IBM Support

PH58091: MONSTATUS OF A MQMONTITOR NOT STOPPING AS EXPECTED

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • After a CEMT SET MQM() STOP command  CEMT INQUIRE MQMON still
    shows the mqmonitor as started.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICS Users.                              *
    ****************************************************************
    * PROBLEM DESCRIPTION: An MQMonitor is being stopped, however  *
    *                      an inquire of that MQMonitor shows its  *
    *                      state as started.                       *
    ****************************************************************
    When issuing a CEMT SET MQMONITOR STOPPED, DFHMQTM is called
    and sets the monstatus bit to indicate it is stopping.
    To check that the MQMonitor has been stopped successfully, an
    INQUIRE MQMONITOR is issued and again DFHMQTM is called but sees
    that the CKTI transaction is still active and incorrectly resets
    the monstatus bit indicating the MQMonitor is started.
    

Problem conclusion

  • DFHMQTM has been changed to ensure that an MQMOnitor in a
    stopping state does not have its status altered back to started.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH58091

  • Reported component name

    CICS TS Z/OS V6

  • Reported component ID

    5655YA100

  • Reported release

    400

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-11-09

  • Closed date

    2023-12-06

  • Last modified date

    2024-01-02

  • APAR is sysrouted FROM one or more of the following:

    PH57257

  • APAR is sysrouted TO one or more of the following:

    UI94740

Modules/Macros

  • DFHMQTM
    

Fix information

  • Fixed component name

    CICS TS Z/OS V6

  • Fixed component ID

    5655YA100

Applicable component levels

  • R400 PSY UI94740

       UP23/12/07 P F312

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.1","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date: