APAR status
Closed as program error.
Error description
Transaction Rollback events are not getting generated when monitoring is configured using a monitoring profile with the event source address set to 'transaction.all'.
Local fix
Problem summary
**************************************************************** USERS AFFECTED: All users of IBM App Connect Enterprise V12.0 who uses monitoring profiles. Platforms affected: MultiPlatform **************************************************************** PROBLEM DESCRIPTION: A message flow configured with a monitoring profile, where the event source address is set to 'transaction.all' and the unitOfWork property is not set to 'independent', is expected to emit transaction start/rollback events for all input nodes in the flow whenever a transaction gets rolled back. However, it has been observed that the Transaction Rollback events are not getting generated for any of the input nodes.
Problem conclusion
The product has been modified so that the transaction rollback events are generated successfully for the input nodes. --------------------------------------------------------------- The fix is targeted for delivery in the following PTFs: Version Maintenance Level v12.0 12.0.11.0 The latest available maintenance can be obtained from: http://www-01.ibm.com/support/docview.wss?rs=849&uid=swg27006041 If the maintenance level is not yet available,information on its planned availability can be found on: http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27006308 ---------------------------------------------------------------
Temporary fix
Comments
APAR Information
APAR number
IT44730
Reported component name
APP CONNECT ENT
Reported component ID
5724J0560
Reported release
C00
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-10-12
Closed date
2023-11-23
Last modified date
2023-11-23
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
APP CONNECT ENT
Fixed component ID
5724J0560
Applicable component levels
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSDR5J","label":"IBM App Connect Enterprise"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"C00","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date: