APAR status
OPEN
Error description
You migrate to CICS TS 6.1 and start receiving ABENDATCE which means- no tioa was supplied for a write request. Looking at a system dump from the ATCE abend, CICS trace shows the abend is occurring on the first EXEC CICS RECEIVE-TC command issued by the task. Here are the trace entries: AP 00E1 EIP ENTRY RECEIVE-TC AP FD01 ZARQ ENTRY APPL_REQ TCTTE(22D33AB0) READ WAIT READBUF TRANSPARENT AP 2000 PCPG ENTRY - ABEND Looking at the code in DFHZARQ at the 6.1 level, there is new code added to check for the presence of a Terminal Input Ouput Area or TIOA, if auto journaling is turned on. In this case, there is no TIOA which leads to the ATCE abend. This check for the TIOA was not made in the prior release of CICS. Additional symptoms: KIXREVRJL DBUG terminal initiated journal attributes autojournal
Local fix
turn off journaling in the terminal profile associated with the transaction
Problem summary
Problem conclusion
Temporary fix
Comments
APAR Information
APAR number
PH60509
Reported component name
CICS TS Z/OS V6
Reported component ID
5655YA100
Reported release
400
Status
OPEN
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-03-22
Closed date
Last modified date
2024-04-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"D10","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
04 April 2024