A fix is available
APAR status
Closed as program error.
Error description
IGYCB7104-U Internal error, Failed assertion on opts/ValuePropagation.cpp:4580
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL 6.2 compiling * * programs at OPT(1|2) where the last * * statement in a paragraph is a "GO TO ... * * DEPENDING ON" statement, which is followed * * immediately by a procedure the "GO TO" * * goes to, and this procedure is not the * * first procedure specified in the "GO TO" * * statement. * **************************************************************** * PROBLEM DESCRIPTION: Compiler abends with message * * "MSGIGYCB7104-U Internal error, Failed * * assertion on opts/ValuePropagation.cpp: * * 4580" * **************************************************************** * RECOMMENDATION: Apply the provided PTF * **************************************************************** The compiler's internal state may become inaccurate if the final statement in a paragraph is a "GO TO ... DEPENDING ON" statement, and is followed immediately by a procedure the GO TO goes to, and this procedure is not the first procedure specified in the GO TO statement. When the compiler detects that its internal state is inaccurate, it abends.
Problem conclusion
The compiler was fixed to update its internal state correctly.
Temporary fix
Comments
APAR Information
APAR number
PH59419
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
620
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-01-26
Closed date
2024-01-26
Last modified date
2024-02-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI95431 UI95432 UI95433
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBH IGYCLIBO IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYZQDRV IGYZQENU IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R620 PSY UI95431
UP24/02/01 P F401
R621 PSY UI95432
UP24/02/01 P F401
R622 PSY UI95433
UP24/02/01 P F401
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"620","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
01 February 2024