IBM Support

PH58256: ADMIN TOOL: -551 ERROR ON SYSIBM.SYSENVIRONMENT

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • DESCRIPTION:  When option T or V are selected on panel ADB21 or
    line command 'ENV' is entered on panel ADB21T, SQLCODE = -551
    can occur.
    
    
    Root cause:
    
    
    The following statement is missing from the TCz job template
    ADBSETUP when TCz parameter "GRANT SELECT ON remaining tables
    TO" is used:
    
    
    GRANT SELECT ON TABLE SYSIBM.SYSENVIRONMENT TO ....
    

Local fix

  • The grant can be issued using SPUFI
    
    GRANT SELECT ON TABLE SYSIBM.SYSENVIRONMENT TO ....
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Db2 Administration Tool for z/OS    *
    *                 and IBM Tools Customizer for z/OS            *
    ****************************************************************
    * PROBLEM DESCRIPTION: SQLCODE = -551 can occur when option    *
    *                      T or V are selected on panel ADB21.     *
    ****************************************************************
    When option T or V are selected on panel ADB21 or line command
    'ENV' is entered on panel ADB21T, the following error can occur:
    DSNT408I SQLCODE = -551, ERROR: BR37788 DOES NOT HAVE THE
    PRIVILEGE TO PERFORM OPERATION SELECT ON OBJECT
    SYSIBM.SYSENVIRONMENT
    

Problem conclusion

  • The problem has been resolved where TCz job template ADBSETUP
    will ensures the following GRANT statement is generated when
    TCz parameter "GRANT SELECT ON remaining tables TO" is used:
    GRANT SELECT ON TABLE SYSIBM.SYSENVIRONMENT TO ....
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH58256

  • Reported component name

    DB2 ADMIN TOOL

  • Reported component ID

    568851500

  • Reported release

    D10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-11-16

  • Closed date

    2024-02-02

  • Last modified date

    2024-03-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI95535 UI95536

Modules/Macros

  • ADB$$PRM ADBPLANS ADBSETUP
    

Fix information

  • Fixed component name

    DB2 ADMIN TOOL

  • Fixed component ID

    568851500

Applicable component levels

  • RC10 PSY UI95535

       UP24/02/07 P F402

  • RD10 PSY UI95536

       UP24/02/07 P F402

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.