A fix is available
APAR status
Closed as program error.
Error description
Message CQM1055E REASON=xxxxxxxx may be incorrectly issued. In some cases the CQM1055E message may be issued after a temporary storage constraint issue has occurred. In these cases the storage constraint has been resolved and is no longer occurring but the message may continue to be generated. This problem only occurs in environments where SQL statements greater than 64K are being collected.
Local fix
THE FOLLOWING WORK AROUND SHOULD ONLY BE USED WITH THE RECOMMENDATION IBM SUPPORT Add parameter 64KSEGMENTS(2048) to the CQMPARMS file and recycle the CQM collector
Problem summary
**************************************************************** * USERS AFFECTED: Users of DB2 Query Monitor. * **************************************************************** * PROBLEM DESCRIPTION: Message CQM1055E REASON=xxxxxxxx may * * be incorrectly issued. In some cases * * the CQM1055E message may be issued * * after a temporary storage constraint * * issue has occurred. In these cases * * the storage constraint has been * * resolved and is no longer occurring * * but the message may continue to be * * generated. This problem only * * occurs in environments where SQL * * statements greater than 64K are * * being collected. * **************************************************************** * RECOMMENDATION: APPLY the PTF. * **************************************************************** Code has been changed to correct this condition.
Problem conclusion
APPLY the PTF.
Temporary fix
Comments
APAR Information
APAR number
PK89210
Reported component name
DB2 QUERY MONIT
Reported component ID
5655E6701
Reported release
230
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2009-06-18
Closed date
2009-07-30
Last modified date
2009-09-28
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK48844
Modules/Macros
CQMISMPX
Fix information
Fixed component name
DB2 QUERY MONIT
Fixed component ID
5655E6701
Applicable component levels
R230 PSY UK48844
UP09/08/07 P F908
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.