IBM Support

(Critical update) IBM ServeRAID MR10il SAS Controller firmware v11.0.1-0008 (DOS) - IBM System x3610 (7942)

Download


Version

11.0.1-0008

Release Date

30 June 2009

Downloadable File

File link File size File description
4,379 README for the IBM ServeRAID MR10il SAS Controller Firmware Update DOS Diskettes
10,407 CHANGE HISTORY for the IBM ServeRAID MR10il SAS Controller Firmware Update DOS Diskettes
1,474,560 IBM ServeRAID MR10il SAS Controller Firmware Update DOS Diskette (1 of 3)
1,474,560 IBM ServeRAID MR10il SAS Controller Firmware Update DOS Diskette (2 of 3)
1,474,560 IBM ServeRAID MR10il SAS Controller Firmware Update DOS Diskette (3 of 3)

Abstract

Download the latest IBM ServeRAID MR10il SAS Controller Firmware DOS Diskettes for the IBM System x3610 (7942)

Download Description

Severity: Critical update

Supported Adapters: IBM ServeRAID MR10il SAS Controller (44E8767)

Change history

NOTE TO SERVICE - Reference RETAIN tips: H194224, H194505, H194171

Version 11.0.1-0008 - Critical update

Fixes:

  • Fixed an issue which could result in incorrect data on the drives after heavy I/O. (RETAIN tip H194224)
  • Fixed an issue where, if medium errors are experienced while a background operation is running, incorrect data could be written to the drives. (RETAIN tip H194505)
  • Changed the warning message that appears when the card goes in to temporary write through mode. (RETAIN tip H194171)
  • Fixed an error where erroneous Bad Battery messages were displayed even after a Learn Cycle was performed.
  • Fixed an issue that resulted in SERRs on a ServeRAID-MR10M controller.
  • Improved the handling of bad cable scenarios which could cause system hangs.

Functionality:

  • Added support for UEFI based systems.
  • Added support for Solid State Drives (SSDs).
  • Added tape support for the ServeRAID 10ie (CIOv) controller.
  • Added the ability to handle SGPIO and SES signalling on a per-port basis to handle configurations with both direct attached and expander attached drives on a single controller.
  • Added a field to show hard drive model names in WebBIOS.

Version 9.0.1-0030

Fixes:

