A fix is available
APAR status
Closed as program error.
Error description
A program compiles successfully using COBOL V6.2 but it fails in V6.3/V6.4 with the following messages: IGYPS5125-U The compilation was terminated due to a compiler error in phase id: "IGYCPSCN". IGYPS5306-U An internal compiler error occurred. Condition (GITTYPCD=GITTYPCV&GITC1ST=ON) failed at IGYQPR04-32768 ADDITIONAL SYMPTOMS: IGYPS5125-U, IGYPS5306-U
Local fix
BYPASS/CIRCUMVENTION: None RECOVERY ACTION: Apply PTF
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL V6.4 compiling * * programs that contain a SPECIAL-NAMES * * paragraph that defines one or more 1-byte * * user-programmable status indicator (UPSI) * * switches. * **************************************************************** * PROBLEM DESCRIPTION: Compiler abort with message: * * * * IGYPS5125-U The compilation was * * terminated due to a compiler error * * in phase id: "IGYCPSCN". * * * * IGYPS5201-U Internal compiler error * * code "QPR04-00" occurred. * **************************************************************** * RECOMMENDATION: Apply the IBM provided PTF and rerun the * * compile. * **************************************************************** There was a null pointer dereference in the compiler when handling a SPECIAL-NAMES paragraph with one or more 1-byte user-programmable status indicator (UPSI) switches.
Problem conclusion
The compiler was updated so that the null pointer dereference is avoided when there is a SPECIAL-NAMES paragraph with one or more 1-byte user-programmable status indicator (UPSI) switches.
Temporary fix
Comments
APAR Information
APAR number
PH61979
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
640
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-06-21
Closed date
2024-06-21
Last modified date
2024-07-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCJBLD IGYCJDM1 IGYCJDM2 IGYCJDM3 IGYCJDM4 IGYCJDM5 IGYCJDM6 IGYCJDMB IGYCJDMJ IGYCJDMR IGYCJDN1 IGYCJDN2 IGYCJDN3 IGYCJDNB IGYCJDNJ IGYCJDNR IGYCJGEN IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYQSPLT IGYZQEN6 IGYZQENU IGYZQJP6 IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R640 PSY UI97420
UP24/06/27 P F406
R641 PSY UI97421
UP24/06/27 P F406
R642 PSY UI97422
UP24/06/27 P F406
R64H PSY UI97423
UP24/06/27 P F406
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"640","Line of Business":{"code":"LOB70","label":"Z TPS"}}]
Document Information
Modified date:
02 July 2024