PH61979: WRONGLY GENERATED ERROR "IGYPS5306-U AN INTERNAL COMPILER ERROR OCCURRED. CONDITION (GITTYPCD=GITTYPCV&GITC1ST=ON) FAILED AT..."

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • A program compiles successfully using COBOL V6.2 but it fails in
    V6.3/V6.4 with the following messages:
    IGYPS5125-U   The compilation was terminated due to a compiler
    error in phase id:  "IGYCPSCN".
    IGYPS5306-U   An internal compiler error occurred.  Condition
    (GITTYPCD=GITTYPCV&GITC1ST=ON) failed at IGYQPR04-32768
    
    ADDITIONAL SYMPTOMS:
    IGYPS5125-U, IGYPS5306-U
    

Local fix

  • BYPASS/CIRCUMVENTION:
    None
    
    RECOVERY ACTION:
    Apply PTF
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Enterprise COBOL V6.4 compiling     *
    *                 programs that contain a SPECIAL-NAMES        *
    *                 paragraph that defines one or more 1-byte    *
    *                 user-programmable status indicator (UPSI)    *
    *                 switches.                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION: Compiler abort with message:            *
    *                                                              *
    *                      IGYPS5125-U   The compilation was       *
    *                      terminated due to a compiler error      *
    *                      in phase id:  "IGYCPSCN".               *
    *                                                              *
    *                      IGYPS5201-U   Internal compiler error   *
    *                      code "QPR04-00" occurred.               *
    ****************************************************************
    * RECOMMENDATION: Apply the IBM provided PTF and rerun the     *
    *                 compile.                                     *
    ****************************************************************
    There was a null pointer dereference in the compiler when
    handling a SPECIAL-NAMES paragraph with one or more 1-byte
    user-programmable status indicator (UPSI) switches.
    

Problem conclusion

  • The compiler was updated so that the null pointer dereference is
    avoided when there is a SPECIAL-NAMES paragraph with one or more
    1-byte user-programmable status indicator (UPSI) switches.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH61979

  • Reported component name

    ENT COBOL FOR Z

  • Reported component ID

    5655EC600

  • Reported release

    640

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2024-06-21

  • Closed date

    2024-06-21

  • Last modified date

    2024-07-01

  • APAR is sysrouted FROM one or more of the following:

    PH61120

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • IGY8RWTU IGYCASMB IGYCCBE  IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN
    IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4
    IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT
    IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8
    IGYCJA$D IGYCJA$R IGYCJBLD IGYCJDM1 IGYCJDM2 IGYCJDM3 IGYCJDM4
    IGYCJDM5 IGYCJDM6 IGYCJDMB IGYCJDMJ IGYCJDMR IGYCJDN1 IGYCJDN2
    IGYCJDN3 IGYCJDNB IGYCJDNJ IGYCJDNR IGYCJGEN IGYCLIBR IGYCLSTR
    IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN
    IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT  IGYCSCAN
    IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5
    IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV   IGYEQCWI IGYMSGE
    IGYMSGK  IGYMSGT  IGYQCBE  IGYQSPLT IGYZQEN6 IGYZQENU IGYZQJP6
    IGYZQJPN
    

Fix information

  • Fixed component name

    ENT COBOL FOR Z

  • Fixed component ID

    5655EC600

Applicable component levels

  • R640 PSY UI97420

       UP24/06/27 P F406

  • R641 PSY UI97421

       UP24/06/27 P F406

  • R642 PSY UI97422

       UP24/06/27 P F406

  • R64H PSY UI97423

       UP24/06/27 P F406

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.