  • Fixed an issue where, if a battery was fully discharged and was reported as 'missing', a reboot was be required before the battery would be detected as 'charging'.
  • Fixed an issue where a hotspare was reported as unconfirmed good after replacement.
  • Fixed an issue where an invalid alert 2121 was logged when a virtual drive was created.
  • Display and log a warning message when a consistency check is started on an uninitialized logical drive.
  • Fixed an issue where the message "SES enclosure 1 Recovered after fault" would be logged, after which the discovery process would take a very long time.
  • Fixed an issue where the multipath enclosure IDs were not updated correctly when an ESM or a drive was pulled and reinserted.
  • Fixed an issue where, if a unconfigured drive was pulled and reinserted, the size of the drive would be reported incorrectly.
  • Fixed an issue where a dedicated hotspare would become a global hotspare. This could happen after a migration or, in some circumstances, after a system reboot.
  • Fixed an issue where the firmware could hang when trying to view hotspare information under CTRL+R.
  • Fixed an issue where a rebuild would not start when a new drive was inserted.
  • Fixed an issue where a logical drive is still shown as optimal after a drive was pulled.
  • Fixed a critical firmware error that occurred when a physical drive was pulled from a RAID10 or RAID1E during heavy I/O.
  • Fixed an issue where a hang could occur when an ESM was removed.
  • Fixed an issue where, if multiple physical drives are pulled from an enclosure, additional drives might be lost. This could lead to incorrect data on the disks.
  • Fixed an issue where reconfiguring a virtual disk by adding a drive, or similar activity, will cause a dedicated hotspare to become unassociated.
  • Fixed an issue where a success code was incorrectly returned when data was sent to a failed drive. This could cause a loss of data.
  • Fixed an issue where, if additional drives failed in a virtual disk while a rebuild was happening, the system could hang.
  • Fixed an issue where daisy-chained enclosures would all be reported with the same position number. Also fixed a related issue where 'locate' did not function properly for daisy-chained enclosures.
  • Fixed an issue where the controller could hang if diagnostics were run while a rebuild was happening.
  • Fixed an issue where hotspares were lost during configuration import.
  • Fixed an issue where, if two enclosures were configured and the cable was pulled from each, then reattached in a swapped configuration, the system would hang on boot.
  • Fixed an issue where successive power cycles in a multi-enclosure configuration could result in offline drives or a system hang.
  • Fixed an issue where, with the controller mux set to 'Auto', configuration would be lost during reboot.
  • Fixed an issue where rebuilds might fail to resume after enclosure power is restored.
  • Corrected several issue where the consistency check was not properly handling double medium errors.
  • Ensured that BGI (Background Initialization) setting was retained during foreign configuration import.
  • Fixed an issue which caused MSM to not allow creation of additional virtual disks once 16 virtual disks existed.
  • Fixed an issue that caused a hang if a rebuild was in progress when a configuration was migrated from an IR to an MR controller.
  • Fixed an issue where load balancing would not resume properly after a cable pull.
  • Fixed an issue where, during a target or chip reset, the Disk Write Cache setting on a SATA drive would be reset to default, which is generally 'enabled'.
  • Fixed an issue where, when BGI is aborted, the status for the CC (consistency check), rather than the status for the BGI, is reported.
  • Fixed an issue where, if a physical disk fails, causing a logical drive to become degraded, trying to clear or change the configuration would result in a hang until the failed drive was physically removed.
  • Fixed a hang that was seen when a cable was pulled just before system shutdown.
  • Ensured that a hotspare would revert back to hotspare state after a rebuild to that hotspare failed.
  • Fixed several issue that could cause "Illegal Request Sense Data" messages.
  • Fixed an issue where a rebuild would hang if one of the logical drives on the array was deleted during the rebuild.
  • Fixed an issue which could result in incorrect data in a scenario where RAID 50 arrays are running in a degraded state for an extended period of time.
  • Fixed several issues where medium errors could result in offline drives, incorrect data on drives, failed rebuilds, or system hangs.
  • Fixed an issue where, when a redundant path in a multipath system fails, some drives are marked offline.
  • Fixed an issue which could cause hangs when replacing a controller with an existing configuration.
  • Fixed several grammatical and formatting issues.
  • Fixed an issue where importing foreign configuration under CTRL-R could cause the firmware to crash.
  • Fixed an issue where an unresponsive SEP could result in a "greater than 122 devices detected" message.
  • Fixed an issue where the, after a RAID 6 is reconstructed as a RAID 5, the configuration is reported incorrectly upon reboot.
  • Fixed an issue which could result in incorrect data on the drives when I/O is run while a capacity expansion is in progress.
  • Fixed an issue that could cause a hang when an enclosure is power cycled while I/O is running.
  • Fixed an issue where, if a physical drive became invalid during a rebuild to that drive, the rebuild would pause, rather than fail.
  • Fixed an issue where Battery Warning messages would appear, even when disabled.
  • Fixed an issue which resulted in "Unexpected sense" messages in the log with SATA drives.
  • Fixed an issue where Cache Data could be lost during a power failure.
  • Fixed an issue where not all SATA drives were found during discovery.
  • Fixed an issue which may result in a firmware hang during a reconstruction operation.
  • Fixed an issue where the firmware would continue to try to communicate with a bad drive. The symptom of this issue is a drive where the status light is blinking amber and the activity light is solid green.
  • Fixed an issue where an enclosure reboot could, very rarely, cause a condition where the driver sends a Kill Adapter signal.
  • Fixed an issue where, if a medium error is encountered on a source drive during a rebuild, the bad block may not get marked as bad.
  • Fixed an issue where running in degraded mode with medium errors could cause the firmware to hang.
  • Fixed an issue where running heavy I/O on daisy-chained enclosures for an extended period of time could cause a hang.
  • Fixed an issue where, with some hardware, the configuration is not found within the timeout time on a cold reboot. This leads to a prompt to import configuration, after which, the configuration is seen correctly.
  • Fixed an issue with I2C LED support.
  • Fixed an issue where the write cache policy would unexpectedly change from write back to write through, then would change back after about a minute.
  • Fixed an issue where, if a cable is pulled in a multipath environment, the alternate path is sometimes not followed.
  • Fixed an error in the ECC error logging which can cause a memory leakage.
  • Fixed an issue where the firmware will hang if discovery does not complete in two minutes.
  • Fixed an issue where full initialization of a large number of SATA drives would cause timeouts.
  • Fixed several LED issues with I2C backplanes.
  • Fixed an issue sensing dual I2C backplanes in a multipath environment.

Functionality:

  • Added support for 64 virtual disks per array.
  • Added support for expanded RAID 1, a form of RAID 1E which supports even numbers of drives.
  • Added the ability to hot-swap a battery.
  • Added the ability to manually initiate the battery learn cycle.
  • Added multipathing support for SATA drives.
  • Added the ability to enable or disable NCQ from the CLI or WebBIOS.
  • Added the copyback feature, which is used when a drive goes defunct and the array rebuilds to a hotspare. Copyback allows the hotspare to rebuild to a new drive that is inserted to replace the defunct drive.
  • Clarified several log event messages.
  • Implemented load balancing when multipath SAS is used.
  • Added logging for some events that were not previously logged.
  • Increased the PHY count from 512 to 640 to support 21 enclosures.

Version 8.0.1-0036

  • Initial release

Off

Document Location

Worldwide

Operating System

System x:Operating system independent / None

[{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QU03FLY","label":"System x->System x3610->7942"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
01 July 2009

UID