IBM Support

Guardium 12.0p6003 is causing instability on physical M7 (SR630 v2) Guardium Appliances

Flashes (Alerts)


Abstract

Installing Guardium security patch 12.0p6003 on appliances can cause instability. While issues have only been reported on physical M7 (SR630 v2) appliances it has been discovered that the version of kernel and glibc libraries shipped with p6003 contain a defect which can result in frequent server reboots. As a result p6003 has been pulled from Fix Central and has been replaced with an updated p6004 release which is now available.

Content

Environments affected
Physical M7 (SR630 v2) appliances with p6003 applied. 
Remediation
IBM is aware of the issue and working on a fix which will be placed on Fix Central once complete.  If p6003 has been applied to a system it is recommended that the appliance be rebuilt.

[{"Type":"MASTER","Line of Business":{"code":"LOB24","label":"Security Software"},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSWKA4","label":"IBM Security Guardium Appliances"},"ARM Category":[{"code":"a8m0z000000Gp0JAAS","label":"APPLIANCE"},{"code":"a8m0z000000Gp0WAAS","label":"HARDWARE"}],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"All Versions"}]

Document Information

Modified date:
19 April 2024

UID

ibm17144140