A system equipped with the LSI1030 chipset for a SCSI solution might display prolonged drive activity even though there is no activity at the operating system level. This behavior is exhibited about every three months (90 days). The activity LED of the drives indicate that the drives are actively working and processing I/O.
Source
RETAIN tip: H183934
Symptom
A system equipped with the LSI1030 chipset for a SCSI solution
might display prolonged drive activity even though there is no
activity at the operating system level. This behavior is exhibited
about every three months (90 days). The activity LED of the drives
indicate that the drives are actively working and processing
I/O.
Affected configurations
The system may be any of the following IBM eServer systems:
- IBM BladeCenter HS40, type 8839, any model
- IBM BladeCenter HS20, type 8678, any model
- IBM BladeCenter HS20, type 8843, any model
- IBM BladeCenter HS20, type 8832, any model
- IBM 326, type 8848, any model
- IBM 325, type 8835, any model
- IBM xSeries 455, type 8855, any model
- IBM xSeries 450, type 8688, any model
- IBM xSeries 445, type 8870, any model
- IBM xSeries 382, type 8834, any model
- IBM xSeries 365, type 8862, any model
- IBM xSeries 365, type 8861, any model
- IBM xSeries 345, type 8670, any model
- IBM xSeries 336, type 8837, any model
- IBM xSeries 336, type 8838, any model
- IBM xSeries 335, type 8830, any model
- IBM xSeries 335, type 8676, any model
- IBM xSeries 235, type 8671, any model
- IBM xSeries 225, type 8649, any model
- IBM xSeries 225, type 8647, any model
The system may be any of the following IBM IntelliStation
workstations:
- an IBM IntelliStation Z Pro, type 6221, any model
The system is configured with one or more of the following:
- IBM BladeCenter SCSI Storage Expansion Unit, option part number
(p/n) 26K4847, field replacement unit (FRU) 26K4851
- IBM BladeCenter HS20 SCSI Storage Expansion Unit, option p/n
48P7058, FRU 59P6616
- IBM BladeCenter SCSI Storage Expansion Unit, option p/n
26K4817, FRU 13N2366
Solution
This behavior will be corrected in a future release of LSI BIOS.
The target date for the release is scheduled for: 3rd Quarter,
2005. It will be available from the IBM xSeries support Web site,
at the following URL: http://www.ibm.com/systems/support/x
Workaround
By deleting and recreating the mirrored drives, the problem is
eliminated for the next 90 days. After 90 days, the problem will
recur. In order to recreate the mirror:
- Reboot the system.
- Enter the LSI BIOS setup utility by pressing
Ctrl+C when prompted.
- Select the LSI1030 controller where the mirror is located.
- Select <RAID Properties>
- Write down which device is the Primary device and which
one is the Secondary.
- Select <Delete Array>
- Select <Save changes. Exit menu>
- Select the LSI1030 controller where the mirror was
located.
- Select <RAID Properties>
- Select the primary drive and press the '+' key to
add it as the primary.
- Note: *IMPORTANT*: Press 'F3' to keep the
data.
- Select the secondary drive and press the '+' key
to add it as the secondary.
- Press the Del key. The data on the secondary will be
overwritten with the data on the primary. This is OK since previous
to deleting the mirror, the data on both drives was the same.
- Press the Esc key, and select <Save changes. Exit
menu>. The drives will begin synchronizing immediately, this
is normal. After the synchronization is complete, the system will
return to optimal operation.
Additional information
The symptoms seen are very similar to drive activity during a
synchronization, although none of the reporting tools show the
drives as being synchronized. System performance might be impacted
because of the constant disk activity. The symptoms are seen after
about three months and it's because of a problem in the datascrub
code. Datascrub is a background operation that periodically checks
the status of the mirror by reading and verifying data in the
mirrored set. Datascrub is programmed to scan the entire volume
once every 90 days. The problem in the datascrub code manifests
itself exactly during the last access operation of the datascrub.
This causes a read error which schedules a looping background
synchronization. By deleting and recreating the volume, the
datascrub will be reset.
IntelliStation Pro:Red Hat Linux
System x Hardware Options:Red Hat Linux
Older System x:Red Hat Linux
BladeCenter:Red Hat Enterprise Linux 3
BladeCenter:Red Hat Enterprise Linux 4
BladeCenter:Red Hat Enterprise Linux 5
Older System x:Red Hat Enterprise Linux 3
Older System x:Red Hat Enterprise Linux 4
Older System x:Red Hat Enterprise Linux 5
[{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW19P","label":"Older System x->xSeries 235"},"Platform":[{"code":"PF042","label":"Caldera"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW19R","label":"Older System x->xSeries 335"},"Platform":[{"code":"PF042","label":"Caldera"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW19S","label":"Older System x->xSeries 345"},"Platform":[{"code":"PF042","label":"Caldera"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW19T","label":"Older System x->xSeries 225"},"Platform":[{"code":"PF042","label":"Caldera"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW19U","label":"Older System x->xSeries 445"},"Platform":[{"code":"PF042","label":"Caldera"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW19W","label":"Older System x->xSeries 450"},"Platform":[{"code":"PF042","label":"Caldera"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW20A","label":"Older System x->xSeries 382"},"Platform":[{"code":"PF042","label":"Caldera"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW20C","label":"Older System x->eServer 325"},"Platform":[{"code":"PF042","label":"Caldera"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW20E","label":"Older System x->xSeries 365"},"Platform":[{"code":"PF042","label":"Caldera"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW20P","label":"Older System x->xSeries 336"},"Platform":[{"code":"PF042","label":"Caldera"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW20S","label":"Older System x->eServer 326"},"Platform":[{"code":"PF042","label":"Caldera"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU056","label":"Miscellaneous"},"Product":{"code":"HW19V","label":"BladeCenter HS20"},"Platform":[{"code":"PF042","label":"Caldera"}],"Line of Business":{"code":"LOB18","label":"Miscellaneous LOB"}},{"Type":"HW","Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"QU00NZF","label":"IntelliStation Pro->IntelliStation Z Pro->6221"},"Platform":[{"code":"PF042","label":"Caldera"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU056","label":"Miscellaneous"},"Product":{"code":"HW19V","label":"BladeCenter HS20"},"Platform":[{"code":"PF042","label":"Caldera"}],"Line of Business":{"code":"LOB18","label":"Miscellaneous LOB"}},{"Type":"HW","Business Unit":{"code":"BU056","label":"Miscellaneous"},"Product":{"code":"HW20G","label":"BladeCenter HS40"},"Platform":[{"code":"PF042","label":"Caldera"}],"Line of Business":{"code":"LOB18","label":"Miscellaneous LOB"}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QU00UKC","label":"System x Hardware Options->Storage expansion->SCSI->26K4847"},"Platform":[{"code":"PF042","label":"Caldera"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU056","label":"Miscellaneous"},"Product":{"code":"HW19V","label":"BladeCenter HS20"},"Platform":[{"code":"PF042","label":"Caldera"}],"Line of Business":{"code":"LOB18","label":"Miscellaneous LOB"}},{"Type":"HW","Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"QU01BAD","label":"System x Hardware Options->Storage expansion->SCSI->26K4817"},"Platform":[{"code":"PF042","label":"Caldera"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"QU01VGE","label":"System x Hardware Options->Storage expansion->SCSI->48P7058"},"Platform":[{"code":"PF042","label":"Caldera"}],"Line of Business":{"code":"","label":""}}]