Maximo Asset Management 7.6.1.3 interim fixes incorporate Maximo Integration Framework (MIF) fixes, previously released in separate IBM Installation Manager packages.
APAR | Application Name | Description |
IJ49595 | Inventory usage | The "Shelf Life" value is lost when a Lotted Item is transferred using Inventory Usage. |
DT243499 | Inspection | With Maximo Application Suite 8.10, new functionality was added to the Inspection Application introduced, MVI analysis. The component used to view the MVI result is the graphite-common-solution-components (gcsc). Originally, the Inspection app was built with gcsc-2.0.13, but this component is incompatible with the Config Tool (MAF 8_10_6). It was necessary to upgrade the gcsc to a version that is compatible with the Config Tool. Maximo Asset Management clients must install TPAE 7.6.1.3 interim fix 016 or later. |
IJ49537 | Login | A failed login attempt results in the error "The server has encountered an unknown error." rather than BMXAA7901E - "You cannot log in at this time. Contact the system administrator.". |
DT237643 | Graphical Work Week | Work Order Scheduled Start and End dates are not updated when changed in the Graphical Work Week view. |
DT256781 | Graphical Assignment | The Work Order marker does not appear on a Map when the record has a Service Address. |
IJ49481 | System UI | The Calendar Button in SQL Expression Builder does not work. |
IJ49458 | System UI | In Inspections, cannot enter a time in "HH:mm:ss" format. |
IJ38777 | Location | If a Location's status is changed to a synonym of the current status, a date prior to the last status change can be used. |
IJ46690 | Email Listeners | E-mail Listener fails for certain email address display name encodings. |
IJ49189 | Move/Modify Assets | Moving multiple Rotating Assets which are not in a Location can result in error BMXAA4211E or BMXAA8229W. |
IJ45556 | Inventory usage | Changing an Inventory Usage record which has an Item with a cost type of STANDARD on two lines to Complete status results in error BMXAA8229W. |
IJ36219 | Database configuration | Increasing the number of Tax types in Database Configuration when audit is enabled for that object results in error BMXAA0596E - "A row cannot be added because this object is not editable.". |
IJ49030 | Classifications | Attributes marked as mandatory in the Classifications application are not displayed as mandatory on the Specification tab of the corresponding application. |
IJ39413 | Invoices | When an Invoice for Service is reversed and the Service was not first received, an error is thrown approving the new Invoice. |
IJ47793 | System UI | The "Standard Start Center" link that displays when you click "Mobile Start Center" is difficult to distinguish against the background. |
IJ48645 | Inventory usage | Issue transactions are generated with "???" in GLDEBITACCT. |
IJ44362 | Inventory usage | GL Debit Account value from Reservation is not populated on Inventory Usage record when "Create Remaining Usage Lines" action is used. |
IJ49036 | System UI | When System Properties mxe.webclient.skin = tivoli13 and mxe.webclient.verticalLabels = 1, the label is very close to the check box. |
IJ48902 | Work Order Tracking | Changing the status of a closed Work Order to a synonym value results in a database error. |
IJ48890 | Classifications | Changes to the data type of an Attribute in the Classification application are not reflected in the Assets application. |
IJ48875 | Email Listeners | E-mail Listener cannot process an attachment of type ".msg". |
IJ48876 | Report | BIRT Inventory ROP Analysis report has incorrect values for "New ROP Value" and "New Safety Stock Value". The fix requires the updated inventory_rop_transdate.rptdesign. |
IJ48747 | Location | In the Create Service Request application, clicking the Select Value option on the Location field results in error BMXAA2661E - "Location LOCZBC is not a valid location.". |
IJ48739 | System UI | When the date format is set to dd/MMM/yyyy and the user's locale is en_AU or en_GB, picking a date in September results in error BMXAA4144E. |
IJ48283 | Item Master | Adding a new item results in errors BMXAA7136E - "Validation failed when the database default values were set. See the associated message for more information." and BMXAA7831I - "Do you want to apply the tax-exempt status to the organization level for the item, and to the vendor level for the item?.". |
IJ47091 | Inventory | The "Disallow Negative Current Balance" and "Disallow Negative Available Balance" settings do not get applied in all scenarios. |
IJ47792 | Item Assembly Structures | In the Assets application, in the "Apply Item Assembly Structure" dialog, selecting the Move to menu option in the Belongs to field causes error BMXAA4107E. |
IJ35576 | Receiving | Receiving a large quantity of Rotating Assets as a Direct Issue to an operating location results in error BMXAA1771E - "This asset already exists. Please enter new asset.". |
IJ46181 | Integration | Creating a Location with a hierarchy with the API results in error BMXAA4214E - "An unknown error has occurred.". |
IJ46151 | Integration | Using MIF or Application Import to update serialnum field for assets that have a groupname results in error BMXAA8665W - "Do you want to allow sequence number duplication?". |
IJ45853 | Report | Direct Print with Attachment doesn't work when attachment is located in UNC path and OS of Maximo application server is not Windows. |
IJ37751 | Inventory | Incorrect Current Balance shown in Message Tracking application. |
IBM Control Desk
- IBM Control Desk 7.6.1.3 and 7.6.1.4 use Tivoli's process automation engine 7.6.1.2.Apply interim fixes for Maximo Asset Management 7.6.1.2 to IBM Control Desk 7.6.1.3 and 7.6.1.4.
- IBM Control Desk 7.6.1.5 uses Tivoli's process automation engine 7.6.1.3. This interim fix can be applied to IBM Control Desk 7.6.1.5.
Related Information
[{"Line of Business":{"code":"LOB59","label":"Sustainability Software"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSLKT6","label":"IBM Maximo Asset Management"},"ARM Category":[{"code":"a8m50000000CbP7AAK","label":"Install-\u003EFixpack"}],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.6.1"},{"Type":"MASTER","Line of Business":{"code":"LOB59","label":"Sustainability Software"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSWT9A","label":"IBM Control Desk"},"ARM Category":[{"code":"a8m500000008b3TAAQ","label":"Miscellaneous Category (Portal, UI, Maximo, Install)"}],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.6.1"}]