HBLS | MS71 | MS74 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, V7000 G2 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, FS V9000, FS 9100, FS 9200, FS 9500, SVC | ||||
2.5” SAS Tier 1 SSD - 7.6TB | MZILT7T6HALA | MS71 | MS74 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, V7000 G2 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, FS V9000, FS 9100, FS 9200, FS 9500, SVC | ||||
2.5” SAS Tier 1 SSD - 15.36 TB | MZILT15THALA | MS71 | MS74 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, V7000 G2 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, FS V9000, FS 9100, FS 9200, FS 9500, SVC | ||||
2.5” SAS Tier 1 SSD - 30.72TB |
MZILT30THMLA |
MS3B |
MS3E |
V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, V7000 G2 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, FS V9000, FS 9100, FS 9200, FS 9500, SVC | ||||
2.5” SAS Tier 1 SSD - 30.72TB | MZILT30THALA | MS71 | MS74 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, V7000 G2 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, FS V9000, FS 9100, FS 9200, FS 9500, SVC | ||||
2.5” SAS Tier 1 SSD - 30.72TB | KPM6XRUG30T7 | S6E6 | S6E8 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, V7000 G2 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, FS V9000, FS 9100, FS 9200, FS 9500, SVC | ||||
2.5” SAS Tier 1 SSD - 1.9TB |
KPM7VRUG1T92 |
S7S3 | S7S3 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, V7000 G2 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, FS V9000, FS 9100, FS 9200, FS 9500, SVC | ||||
2.5” SAS Tier 1 SSD - 3.8TB |
KPM7VRUG3T84 |
S7S3 | S7S3 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, V7000 G2 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, FS V9000, FS 9100, FS 9200, FS 9500, SVC | ||||
2.5” SAS Tier 1 SSD - 7.6TB |
KPM7VRUG7T68 |
S7S3 | S7S3 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, V7000 G2 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, FS V9000, FS 9100, FS 9200, FS 9500, SVC | ||||
2.5” SAS Tier 1 SSD - 15.3TB |
KPM7VRUG15T3 |
S7S3 | S7S3 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, V7000 G2 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, FS V9000, FS 9100, FS 9200, FS 9500, SVC | ||||
2.5” SAS Tier 1 SSD - 30.72TB |
KPM7VRUG30T7 |
S7S3 | S7S3 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, V7000 G2 | V5000 G2, V50X0E, FS 50X0, FS50X5, FS50X5 G2, FS 5100, FS 5200, FS 5300, V7000 G2, FS 7200, FS 7300, FS V9000, FS 9100, FS 9200, FS 9500, SVC | ||||
2.5" NVMe Tier 1 SSD - 1.9TB | 101406EF | SNAASNAA | SNAASNAA | V5100, FS 5100, FS 5200, FS 5300, V7000 G3, FS 7200, FS 7300, FS 9100, FS 9200, FS 9500 | NA | ||||
2.5" NVMe Tier 1 SSD - 3.8TB | 10140700 | SNAASNAA | SNAASNAA | V5100, FS 5100, FS 5200, FS 5300, V7000 G3, FS 7200, FS 7300, FS 9100, FS 9200, FS 9500 | NA | ||||
2.5" NVMe Tier 1 SSD - 7.6TB | 10140701 | SNAASNAA | SNAASNAA | V5100, FS 5100, FS 5200, FS 5300, V7000 G3, FS 7200, FS 7300, FS 9100, FS 9200, FS 9500 | NA | ||||
2.5" NVMe Tier 1 SSD - 15.3TB | 10140702 | SNAASNAA | SNAASNAA | V5100, FS 5100, FS 5200, FS 5300, V7000 G3, FS 7200, FS 7300, FS 9100, FS 9200, FS 9500 | NA | ||||
2.5" NVMe Tier 1 SSD - 1.9TB | 101406D4 | C8S4 | C8S4 | V5100, FS 5100, FS 5200, FS 5300, V7000 G3, FS 7200, FS 7300, FS 9100, FS 9200, FS 9500 | NA | ||||
2.5" NVMe Tier 1 SSD - 3.8TB | 101406D5 | C8S4 | C8S4 | V5100, FS 5100, FS 5200, FS 5300, V7000 G3, FS 7200, FS 7300, FS 9100, FS 9200, FS 9500 | NA | ||||
2.5" NVMe Tier 1 SSD - 7.6TB | 101406D6 | C8S4 | C8S4 | V5100, FS 5100, FS 5200, FS 5300, V7000 G3, FS 7200, FS 7300, FS 9100, FS 9200, FS 9500 | NA | ||||
2.5" NVMe Tier 1 SSD - 15.36TB | 101406D7 | C8S4 | C8S4 | ||||||
2.5" NVMe Tier 1 SSD - 30.72TB | 101406D8 | C8S4 | C8S4 | FS 5200, FS 5300, FS 7300, FS 9500 | NA |
IBM Storage Virtualize controller | Search Abbreviation |
---|---|
IBM FlashSystem 5015, FlashSystem 5035, FlashSystem 5045, FlashSystem 5200 | FS5015. FS5035, FS5045, FS5200 |
IBM Storwize V7000 (2067), V7000 Unified (2073), FlashSystem 7200,FlashSystem 7300 | V7000, FS7200, FS7300 |
