A fix is available
APAR status
Closed as program error.
Error description
IGYCB7104-U Internal error, Failed assertion on opts/ValuePropagation.cpp:4580
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL 6.4 compiling * * programs at OPT(1|2) where the last * * statement in a paragraph is a "GO TO ... * * DEPENDING ON" statement, which is followed * * immediately by a procedure the "GO TO" goes * * to, and this procedure is not the first * * procedure specified in the "GO TO" * * statement. * **************************************************************** * PROBLEM DESCRIPTION: Compiler abends with message * * "MSGIGYCB7104-U Internal error, * * Failed assertion on * * opts/ValuePropagation.cpp:4580" * **************************************************************** * RECOMMENDATION: Apply the provided PTF * **************************************************************** The compiler's internal state may become inaccurate if the final statement in a paragraph is a "GO TO ... DEPENDING ON" statement, and is followed immediately by a procedure the GO TO goes to, and this procedure is not the first procedure specified in the GO TO statement. When the compiler detects that its internal state is inaccurate, it abends.
Problem conclusion
The compiler was fixed to update its internal state correctly.
Temporary fix
Comments
APAR Information
APAR number
PH58661
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
640
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-12-08
Closed date
2023-12-08
Last modified date
2024-01-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCJBLD IGYCJGEN IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOB2 IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYQSPLT IGYZQEN6 IGYZQENU IGYZQJP6 IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R640 PSY UI94827
UP23/12/15 P F312
R641 PSY UI94828
UP23/12/15 P F312
R642 PSY UI94829
UP23/12/15 P F312
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"640","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
02 January 2024