A fix is available
APAR status
Closed as program error.
Error description
- During shutdown the Publisher API PC routine CEXPUBMN loops issuing the message: CEX5029I CEX Publisher API waiting for 1 PC routine(s) to end before closing. - After Publisher API client abends with: CEX7206E CEXPAPI REQUEST=READASYN ended with R15=00000008 R0=00000047 REASON=CEXMAPI ESTAE subsequently restarting the Publisher API client results in: CEX7206E CEXPAPI REQUEST=CONNECT ended with R15=00000010 R0=00000057 REASON=MTT_SWPLOCK not obtained
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of IMS Connect Extensions V3.1 * **************************************************************** * PROBLEM DESCRIPTION: Problems in Publisher API error * * recovery. * **************************************************************** 1. During shutdown the Publisher API module CEXPUBMN loops issuing the message: CEX5029I CEX Publisher API waiting for 1 PC routine(s) to end before closing 2. After Publisher API client abends with: CEX7206E CEXPAPI REQUEST=READASYN ended with R15=00000008 R0=00000047 REASON=CEXMAPI ESTAE subsequently restarting the Publisher API client results in: CEX7206E CEXPAPI REQUEST=CONNECT ended with R15=00000010 R0=00000057 REASON=MTT_SWPLOCK not obtained
Problem conclusion
1. CEXPUBMN is corrected so that so that after waiting 10 seconds shutdown continues. 2. CEXPC01 is corrected.
Temporary fix
Comments
APAR Information
APAR number
PH59947
Reported component name
IMS CONNECT EXT
Reported component ID
5655K4800
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-02-21
Closed date
2024-04-29
Last modified date
2024-05-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI96712
Modules/Macros
CEXPC01 CEXPUBMN
Fix information
Fixed component name
IMS CONNECT EXT
Fixed component ID
5655K4800
Applicable component levels
R310 PSY UI96712
UP24/05/02 I 1000
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.