Troubleshooting
Problem
When logging into a BNT Virtual Fabric 10 Gigabit Switch Module for IBM BladeCenter, Option part number 46C7191, or a BNT 1/10 Gigabit Uplink Ethernet Switch Module for IBM BladeCenter, Option part number 44W4404, the user is presented the following prompt: Select Command Line Interface mode (ibmnos-cli/iscli): The user cannot choose "ibmnos-CLI". Only iscli can be chosen. This is seen running both firmware versions 6.8.1 and 6.8.6.
Resolving The Problem
Source
RETAIN tip: H205417
Symptom
When logging into a BNT Virtual Fabric 10 Gigabit Switch Module for IBM BladeCenter, Option part number 46C7191, or a BNT 1/10 Gigabit Uplink Ethernet Switch Module for IBM BladeCenter, Option part number 44W4404, the user is presented the following prompt:
Select Command Line Interface mode (ibmnos-cli/iscli): |
The user cannot choose "ibmnos-CLI". Only iscli can be chosen. This is seen running both firmware versions 6.8.1 and 6.8.6.
The following example uses the BNT Virtual Fabric 10 Gigabit Switch Module.
IBM Networking operating system Virtual Fabric 10 Gigabit Switch Module for IBM BladeCenter. Enter password: Select Command Line Interface mode (ibmnos-cli/iscli): Select Command Line Interface mode (ibmnos-cli/iscli): ibmnos-cli Ambiguous selection! Select Command Line Interface mode (ibmnos-cli/iscli): Select Command Line Interface mode (ibmnos-cli/iscli): iscli System Information at 15:12:29 Thu Mar 15, 2012 Time zone: America/US/Pacific Daylight Savings Time Status: Disabled IBM Networking operating system Virtual Fabric 10 Gigabit Switch Module for IBM BladeCenter Switch has been up for 2 days, 22 hours, 18 minutes and 15 seconds. Last boot: (power cycle) MAC Address: 08:17:f4:30:12:00 Management IP Address (if 128): 10.240.24.133 Software Version 6.8.1.0 (FLASH image1), active configuration. PCBA Part Number: BAC-00042-00 Hardware Part Number: 46C7193 FAB Number: BN-JNC Serial Number: Y253VT11H402 Manufacturing Date: 04/11 Hardware Revision: 4 Board Revision: 5 PLD Firmware Version: 5.0 ... az1ecmlpsc05-bnt1> |
Affected configurations
The system is configured with one or more of the following IBM Options:
- BNT 1/10 Gigabit Uplink Ethernet Switch Module for IBM BladeCenter, Option part number 44W4404, replacement part number (FRU) 44W4407
- BNT Virtual Fabric 10 Gigabit Switch Module for IBM BladeCenter, Option part number 46C7191, replacement part number (FRU) 46C7194
This tip is not system specific.
This tip is not software specific.
Solution
This behavior will be corrected in a future release of the switch firmware.
The target date for this release is scheduled for second quarter 2012.
The file is or will be available by selecting the appropriate Product group, System, Product name, Product machine type, and operating system on IBM Support's Fix Central web page, at the following URL:
Workaround
Choose from one of the following two (2) workarounds:
Workaround 1
Force the use of ibmnos-CLI at switch boot. In the switch Graphical User Interface (GUI):
- Select Configure at top of screen.
- Expand the menu in the left window pane.
- Select Config/Image Control from the expanded menu.
- In the main windowpane (on right) select IBMoperating system CLI for "Next CLI Boot Mode Selection."
- Select DISABLE for "Prompt for selectable boot mode."
Workaround 2
Type "IBM" (instead of ibmnos-CLI) at the Select Command Line Interface mode (ibmnos-CLI/iscli): prompt.