APAR status
Closed as program error.
Error description
Migrated v5 post response extension DataPower rules are run in the API Gateway as a v5 emulated user defined policy. Unlike migrated v5 user defined policies which are not provided the current message.body in the INPUT context, the migrated post response rule requires the current message.body in the INPUT context which the v5 emulation framework was not providing. The end result was the called rule results action returned a buffer of an empty XML nodeset provided instead in INPUT. The buffer equivalent of the empty XML nodeset is an XML declarative only which when parsed resulted in a parse error.
Local fix
Problem summary
Migrated v5 post response extension DataPower rules are run in the API Gateway as a v5 emulated user defined policy. Unlike migrated v5 user defined policies which are not provided the current message.body in the INPUT context, the migrated post response rule requires the current message.body in the INPUT context which the v5 emulation framework was not providing. The end result was the called rule results action returned a buffer of an empty XML nodeset provided instead in INPUT. The buffer equivalent of the empty XML nodeset is an XML declarative only which when parsed resulted in a parse error.
Problem conclusion
Fix is available in10.5.0.12, 10.6.0.0 For a list of the latest fix packs available, please see: https://www.ibm.com/support/pages/node/83105
Temporary fix
Comments
APAR Information
APAR number
IT46116
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
A0X
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-05-07
Closed date
2024-06-20
Last modified date
2024-06-20
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateways"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A0X","Line of Business":{"code":"LOB67","label":"IT Automation \u0026 App Modernization"}}]
Document Information
Modified date:
20 June 2024