IBM FlashSystem V9000, FlashSystem 9100, FlashSystem 9200, FlashSystem 9500 | V9000, FS9100, FS9200, FS9500 |
SAN Volume Controller | SVC |
Related Information
[{"Line of Business":{"code":"LOB26","label":"Storage"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"ST3FR7","label":"IBM Storwize V7000"},"ARM Category":[{"code":"","label":""}],"Platform":[{"code":"","label":"Platform Independent"}],"Version":"Version Independent"},{"Line of Business":{"code":"LOB26","label":"Storage"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"ST5Q4U","label":"IBM Storwize V7000 Unified (2073)"},"ARM Category":[{"code":"","label":""}],"Platform":[{"code":"","label":"Platform Independent"}],"Version":"Version Independent"},{"Line of Business":{"code":"LOB26","label":"Storage"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"STLM6B","label":"IBM Storwize V3500 (2071)"},"ARM Category":[{"code":"","label":""}],"Platform":[{"code":"","label":"Platform Independent"}],"Version":"Version Independent"},{"Line of Business":{"code":"LOB26","label":"Storage"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"STLM5A","label":"IBM Storwize V3700 (2072)"},"ARM Category":[{"code":"","label":""}],"Platform":[{"code":"","label":"Platform Independent"}],"Version":"Version Independent"},{"Line of Business":{"code":"LOB26","label":"Storage"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"STHGUJ","label":"IBM Storwize V5000"},"ARM Category":[{"code":"","label":""}],"Platform":[{"code":"","label":"Platform Independent"}],"Version":"Version Independent"},{"Line of Business":{"code":"LOB26","label":"Storage"},"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"STKMQV","label":"IBM FlashSystem V9000"},"ARM Category":[{"code":"","label":""}],"Platform":[{"code":"","label":"Platform Independent"}],"Version":"Version Independent"},{"Line of Business":{"code":"LOB26","label":"Storage"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"STPVGU","label":"SAN Volume Controller"},"ARM Category":[{"code":"","label":""}],"Platform":[{"code":"","label":"Platform Independent"}],"Version":"Version Independent"},{"Line of Business":{"code":"LOB26","label":"Storage"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"ST3FR9","label":"IBM FlashSystem 5000"},"ARM Category":[{"code":"a8m0z000000bqPqAAI","label":"Documentation"}],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"All Version(s)","Type":"MASTER"},{"Type":"MASTER","Line of Business":{"code":"LOB26","label":"Storage"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"ST2HTZ","label":"IBM FlashSystem Software"},"ARM Category":[{"code":"a8m0z000000bqPqAAI","label":"Documentation"}],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"All Version(s)"},{"Type":"MASTER","Line of Business":{"code":"LOB26","label":"Storage"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"ST3FR9","label":"IBM FlashSystem 5x00"},"ARM Category":[{"code":"a8m0z000000bqPqAAI","label":"Documentation"}],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"All Version(s)"},{"Type":"MASTER","Line of Business":{"code":"LOB26","label":"Storage"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSA76Z4","label":"IBM FlashSystem 7x00"},"ARM Category":[],"ARM Case Number":[],"Platform":[{"code":"PF025","label":"Platform Independent"}]},{"Type":"MASTER","Line of Business":{"code":"LOB26","label":"Storage"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"STSLR9","label":"IBM FlashSystem 9x00"},"ARM Category":[{"code":"a8m0z000000bqPqAAI","label":"Documentation"}],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"All Version(s)"},{"Type":"MASTER","Line of Business":{"code":"LOB26","label":"Storage"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"STSLR9","label":"IBM FlashSystem 9x00"},"ARM Category":[{"code":"a8m0z000000bqPqAAI","label":"Documentation"}],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"All Version(s)"}]
Was this topic helpful?
Document Information
Modified date:
19 December 2024
UID